DESCRIPTION
Fail-Safe's MPWA series combines a multi-function, wall mounted luminaire
with the architectural styling of today's healthcare environment. Through
innovative features, the MPWA accommodates multiple applications
throughout the healthcare environment while offering an appealing and
highly styled design for all architectural tastes. The MPWA luminaire has
been designed with the patient and healthcare professional in mind. The
MPWA is separated into two compartments: up light for general ambient
room lighting and down light for reading/direct task lighting to accommo-
date the needs of the patient or healthcare professional. UL Listed.
SPECIFICATION FEATURES
Application
The MPWA is designed for use in
healthcare environments,
specifically for use in patient
rooms over beds to facilitate all of
the tasks required by the patient
and medical staff. Its exceptional
aesthetics make it ideal for other
applications such as over vanities,
examination areas, rest rooms,
hallways and offices.
A ... Lens
Up light: .125" thick, prismatic K12
pattern, acrylic lens is standard
(prisms on the inside for ease of
cleaning). Down light: .125" thick,
contoured drape formed, prismatic
K12 pattern, acrylic lens is
standard (prisms inside).
B ... Fasteners
Nickel-plated thumbscrews are
standard (requires no tools to
remove lens assembly).
C ... Construction
Outer housing is 18 gauge,
die-formed, cold rolled steel with
seam-welded ends. Back pan
housing is 20 gauge, die formed
cold-rolled steel. Power tray and
reflector are 20 gauge cold rolled
steel.
LAMP CONFIGURATIONS
1 7/8"
[47MM]
1 7/8"
[47MM]
1 7/8"
[47MM]
Specifications and Dimensions subject to change without notice.
D ... Lamps
T8 Linear Fluorescent
T5 HO Linear Fluorescent
E ... Ballast Options
T8 Electronic Instant Start
T5 Electronic Programmed Start
T8 Magnetic-HPF
B
E
6"
[153mm]
MOUNTING DIMENSIONS
24 3/8" [620mm]
22" [559mm]
8" [203mm]
[153mm]
2 1/4"
3/16 X 11/16"
[57mm] Dia.
[4.8 X 17.5mm]
Access Hole
Keyhold Mtg. Holes
3/16 X 11/16"
[4.8 X 17.5mm]
Keyhold Mtg. Holes
Consult your representative for additional options and finishes.
Catalog #
Project
Comments
Prepared by
Finish
High gloss white polyester powder
coat finish is standard on exterior
housing. A multistage cleaning and
painting process is utilized. Interior
reflector is high reflectance white,
minimum reflectance 92%. Custom
colors are available.
Labels
UL/cUL Listed for Damp Locations
D
A
8 9/16"
[217mm]
36 3/8" [925mm]
34" [864mm]
20" [508mm]
6"
2 1/4"
3/16 X 11/16"
[57mm] Dia.
[4.8 X 17.5mm]
Keyhold Mtg. Holes
Access Hole
48 3/8" [1229mm]
46" [1168mm]
32" [813mm]
16" [406mm]
6"
[153mm]
2 1/4"
[57mm] Dia.
Access Hole
FAIL-SAFE
Type
Date
51W - 216W
ARCHITECTURAL
WALL MOUNTED
C
ENERGY DATA
Input Watts:
T5H0 Fluorescent Lamps
Electronic Ballasts*
(3) 24W T5 HO Lamps: 79W
(4) 24W T5 HO Lamps: 104W
(3) 39W T5 HO Lamps: 127W
(4) 39W T5 HO Lamps: 174W
(3) 54W T5 HO Lamps: 182W
(4) 54W T5 HO Lamps: 240W
*Energy Data calculated using
3 ballasts per each lamp
configuration. (Programmed start,
normal light output, average ballast
factor 0.95 to 1.1)
T8 Fluorescent Lamps
Electronic Ballasts*
(3) 17W T8 Lamps: 54W
6"
(4) 17W T8 Lamps: 68W
[153mm]
(3) 25W T8 Lamps: 74W
(4) 25W T8 Lamps: 94W
(3) 32W T8 Lamps: 90W
(4) 32W T8 Lamps: 116W
*Energy Data calculated using
3 ballasts per each lamp
configuration. (Instant start, normal
light output, average ballast factor
0.9 to 1.0)
ADC041674
04/04/2007 9:10:39 AM
®
MPWA
Fluorescent
HEALTHCARE
LUMINAIRE

Advertisement

loading

Summary of Contents for Cooper Lighting MPWA

  • Page 1 MPWA accommodates multiple applications throughout the healthcare environment while offering an appealing and highly styled design for all architectural tastes. The MPWA luminaire has been designed with the patient and healthcare professional in mind. The MPWA is separated into two compartments: up light for general ambient room lighting and down light for reading/direct task lighting to accommo- date the needs of the patient or healthcare professional.
  • Page 2 The lower lamp in the same compartment is intended for The MPWA is used for obtaining reading and other ordinary tasks. maximum efficiency while (The upper lamp in the lower providing cut off and glare control compartment is switched to the remaining of the room’s...
  • Page 3 ORDERING INFORMATION = LED Night Light (50,000 hrs.) provided by Cooper Specifications and Dimensions subject to change without notice. ADC041674 04/04/2007 9:10:39 AM Fail-Safe • Customer First Center • 1121 Highway 74 South • Peachtree City, GA 30269 • TEL 770.486.4800 • FAX 770.486.4801...
  • Page 4 (0-180)=1.38 (90-270)=1.16 Efficiency=64.1% C a n d l e p owe r D i s t r i b u t i o n Reading & Exam Light (2 Lamps, Lower Compartment) MPWA-2/254-120-EB53-EXLR-LVC P-GCO-NRLL Lamp=(2) Lumens=4400 each Spacing Criteria (0-180)=1.82 (90-270)=1.20 Efficiency=57.4%...

This manual is also suitable for:

Fail-safe mpwa