SMCGS8P-Smart INSTALLATION GUIDE Installationsanleitung EZ Switch 10/100/1000 8-Port Web Smart Switch with PoE...
Page 3
EZ Switch 10/100/1000 Installation Guide From SMC’s EZ line of low-cost workgroup LAN solutions 20 Mason Irvine, CA 92618 Phone: (949) 679-8000 June 2007 Pub. # 150000022900H E062007-DT-R02...
Page 4
No license is granted by implication or otherwise under any patent or patent rights of SMC. SMC reserves the right to change specifications at any time without notice.
“Active” SMC product. A product is considered to be “Active” while it is listed on the current SMC price list. As new technologies emerge, older technologies become obsolete and SMC will, at its discretion, replace an older product in its product line with one that incorporates these newer technologies.
Page 6
WHICH MAY VARY FROM STATE TO STATE. NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR STATUTORY RIGHTS. * SMC will provide warranty service for one year following discontinuance from the active SMC price list. Under the limited lifetime warranty, internal and external power supplies, fans, and cables are covered by a standard one-year warranty from date of purchase.
Page 7
Compliances and Safety Warnings FCC - Class A This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
CE Mark Declaration of Conformance for EMI and Safety (EEC) This information technology equipment complies with the requirements of the Council Directive 89/336/EEC on the Approximation of the laws of the Member States relating to Electromagnetic Compatibility and 73/23/EEC for electrical equipment used within certain voltage limits and the Amendment Directive 93/68/EEC.
Faser-TX-Anschluß und auf die Faserkabelenden schauen, während diese eingeschaltet sind. Power Cord Safety Please read the following safety information carefully before installing this switch: Warning: Installation and removal of the unit must be carried out by qualified personnel only. • The unit must be connected to an earthed (grounded) outlet to comply with international safety standards.
Page 10
HO3VVF3GO.75 (minimum). IEC-320 receptacle. Veuillez lire à fond l'information de la sécurité suivante avant d'installer le Switch: AVERTISSEMENT: L’installation et la dépose de ce groupe doivent être confiés à un personnel qualifié. • Ne branchez pas votre appareil sur une prise secteur (alimentation électrique) lorsqu'il n'y a pas de connexion de mise à...
Page 11
France et Pérou uniquement: Ce groupe ne peut pas être alimenté par un dispositif à impédance à la terre. Si vos alimentations sont du type impédance à la terre, ce groupe doit être alimenté par une tension de 230 V (2 P+T) par le biais d’un transformateur d’isolement à rapport 1:1, avec un point secondaire de connexion portant l’appellation Neutre et avec raccordement direct à...
Warning: This switch uses lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation. However,...
All printed documentation for this product uses biodegradable paper that originates from sustained and managed forests. The inks used in the printing process are non-toxic. Purpose This guide details the hardware features of this switch, including Its physical and performance-related characteristics, and how to install the switch. Audience This guide is for system administrators with a working knowledge of network management.
Page 19
Tables Table 1-1 Port Status LEDs Table 1-2 Power Status LED Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length Table 4-2 Maximum 1000BASE-SX Fiber Optic Cable Length Table 4-3 Maximum 1000BASE-LX Fiber Optic Cable Length Table 4-4 Maximum 1000BASE-LH Fiber Optic Cable Length Table 4-5 Maximum Fast Ethernet Cable Length Table 4-6...
Page 20
Figure 2-4 Making VLAN Connections Figure 3-1 RJ-45 Connections Figure 3-2 Attaching the Brackets Figure 3-3 Installing the Switch in a Rack Figure 3-4 Attaching the Adhesive Feet Figure 3-5 Inserting an SFP Transceiver into a Slot Figure 3-6 Power Socket...
Chapter 1: Introduction Overview The SMCGS8P-Smart is an intelligent Layer 2 switch with 8 10/100/1000BASE-T ports, one of which is a Gigabit combination port transceiver slot. The switch’s 8 10/100/1000 Mbps ports support the IEEE 802.3af Power-over-Ethernet (PoE) standard that enables DC power to be supplied to attached devices over the data wire pairs in the connecting Ethernet cable.
Port 1 on the switch can provide up to 25 W of power to an attached device at the standard 48 DC voltage. Ports 2-8 can provide up to 15.4 W of power. However, all ports can only provide up to 7.5 W of power when connected to PoE devices...
Description of Hardware 10/100/1000BASE-T Ports The switch contains 8 RJ-45 ports that operate at 10 Mbps or 100 Mbps, half or full duplex, or at 1000 Mbps, full duplex. Because all ports on the switch support automatic MDI/MDI-X operation, you can use straight-through cables for all network connections to PCs or servers, or to other switches or hubs.
On Green Condition Power Green Power Supply Socket The power socket is located on the rear panel of the switch. The standard power socket is for the AC power cord. 100-240V ~50-60Hz 1.5A Table 1-1 Port Status LEDs Status network activity network activity No link.
When networks are based on repeater (hub) technology, the distance between end stations is limited by a maximum hop count. However, a switch turns the hop count back to zero. So subdividing the network into smaller and more manageable segments, and linking them to the larger network by means of a switch, removes this limitation.
Network Planning Application Examples The switch is not only designed to segment your network, but also to provide a wide range of options in setting up network connections. Some typical applications are described below. Supplying PoE The switch is an excellent choice for supplying power to connected PoE devices such as web cameras, IP telephones or access points.
With 8 1000Mbps parallel bridging ports (i.e., 8 distinct collision domains), this switch can function as an efficient bridged node that is ideal for a meeting room environment. Low noise cooling fans make the switch inobtrusive for such a setting.
VLANs assigned to the inter-switch links. R&D VLAN 1 Tagged Ports Finance VLAN 2 Testing VLAN 3 VLAN 4 Note: When connecting to a switch that does not support IEEE 802.1Q VLAN tags, use untagged ports. Power LINK/ACT Untagged Ports VLAN unaware switch Marketing Finance...
Application Notes Full-duplex operation only applies to point-to-point access (such as when a switch is attached to a workstation, server or another switch). When the switch is connected to a hub, both devices must operate in half-duplex mode. For network applications that require routing between dissimilar network types, you can attach the switch directly to a multi-protocol router.
Chapter 3: Installing the Switch Selecting a Site switch units can be mounted in a standard 19-inch equipment rack or on a flat surface. Be sure to follow the guidelines below when choosing a location. • The site should: • be at the center of all the devices you want to link and near a power outlet.
• A screwdriver (Phillips or flathead, depending on the type of screws used) Mounting A switch unit can be mounted in a standard 19-inch equipment rack or on a desktop or shelf. Mounting instructions for each type of site follow.
Rack Mounting Before rack mounting the switch, pay particular attention to the following factors: • Temperature: Since the temperature within a rack assembly may be higher than the ambient room temperature, check that the rack-environment temperature is within the specified operating temperature range (See page C-1.).
Mount the device in the rack, using four rack-mounting screws (not provided). Figure 3-3 Installing the Switch in a Rack If installing a single switch only, turn to “Connecting to a Power Source” at the end of this chapter. If installing multiple switches, mount them in the rack, one below the other, in any order.
Set the device on a flat surface near an AC power source, making sure there are at least two inches of space on all sides for proper air flow. If installing a single switch only, go to “Connecting to a Power Source” at the end of this chapter.
Installing the Switch Connecting to a Power Source To connect a device to a power source: Insert the power cable plug directly into the socket located at the back of the device. Plug the other end of the cable into a grounded, 3-pin, AC power source.
Figure 4-1 Making Twisted-Pair Connections If the device is a PC card and the switch is in the wiring closet, attach the other end of the cable segment to a modular wall outlet that is connected to the wiring closet.
It is actually part of the patch panel. Instructions for making connections in the wiring closet with this type of equipment follows. Attach one end of a patch cable to an available port on the switch, and the other end to the patch panel.
62.5/125 micron multimode fiber optic cabling with an LC connector at both ends. Warning: The switch use lasers to transmit signals over fiber optic cable. The lasers are compliant with the requirements of a Class 1 Laser Product and are inherently eye safe in normal operation.
Connect one end of the cable to the LC port on the switch and the other end to the LC port on the other device. Since LC connectors are keyed, the cable can be attached in only one orientation. Figure 4-3 Making Connections to SFP Transceivers As a connection is made, check the Link LED on the switch corresponding to the port to be sure that the connection is valid.
However, note that because switches break up the path for connected devices into separate collision domains, you should not include the switch or connected cabling in your calculations for cascade length involving other devices.
100 Mbps Fast Ethernet Collision Domain Table 4-5 Maximum Fast Ethernet Cable Length Type Cable Type 100BASE-TX Category 5 or better 100-ohm UTP or STP 10 Mbps Ethernet Collision Domain Table 4-6 Maximum Ethernet Cable Length Type Cable Type 10BASE-T Categories 3, 4, 5 or better 100-ohm UTP Connectivity Rules...
For each piece of equipment, identify the devices to which it is connected. • Note the length of each cable and the maximum cable length supported by the switch ports. • For ease of understanding, use a location-based key when assigning prefixes to your cable labeling.
• Be sure the cable is plugged into both the switch and corresponding device. • If the switch is installed in a rack, check the connections to the punch-down block and patch panel. • Verify that the proper cable type is used and its length does not exceed specified limits.
IP address. Also, be sure the port through which you are connecting to the switch has not been disabled. If it has not been disabled, then check the network cabling that runs between your remote location and the...
In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight through to pins 1, 2, 3, and 6 at the other end of the cable. When using any RJ-45 port on the switch, you can use either straight-through or crossover cable.
If the twisted-pair cable is to join two ports and only one of the ports has an internal crossover (MDI-X), the two pairs of wires must be straight-through. (When auto-negotiation is enabled for any RJ-45 port on the switch, you can use either straight-through or crossover cable to connect to any device type.) You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet connections.
RJ-45 port on the switch, you can use either straight-through or crossover cable to connect to any device type.) You must connect all four wire pairs as shown in the following diagram to support Gigabit Ethernet connections. EIA/TIA 568B RJ-45 Wiring Standard...
Cables 1000BASE-T MDI-X and MDI Port Pinouts MDI-X Signal Name Bi-directional Data One Minus (BI_D1-) Bi-directional Data Three Plus (BI_D3+) Bi-directional Data Three Minus (BI_D3-) Cable Testing for Existing Category 5 Cable Installed Category 5 cabling must pass tests for Attenuation, Near-End Crosstalk (NEXT), and Far-End Crosstalk (FEXT).
Internal, auto-ranging transformer: 100 to 240 VAC, 50 to 60 Hz Power Consumption 165 W maximum (full PoE load) Maximum Current 1.5 A @ 110 VAC 0.75 A @ 220 VAC Switch Features Forwarding Mode Store-and-forward Throughput Wire speed Management Features...
Standards IEEE 802.3-2005 Ethernet, Fast Ethernet, Gigabit Ethernet IEEE 802.3af Power-over-Ethernet IEEE 802.1D Spanning Tree Protocol IEEE D802.1Q Virtual LAN IEEE 802.1X, Port-Based Network Access Control, 2001 ISO/IEC 8802-3 Compliances CE Mark Emissions FCC Class A CISPR Class A Immunity EN 61000-4-2/3/4/5/6/8/11 Safety UL/CUL (UL60950-1, CSA 22.2 No.
Appendix D: German Instructions Eine Site Auswählen (Selecting a Site) Die Schalter können in ein Standard-19-Zoll-Ausrüstungsgestell oder auf eine flache Ebene montiert werden. Zum Auswählen eines Standortes beachten Sie bitte die nachstehenden Richtlinien. • Die Site sollte: • Sich in der Mitte aller anzuschließenden Geräte sowie in der Nähe einer Netzsteckdose befinden;...
Befestigen Sie das Gerät mit vier Rackmontageschrauben (nicht beigelegt) an dem Rack. Wenn Sie nur einen Switch installieren, dann springen Sie bitte über zu "Verbinden mit einer Stromquelle" auf Seite 3-6 am Ende dieses Kapitels. Wenn Sie mehrere Switches installieren möchten, dann montieren Sie sie...
Page 59
Glossary 10BASE-T IEEE 802.3 specification for 10 Mbps Ethernet over two pairs of Category 3 or better UTP cable. 100BASE-TX IEEE 802.3u specification for 100 Mbps Fast Ethernet over two pairs of Category 5 or better UTP cable. 1000BASE-LH Specification for long-haul Gigabit Ethernet over two strands of 9/125 micron core fiber cable.
Page 60
Glossary CSMA/CD CSMA/CD (Carrier Sense Multiple Access/Collision Detect) is the communication method employed by Ethernet, Fast Ethernet, or Gigabit Ethernet. End Station A workstation, server, or other device that does not forward traffic. Ethernet A network communication system developed and standardized by DEC, Intel, and Xerox, using baseband transmission, CSMA/CD access, logical bus topology, and coaxial cable.
Page 61
Glossary IEEE 802.3x Defines Ethernet frame start and stop requests and timers used for flow control on full-duplex links. (Now incorporated in IEEE 802.3-2005.) IEEE 802.3z Defines CSMA/CD access method and physical layer specifications for 1000BASE Gigabit Ethernet. (Now incorporated in IEEE 802.3-2005.) LAN Segment Separate LAN or collision domain.
Page 62
Glossary Redundant Power Supply (RPS) A backup power supply unit that automatically takes over in case the primary power supply should fail. RJ-45 Connector A connector for twisted-pair wiring. Switched Ports Ports that are on separate collision domains or LAN segments. Telecommunications Industry Association Transmission Control Protocol/Internet Protocol (TCP/IP) Protocol suite that includes TCP as the primary transport protocol, and IP as the...
Page 63
IEEE 802.3ae 10 Gigabit Ethernet 1-5 IEEE 802.3u Fast Ethernet 1-5 IEEE 802.3z Gigabit Ethernet 1-5 indicators, LED 1-3 installation connecting devices to the switch 4-2 desktop or shelf mounting 3-4 port connections 4-1 power requirements 3-1 problems A-2 rack mounting 3-3...
Page 64
Index management agent 1-2 features 1-5, C-2 SNMP 1-2 mounting the switch in a rack 3-3 on a desktop or shelf 3-4 network connections 4-1 examples 2-2 package contents 3-2 pin assignments B-1 1000BASE-T B-3 100BASE-TX/10BASE-T B-1 ports, connecting to 4-1...
Page 66
Technische ondersteuningsinformatie beschikbaar op www.smc.com PORTUGUES Informações sobre Suporte Técnico em www.smc.com SWEDISH Information om Teknisk Support finns tillgängligt på www.smc.com INTERNET E-mail address: techsupport@smc.com Driver updates http://www.smc.com/ index.cfm?action=tech_support_drivers_downloads World Wide Web http://www.smc.com/ 20 Mason • Irvine, CA 92618 • Phn: 949-679-8000 • www.smc.com...