[11] Jumper frequency
Communi
Title
Function
cation No
0270
Jump frequency #1
0271
Jump frequency band #1
0272
Jump frequency #2
0273
Jump frequency band #2
0274
Jump frequency #3
0275
Jump frequency band #3
0276
Object of jump frequency process 0: Process amount, 1: Output frequency
[12] Preset speed operation frequency (8- to 15-stage speed)
Communi
Title
Function
cation No
0287
Preset-speed #8
0288
Preset-speed #9
0289
Preset-speed #10
0290
Preset-speed #11
0291
Preset-speed #12
0292
Preset-speed #13
0293
Preset-speed #14
0294
Preset-speed #15
[13] PWM carrier frequency
Communi
Title
Function
cation No
0300
PWM carrier frequency
(*1)Upper limits differ by applicable motor capacity. For details, refer to 6.12.
Carrier frequency is automatically limited to less than 10kHz when operation frequency is more than 130Hz.
[14] Tripless intensification setup (1/2)
Communi
Title
Function
cation No
0301
Auto-restart
Regenerative power ride-through
0302
control / Deceleration stop
0303
Retry selection
0304
Dynamic braking mode selection 0: Disabled, 1: Enabled/overload detection enabled
0305
Over-voltage stall protection
Base frequency voltage #1
0306
(output voltage adjustment)
Adjustment range
0.0∼ [Hz]
0.0∼30.0 [Hz]
0.0∼ [Hz]
0.0∼30.0 [Hz]
0.0∼ [Hz]
0.0∼30.0 [Hz]
Adjustment range
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
∼ [Hz]
Adjustment range
0.5∼15.0(8.0, 5.0) [kHz] (*1)
Adjustment range
0: Disabled, 1: Enabled(at power failure),
2: Enabled(at ST ON/OFF), 3: Enabled(1+2)
0: OFF, 1: ON, 2:ON(Deceleration stop)
0: Disabled, 1 to 10 times
0: Enabled, 1: Disabled,
2: Enabled (Forced quick deceleration)
0.0∼600.0 [V]
Sensorless vector/vector with sensor (●valid, −:invalid)
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0
Enabled
−
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
0.01/0.01
0.0
Enabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0.1/0.001
See J-28 Disabled
●/●
Min. unit (panel/
Default
Write during
Speed
communication)
setting
running
control
0
Enabled
−
●/●
0
Enabled
−
●/●
0
Enabled
−
●/●
−
See J-28
Enabled
●/●
0
Enabled
−
●/●
0.1/0.1
See J-28
Enabled
●/●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
−
−
●
6.10
6.10
−
−
●
−
−
●
6.10
6.10
−
−
●
6.10
−
−
●
6.10
−
−
●
6.10
−
−
●
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
5.14
−
−
●
−
−
●
5.14
5.14
−
−
●
−
−
●
5.14
5.14
−
−
●
−
−
●
5.14
5.14
−
−
●
−
−
●
5.14
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
●/●
−/●
●
6.12
Vector control
V/f
Reference
Torque
Position
Constant
section
control
control
6.13.1
●/●
−/●
●
6.13.2
−/−
−/−
●
6.13.3
●/●
−/●
●
●/●
−/●
●
6.13.4
6.13.5
●/●
−/●
●
6.13.6
●/●
−/●
●