Replacement Of Carbon Brushes; Lubrication - Craftsman 320.17541 Operator's Manual

9.5 amp 1 3/4 peak hp fixed base router
Table of Contents

Advertisement

REPLACEMENT
OF CARBON BRUSHES (Fig. 20)
Replacement brush sets are available through Sears Parts and Repair Centers°
!o Unplug the router motor before inspecting or replacing brushes.
2. Replace both carbon brushes when either has less than !/4-in. length of carbon
remaining, or if the spring or wire is damaged or burned.
3. Using a slotted screwdriver, remove the black plastic cap on each side of the router
motor (Fig° 20) and carefully withdraw the spring-loaded brush assemblies° Keep
brushes clean and sliding freely in their guide channels.
t
OTE:To
reinstall
the same brushes,
make sure the brushes
go back in the
same way they came out.This
will avoid a break-in
period.
4,
Insert new brush assemblies
into guide channels,
with the carbon
part going in first,
being certain to fit the two metal "ears" into their slots in the channel
(Fig. 20).
5
Remember
to replace
both end caps after inspecting
or servicing
brushes.
Tighten
the
caps snugly,
but do not over-tighten,
The router should
be allowed
to "RUN IN" (run at
no load without
a cutter
bit) for 5 minutes
before
use, to seat the new brushes
properly°
Fig. 20
Cap
Ears
I Z_ WARNING:
For your safety, ALWAYS turn off switch and unplug router
motor from the power source before performing any maintenance
or cleaning,
LUBRICATION
All of the bearings in this tool are lubricated with a sufficient amount of high-grade
lubricant for the life of the tool under normal operating conditions.
Therefore, no further
lubrication is required.