DESCRIPTION
The real workhorse in emergency lighting systems...these durable, reliable
units are unparalleled in performance and provide freedom from
maintenance. The HR Series units provide a low-cost, solid-state lighting
system for applications in industrial, commercial or multi-housing
environments. High and ultra-high capacity makes them ideal for
installations where a large number of heads/exits will be remotely operated.
SPECIFICATION FEATURES
Electronic
- Dual Voltage Input
120/277 VAC, 60 Hz
- Line-latching
- Solid-state Voltage
Limited Charger
- Solid-state Switching
- Low-Voltage Disconnect
- Brownout Circuit
- Overload/Short Circuit Protection
- Test Switch/Power
Indicator Light
- Isolation Transformer
Housing Construction
- 18-Gauge Die-Formed
Steel Housing
- 18-Gauge Die-Formed
Steel Cover
- Knockout, Conduit or Cord Set
- Universal J-Box Mounting
Pattern (High Capacity
Series Only)
4 1/4"
12 1/2"
[108mm]
[318mm]
5 3/4"
14 1/2"
[146mm]
[368mm]
Figure 1 High Capacity
ORDERING INFORMATION
S A M P L E N U M B E R : H R 8 7 C T D M
HR
Options (add as suffix)
Model Number
Alternate Lamps: Consult Cooper Lighting
HR87C
HR117C
A=Ammeter
HR12117C
V=Voltmeter
HR180C
TDM=Time Delay Monitor
HR12170C
Other Options: Consult Cooper Lighting
HR12210C
HR12360C
Specifications and Dimensions subject to change without notice.
COOPER LIGHTING - SURE-LITES
Housing Construction Cont.
- Keyhole Mounting Slots
- White Finish
Battery
- Sealed Lead Calcium,
Recombination
- Maintenance-Free, Long-Life
- Full Recharge Time,
24 hrs. (max.)
- Polarized Battery Terminals
Code Compliance
- UL 924 Listed
- City of Chicago Approval
No. 3238
- Life Safety NFPA 101
- CSA Certified (HR12117 Only)
- NEC/OSHA
- Most State and Local Codes
8 1/4"
[210mm]
9"
[229mm]
Figure 2 Ultra High Capacity
Accessories (order separately)
VK1=Voltmeter
Representative
3BRWH=Mounting Brackets (3-White Finish)
2MSWH=Mounting Shelf (High Capacity Units)
3MSWH=Mounting Shelf (Ultra-High Units)
CSK120=Cord Set (120 VAC)
CSK277 =Cord Set (277 VAC)
Representative
VS2=Polycarbonate Vandal Shield
WG7=Wire Guard (High Capacity units)
WG3=Wire Guard (Ultra High Capacity units)
Consult your representative for additional options and finishes.
Catalog #
Project
Comments
Prepared by
Warranty
- Unit: 1-year
- Battery: 5-year pro-rata
Head/Lamp Data
- Two Heads Standard
- Top Mounted
- Glare-Free Lens
- Fully Adjustable
- Remote Capability
- Metal Heads with Die Cast
Metal Swivel
- Halogen Lamp Standard
- Matches Housing Finish
18"
[457mm]
11 3/4"
[299mm]
17 1/4"
[438mm]
19 1/4"
[489mm]
®
Type
Date
HR87C
HR117C
HR12117C
H I G H C A PA C I T Y
S E A L E D L E A D C A L C I U M
B AT T E R Y
HR180C
HR12170C
HR12210C
HR12360C
U LT R A H I G H C A PA C I T Y
S E A L E D L E A D C A L C I U M
B AT T E R Y
Chicago Code
Emergency Lighting
E N E R G Y D AT A
HR87C
HR12170C
Input Current (Max.):
Input Current (Max.):
120V= .50A
120V= 1.08A
277V= .21A
277V= .45A
HR117C
HR12210C
Input Current (Max.):
Input Current (Max.):
120V= .53A
120V= 1.02A
277V= .22A
277V= .47A
HR12117C
HR12360C
Input Current (Max.):
Input Current (Max.):
120V= .26A
120V= 1.17A
277V= .13A
277V= .54A
HR180C
Input Current (Max.):
120V= .98A
277V= .43A
ADX041293