Cooper Lighting Metalux 2P5GAX SERIES Specification Sheet

Cooper Lighting Metalux 2P5GAX SERIES Specification Sheet

Cooper lighting indoor lighting specification sheet

Advertisement

Quick Links

COOPER LIGHTING - METALUX
2P5GAX SERIES
1 ' x 2 ' , 1 ' x 4 ' , 2 ' x 2 ' ,
2 ' x 4 ' , 2 0 " x 2 4 " o r
2 0 " x 4 8 " P a r a b o l i c
1 , 2 o r 3 L a m p
P a r a b o l i c L o u v e r
PA R A L U X V R E C E S S E D
A I R S U P P LY P R E C I S I O N
C U T- O F F T R O F F E R
• Equipped with energy
saving ballast/complies
with federal energy
efficiency standards
• Computer designed,
precision cell louver
technology
• Louver designed to
eliminate objectionable
glare in the VDT screen
• Low iridescent louver
minimizes iridescence
• Field convertible feature
• Floating louver/black reveal
• Efficient air handling options
DLS
Dimming Ballasts are
available
• End plate grid-lock
feature
(1)
• For information on flanged
fixture, including ceiling
opening size, see Technical
Section.
• UL/CUL Listed. Suitable for
damp locations.
388
COOPER LIGHTING
D E S C R I P T I O N
The Paralux V series features a
proprietary "Total Light Control
System" that has been designed
to eliminate glare reflections in
VDT screens by suppressing high
angle brightness. Meets today's
lighting standards. The luminaire
incorporates a precision cut-off
parabolic louver in a para-
contoured fixture housing. This
system complies with RP-1 and
meets today's lighting and
energy manage-ment standards.
The series is compatible with all
of today's popular ceiling
systems. The Paralux V, PC|2
series is the solution for
computer environ-ments and
open office areas.
O R D E R I N G I N F O R M AT I O N
S A M P L E N U M B E R : 2 P 5 G A X - 3 3 2 S 3 9 M I - 1 2 0 V - E B 8 1 - U
HM= Hard
Metric
HR=Heat
(1)
Removal
HRDO=Heat
Removal
Damper Open
HRDC=Heat
Removal
Damper Closed
Width
2'=2' width
Blank=1' width or
20" width
P=Paralux Louver
5=5" Louver Depth
Trim Type
G=Grid/Lay-in – Standard
G or T=Concealed T
(2)
G or T=Slot Grid
F=Flange Trim
MZ=Modular Trim
Convertible Fixture Standard G (Grid)
Type-Fixtures can be field converted to
(3)
T-option or vice-versa.
Fixture also
adaptable with flanged or modular trims.
AX=Air Supply Floating Louver
X=Blank Side/Floating Louver - Non-Air Supply (Omit A)
AVX=Air Supply Floating Louver with Directional Air Vane (Add V)
P R O D U C T I N F O R M AT I O N F O R PA R A L U X V
Housing
Lamp
Size
Quantity
1' x 2'
1 or 2
1' x 4'
1 or 2
2' x 2'
2
3
20" x 24"
2
20" x 48"
2
2' x 4'
2
3
*Example: 39= 3 rows of 9 (27 cells)
(1)
NOTES:
Integral end plate grid lock feature not available in heat removal.
housing only, appropriate shielding media assemblies must be utilized.
(5)
Not available when specifying emergencies, voltage must be specific.
For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting
Representative for availability and ordering information.
®
D I M E N S I O N S
NOMINAL SIZE
A
1' x 2'
11-3/4" (298mm)
1' x 4'
11-3/4" (298mm)
2' x 2'
23-3/4" (603mm)
2' x 2' (8 cell)
23-3/4" (603mm)
2' x 4'
23-3/4" (603mm)
2' x 4' (18 cell)
23-3/4" (603mm)
20" x 24"
19-3/4" (502mm)
20" x 48"
19-3/4" (502mm)
Number
of Lamps
1, 2 or 3 lamps
(Not included)
Wattage (Length)
17=17W T8 (24")
U15/8=31W T8 (24")
BX40=40W Biaxial (24")
32=32W T8 (48")
Louver Color
S=Silver
Cell Configuration*
(See below for Louver Options)
Louver Finish
MI=Specular/Mirrored (Low Iridescent)
VDT=VDT Soft Semi-Specular/Haze
(Low Iridescent)
WB=White & Black Longitudinal Louver
Blades (Specular/Mirrored Cross Blades)
1x4 only
WBVDT=White & Black Longitudinal
Louver Blades (VDT Soft Semi-
Specular/Haze Cross Blades) 1x4 only
Louver Cell
Number
Configuration*
of Cells
14
4
19
9
24
8
34
12
24
8
29
18
29
18
39
27
(2)
An EQ Grid Clip is recommended for all 9/16" ceiling systems.
(4)
Products also available in non-US voltages and frequencies for international markets.
B
7" (178mm)
7" (178mm)
6-1/8" (156mm)
6-3/4" (171mm)
6-1/8" (156mm)
6-5/8" (168mm)
6-1/8" (156mm)
7-3/8" (502mm)
WW
Options
Wall Wash
(See Options
Section)
(4)
Voltage
UNV=Universal
Packaging
(5)
Voltage 120-277
U=Unit Pack
347V=347 Volt
PAL=Job Pack,
out of carton
Options
PALC=Job Pack,
GL=Single Element Fuse
in carton
GM=Double Element Fuse
WTR=White Reveal
Lamps - for lamps installed, see
lamp options table
Flex - for flex installed, see flex
ordering table
Emergency - for EM installed,
see EM options table
(4)
Ballast Type
Blank=Standard Magnetic Ballast (Biax & 20W)
EB5 = T5 Biax Electronic Instant Start. Total
Harmonic Distortion < 20%
No. of Ballast
1, 2 or 3
LE3=T12 Magnetic Energy Saving
EB2 =T12 Electronic Rapid Start.
No. of Ballast
1 or 2
ER8 = T8 Electronic Program Rapid Start. Total
Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 = T8 Electronic Instant Start. Total Harmonic
Distortion < 10%
No. of Ballast
1, 2 or 3
EB8 /PLUS= T8 Electronic Instant Start. High
Ballast Factor >1.13. Total Harmonic
No. of
Distortion < 20%
Ballast
1, 2 or 3
TEB5 =T5 Biax Electronic Instant Start. Total
Harmonic Distortion < 10%
No. of Ballast
1, 2 or 3
DLS=Digital Lighting System Dimming
(For complete details on generic or to specify
manufacturer's ballast see pg. 469)
(3)
Convertibility applies to

Advertisement

loading

Summary of Contents for Cooper Lighting Metalux 2P5GAX SERIES

  • Page 1 Not available when specifying emergencies, voltage must be specific. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting COOPER LIGHTING Representative for availability and ordering information.
  • Page 2 0° to 55°, (1st level). Now notice the dark grey areas. This is where the light is restricted in the shielded zone, thus eliminating high angle brightness (glare) in the VDT screen. COOPER LIGHTING - METALUX RP-1 2ND LEVEL The 2nd level is relaxed. It is suitable for areas where intermittent computer work stations exist.

This manual is also suitable for:

Metalux 388