D I M E N S I O N S
23 3/4" (603mm)
E L E C T R I C A L R AT I N G S
Rated Wattage
Model
Battery
DC Voltage
GC15012
SLC
6
GC15022
SLC
6
GC15032
SLC
6
GC15042
SLC
12
GC15052
SLC
12
GC15122
SNC
6
GC15132
SNC
6
GC15142
SNC
6
GC15172
SNC
12
GC15182
SNC
12
SLC=Sealed Lead Calcium Battery
SNC=Sealed Nickel Cadmium Battery
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : G C 1 5 0 1 2 C L
Options
Model Number
(Add as suffix)
GC15012
A=Ammeter
GC15022
CL=Cylinder Heads
GC15032
DR=Halogen Pinchback Designer
GC15042
Heads
GC15052
SD=Self-Diagnostics (GC15012,
GC15122
GC15042, GC15052,
GC15132
GC15122, GC15132,
GC15142
GC15172, GC15182, Only)
GC15172
TDM=Time Delay Monitor
GC15182
V=Voltmeter
Alternate Lamps
Other Options
E n e r g y D a t a
Input Current (Max.):
Model No.
120V
GC15012, GC15022, GC15032 .12A
GC15042, GC15052
.30A
GC15122
.06A
GC15132
.07A
GC15142
.08A
GC15172
.13A
GC15182
.15A
(1)
Consult your Cooper Lighting Representative.
COOPER LIGHTING - SURE-LITES
6 5/8"
(168mm)
5 3/4"
(146mm)
6 5/8"
(168mm)
5 1/8"
(130mm)
to 87 1/2% of rated D.C. Voltage
1 1/2 hours
2 hours
3 hours
4 hours Type
27
24
18
54
48
36
85
66
50
36
30
20
54
48
36
15
12
8
24
18
12
48
36
24
30
24
16
48
36
24
Accessories
(Order separately)
VK1 =Voltmeter
WG12 =Wire Guard
WG17 =Wire Guard for use
with CL heads
(1)
(1)
277V
.05A
.13A
.03A
.04A
.05A
.06A
.07A
D E S C R I P T I O N
The GC Series combines a
clean, sleek, contemporary
appearance with state-of-the-art
electronics. Specifically
designed for initial and retrofit
installations where a recessed
unit is desired to maximize
aesthetics. The unit is ideal for
locations with limited wall
space and where panoramic
positioning is necessary for the
ceiling mounted lampholders to
provide proper light
distribution. Ideal for stores,
offices, hospitals and school
corridors.
Lamp Information
Wattage
14
Incandescent
9
28
Incandescent
9
40
Incandescent
9
16
Incandescent
9
28
Incandescent
9
6
Incandescent
7.2
10
Incandescent
7.2
20
Incandescent
7.2
12
Incandescent
9
20
Incandescent
9
GC SERIES
R e c e s s e d H o u s i n g
S u s p e n d e d C e i l i n g
E M E R G E N C Y L I G H T
• Dual-voltage input
120/277VAC, 60Hz
Number
• 20 gauge die-formed steel
29-84
housing with white powder
29-84
coat finish
29-84
29-86
• Two high-impact, fully
29-86
adjustable thermoplastic
29-88
heads
29-88
29-88
• Knockout, conduit or cord
29-86
set
29-86
• Flanged for mounting in
grid-type suspended
ceilings
• Above ceiling access
required for maintenance
• Single modular electrical
connector
• Remote Capability
• Line-latching, Solid-State
voltage limited charger,
Solid-State switching, low-
voltage disconnect,
brownout circuit,
overload/short-circuit
protection, test
switch/power indicator
light
• UL 924 Listed, Life Safety
NFPA 101, NEC/OSHA,
most state and local codes
COOPER LIGHTING
®
607