Toshiba TOSVERT VF-P7 Instruction Manual page 210

Inverter for fan and pump applications
Hide thumbs Also See for TOSVERT VF-P7:
Table of Contents

Advertisement

[11] Jumper frequency
Communi
Title
Function
cation No

0270
Jump frequency #1
0271
Jump frequency band #1


0272
Jump frequency #2
0273
Jump frequency band #2

0274
Jump frequency #3

0275
Jump frequency band #3

0276
Object of jump frequency process 0: Process amount, 1: Output frequency

[12] Preset speed operation frequency (8- to 15-stage speed)
Communi
Title
Function
cation No
0287
Preset-speed #8


0288
Preset-speed #9
0289
Preset-speed #10


0290
Preset-speed #11
0291
Preset-speed #12


0292
Preset-speed #13
0293
Preset-speed #14


0294
Preset-speed #15
[13] PWM carrier frequency
Communi
Title
Function
cation No

0300
PWM carrier frequency
(*1)Upper limits differ by applicable motor capacity. For details, refer to 6.12.
Carrier frequency is automatically limited to less than 10kHz when operation frequency is more than 130Hz.
[14] Tripless intensification setup (1/2)
Communi
Title
Function
cation No
0301
Auto-restart

Regenerative power ride-through
0302

control / Deceleration stop
0303
Retry selection


0304
Dynamic braking mode selection 0: Disabled, 1: Enabled/overload detection enabled
0305
Over-voltage stall protection

Base frequency voltage #1
0306

(output voltage adjustment)
Adjustment range
0.0∼ [Hz]
0.0∼30.0 [Hz]
0.0∼ [Hz]
0.0∼30.0 [Hz]
0.0∼ [Hz]
0.0∼30.0 [Hz]
Adjustment range
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
Adjustment range
0.5∼15.0(8.0, 5.0) [kHz] (*1)
Adjustment range
0: Disabled, 1: Enabled(at power failure),
2: Enabled(at ST ON/OFF), 3: Enabled(1+2)
0: OFF, 1: ON, 2:ON(Deceleration stop)
0: Disabled, 1 to 10 times
0: Enabled, 1: Disabled,
2: Enabled (Forced quick deceleration)
0.0∼600.0 [V]
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.1/0.001
See J-28 Disabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Enabled
●/●
0
Enabled
●/●
0
Enabled
●/●
See J-28
Enabled
●/●
0
Enabled
●/●
0.1/0.1
See J-28
Enabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.10
6.10
6.10
6.10
6.10
6.10
6.10
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
5.14
5.14
5.14
5.14
5.14
5.14
5.14
5.14
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
●/●
−/●
6.12
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.13.1
●/●
−/●
6.13.2
−/−
−/−
6.13.3
●/●
−/●
●/●
−/●
6.13.4
6.13.5
●/●
−/●
6.13.6
●/●
−/●