These units are designed to operate on 120 volts, 60 hertz, single phase. Arrange to have a
separate circuit wired from your power panel to an outlet near where the charger is to be located.
Locate the charger in a dry well ventilated place, either on a bench or wall.
Ratings
These 6 amp slow chargers are rated to series charge batteries as follows:
Model 41260 (T)
27 charge positions
Model 81260 (T)
72 charge positions
6 and 12 volt batteries may be intermixed in the series charging string up to the rating of the
charger. This charger is a SERIES charger. Batteries up to the D.C. voltage capacity of the
machine must be connected from negative of one battery to positive of next battery. This having
been done, the positive red clamp of charger is connected to positive end of battery string and
negative black clamp to negative end of battery string. Clip on type jumpers are supplied to make
the series connections easy. NOTE: Always make sure connections are clean and tight.
Charging Procedure
DANGER! Lethal voltages can be present at the battery clamps. Only
trained and qualified personnel should use this piece of equipment.
1. With batteries connected, set main switch or timer to ON position.
2. Next, adjust L.M.H. Switch ( Model 41260 (T) ) or fine control switch obtained, then
adjust the raise coarse control by advancing to the right until charge starts. Further adjust
with the L.M.H. or Fine Control if required. (DO NOT EXCEED 6 AMPS).
HAVING COMPLETED CHARGE OR REMOVING BATTERIES the following is the correct
procedure:
1. Turn raise coarse control knob to low position – extreme left.
2. Turn L.M.H. Switch or fine control switch knob to OFF position.
Instruction Manual
Model 41260 (T) and Model 81260 (T)
Battery Charger
1 – 8
1 – 4
1 –16
1 – 8
1
205B K o nrad Cres.
Markham, Ontario
L3R 8T9
Phone 905-513-1550
Fax 905-513-1557
www.chargers.ca
6 volts batteries in series.
12 volts batteries in series.
6 volts batteries in series.
12 volts batteries in series.

Advertisement

loading

Summary of Contents for Vulcan-Hart 41260 (T)

  • Page 1 205B K o nrad Cres. Markham, Ontario L3R 8T9 Phone 905-513-1550 Fax 905-513-1557 www.chargers.ca Instruction Manual Model 41260 (T) and Model 81260 (T) Battery Charger Installation Instructions These units are designed to operate on 120 volts, 60 hertz, single phase. Arrange to have a separate circuit wired from your power panel to an outlet near where the charger is to be located.
  • Page 2 3. Set Main switch or Timer to OFF position. CAUTION: NEVER REMOVE BATTERIES WHILE RECTIFIER IS IN OPERATION. A.C. and D.C. Fuse Protection: Open door, replace with 15 amp fuse only. Model 41260 (T) and Model 81260 (T) Silicon Slow Battery Charger Model 41260 (T) Model 81260 (T) Rated Output...