[29] Special analog input
Communi
Title
Function
cation No
Acceleration/deceleration

0650
base frequency adjustment
0651
Upper-limit frequency adjustment 0: Invalid,1: VI/II,2: RR


0652
Acceleration time adjustment 0: Invalid,1: VI/II,2: RR
0653
Deceleration time adjustment 0: Invalid,1: VI/II,2: RR


0654
Manual torque boost adjustment 0: Invalid,1: VI/II,2: RR
[30] Over-ride
Communi
Title
Function
cation No
Over-ride addition input

0660
selection
0661
Over-ride multiplication input selection 0: Disabled,1: VI/II,2: RR,3: RX,4: RX2,5: 

[31] Meter output (1/2)
Communi
Title
Function
cation No

0670
AM terminal meter selection

0671
AM terminal meter adjustment
0672
Optional analog terminal #1 meter selection 0∼32


0673
Optional analog terminal #1 meter adjustment
0674
Optional analog terminal #2 meter selection 0∼32


0675
Optional analog terminal #2 meter adjustment
0676
FP terminal meter selection


0677
FP terminal meter adjustment
0678
Optional analog terminal #1 meter offset -10.0∼60.0


0679
Optional analog terminal #2 meter offset -10.0∼60.0
0680
Optional analog terminal sign selection

(Reference section): Refer to the inverter's individual manual.
Adjustment range
0: Invalid,1: VI/II,2: RR
Adjustment range
0: Disabled
1: VI (voltage input)/II (current input)
2: RR (volume/voltage input)
3: RX (voltage input)
4: RX2 (voltage input) (optional)
5: Operating panel input
6: Binary/BCD input
7: Common serial communication option(FA01)
8: Serial communication RS485(FA05)
9: Communication add-on cassette option(FA07)
10: Up-down frequency
11: Pulse input #1 (optional)
Adjustment range
0∼32
0∼32
1.00∼43.20
0∼3
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Enabled
●/●
0
Enabled
●/●
0
Enabled
●/●
0
Enabled
●/●
0
Enabled
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Enabled
●/●
0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
2(output
Enabled
●/●
current)
Enabled
●/●
4
Enabled
●/●
Enabled
●/●
5
Enabled
●/●
Enabled
●/●
0
Enabled
●/●
0.01/0.001
3.84
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
0.1/0.1
0.0
Enabled
●/●
0
Enabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.26
6.26
6.26
6.26
6.26
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.27
6.27
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
●/●
−/●
5.4
●/●
−/●
5.4
●/●
−/●
●/●
−/●
●/●
−/●
●/●
−/●
6.28.3
●/●
−/●
●/●
−/●
6.28.3
●/●
−/●
●/●
−/●
●/●
−/●