Page of 2
Download Bookmark Comment

Cooper Lighting Metalux VT3-132 Specification

Cooper lighting industrial lamp specification sheet.
Hide thumbs
   
COOPER LIGHTING - METALUX
®
DESCRIPTION
Type
The VT3 Series is a contemporary looking energy efficient industrial
Catalog #
Vaportite fixture that features rugged and durable construction. The VT3
incorporates a full metal clear tray inside a reinforced fiberglass housing
Project
with a high impact diffuser. This Vaportite series is suitable for interior and
exterior applications and can be surface or chain mounted.
Date
Comments
The VT3 Series has been designed for maximum operation in commercial
institutional and industrial environments where weathering, high
Prepared by
temperature, humidity and dust or corrosive fumes are present.
SPECIFICATION FEATURES
A ... Construction
B ... Electrical*
C ... Shielding
Fiberglass housing is reinforced
Unit has full metal gear tray
New contemporary styled lens
polyester and self-extinguishing
secured by internal fasteners and
clear acrylic w/impact resistant
(ASTM-D635-74) plastic of a
tethers providing maximum
additives and linear prisms.
permanent pearl gray color. Top of
protection and rigidity. Ballasts are
"DR" - Clear low brightness pattern
housing has five embossments (2'
CBM/ETL Class "P" certified
acrylic with 15% high impact
unit), nine embossments (4' unit)
suitable to 70°F. (Cold temperature
additive.
and thirteen embossments (8'
ballasts are available for less than
"DR-100" - Clear low brightness
unit), providing mounting flexibi-
0°F starting with EHT (T5HO only),
pattern acrylic with 100% high
lity on uneven surfaces. A watertite
EB/PLUS and ER/PLUS Ballasts).
impact additive. Example:
hub for 1/2" conduit entry is
Rotor lock lampholders. Electrical
VT3-232DR-100
provided at each end of housing
components and fixtures are
(standard) for continuous feed.
UL/CUL listed for Wet Locations.**
VT3
Polyurethane gasketing is formed
IP65 approved with optional IP67
in the housing providing a
rating (4' only) with 8 latches.
132
continuous seamless seal for the
diffuser. Six sturdy cam latches
232
clamp diffuser tightly for a positive
A
B
C
seal between housing, gasketing
332
and diffuser.
154T5
254T5
4-13/16"
[123mm]
4' INDUSTRIAL
1, 2 OR 3 LAMP
Vaportite Industrial
6-15/16"
[177mm]
MOUNTING DATA
LAMP CONFIGURATIONS
41-1/2" [1054mm]
X
X
Optional Back Hub
Locations
4-13/16"
4-13/16"
[123mm]
[123mm]
38-3/4" [984mm]
E N E R G Y D ATA
1/4" x 28" Stud
(2 Places)
Input Watts:
X=1-13/32"
X=1-13/32"
Y
6-15/16"
EB Ballast & STD Lamps
[36mm]
[36mm]
[177mm]
6-15/16"
6-5/8"
Y=2-1/2"
[177mm]
132 (30)
[168mm]
[64mm]
232 (61)
X
X=5-3/8"
Y
4-13/16"
154T5 (54)
X
[137mm]
[123mm]
254T5 (106)
Y=4-3/16"
49-13/16" [1265mm]
[107mm]
Luminaire Efficacy Rating
X=1-13/32"
Y
LER = FI-73
[36mm]
6-15/16"
Catalog Number: VT3-232DR
Y=2-1/2"
[177mm]
[64mm]
INSTALLATION DATA
Yearly Cost of 1000 lumens,
3000 hrs at .08 KWH = $3.29
Relative Light Output Factors
*Reference the lamp/ballast data in the
To accurately predict how luminaires will perform in cold temperatures,
Technical Section for specific lamp/ballast
Cooper Lighting individually tested each configuration in the different
requirements.
ambient environments. The relative light output factor should be
**Not Suitable for Wet Locations if EL4
applied as an additional light loss factor component.
Option is added. Consult Pre Sales
Technical Support.
VT3 Series
MOUNTING
OPTIONAL CHAIN HANGING SET
-15°F (-26°C) 0°F (-18°C)
20°F (-6°C)
33°F (0°C)
50°F (10°C)
LAMPS CONTAIN MERCURY. DISPOSE ACCORDING
BRACKETS
(VT2-CHAIN/SET-U)
TO LOCAL, STATE OR FEDERAL LAWS
Furnished
0.67
0.97
0.99
Includes 6 ft. of chain, 4 large
VT3-232
Two per
S-Hooks and 4 small S-Hooks
VT3-254
0.73
0.76
0.86
0.90
0.94
4' Unit
Order One (1) Kit for each 4' Fixture
VT3-332
0.96
0.98
0.98
Four per
Two (2) Kits Recommended For
8' Unit
8' Fixture
VT3-354
0.91
0.93
Safe and convenient means of
disconnecting power
Specifications and Dimensions subject to change without notice.
ADF071376
Consult your representative for additional options and finishes.
10/06/2008 11:40:01 AM

   Related Manuals for Cooper Lighting Metalux VT3-132

   Summary of Contents for Cooper Lighting Metalux VT3-132

  • Page 1

    Relative Light Output Factors To accurately predict how luminaires will perform in cold temperatures, Cooper Lighting individually tested each configuration in the different ambient environments. The relative light output factor should be applied as an additional light loss factor component.

  • Page 2

    Top Hub required when stem mounting. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Specifications and Dimensions subject to change without notice.

This manual also for:

Metalux vt3-154t5, Metalux vt3-232, Metalux vt3-254, Metalux vt3-254t5, Metalux vt3-332, Metalux vt3-354

Comments to this Manuals

Symbols: 0
Latest comments: