INTRODUCTION
Thank you for purchasing the RMR-136HG Multi-Channel Indoor-
Outdoor Thermohygrometer with Cable Free
TM
THGR268, and ExactSet
calendar clock.
This basic configuration consists of the main unit that is the
temperature and calendar clock station, and the thermohygrometer
sensor remote unit. The main unit can support up to 3 remote
sensors. Additional remote sensors are available.
The main unit has a large easy-read LCD screen that displays the
indoor temperature, clock with calendar, and temperature and
humidity data transmitted by the remote sensor to the main unit.
The RMR-136HG also records the maximum and minimum
indoor temperatures, and the maximum and minimum
temperatures/humidity data transmitted from the remote sensor.
The clock is a radio-controlled ExactSet
calendar. The clock automatically synchronizes time and date with
radio signals received from the US Atomic Clock, one of the world's
most accurate timepieces. Other clock/calendar features include
three-language choice for day-of-the-week display, a four-step
crescendo alarm and easy-change display modes. (To learn more
about the US Atomic Clock visit the US Department of Commerce's
National Institute of Standards and Technology website at:
www.nist.gov.)
TM
Clock
TM
sensor, model
TM
clock and includes a
1
MAIN UNIT FEATURES
A
B
C
D
E
J
K
Model No. RMR136HG
L
Remote Therm-Hygro
RMR136HG
M
Tested To Comply
With FCC Standards
FOR HOME OR OFFICE USE
N
R
C A B L E
F R E E
P M
C
E
AM
M
D
E X A C T S E T
R A D I O
C O N T R O L L E D
CHANNEL
G
MEMORY
SET / MODE
DAILY
O
P
Q
S
I
H
F

Advertisement

Table of Contents
loading

Summary of Contents for Oregon Scientific RMR-136HG

  • Page 1 E X A C T S E T R A D I O C O N T R O L L E D CHANNEL MEMORY SET / MODE DAILY Model No. RMR136HG Remote Therm-Hygro RMR136HG Tested To Comply With FCC Standards FOR HOME OR OFFICE USE...
  • Page 2 A. THREE-LINE LCD DISPLAY Easy-read LCD display of remote sensor and indoor temperature-humidity data and calendar clock functions B. [ ] BATTERY-LOW ICON Indicates that the remote sensor or main unit battery power is low and that batteries need replacement C.
  • Page 3: Remote Thermohygrometer Sensor

    REMOTE THERMOHYGROMETER SENSOR A. TWO-LINE LCD Displays the current temperature and humidity data measured by the remote sensor B. LED INDICATOR Flashes when the remote sensor transmits a reading to the main unit C/ F SLIDE SWITCH Select between degrees displayed in either Centigrade ( C) or Fahrenheit ( F) D.
  • Page 4 To install / replace batteries: 1. Gently lift the tab on the battery compartment door and slide to remove door. 2. Install the batteries strictly according to the polarities shown. Model No. RMR136HG Remote Therm-Hygro FOR HOME OR OFFICE USE 3. Press [RESET].
  • Page 5: Low Battery Warning

    LOW BATTERY WARNING The RMR-136HG features a low battery warning icon. This icon will appear on the second line of the LCD screen when the main unit batteries are low and need replacing. To determine low battery status of the remote sensor, press [CHANNEL] to sequence through the channels.
  • Page 6: How To Read The Kinetic Wave Display

    If remote sensor signals are not received by the main unit, blanks “ --- ” will be displayed on the LCD screen and the kinetic wave icon will not be displayed for that remote sensor. To trigger a remote sensor signal search: •...
  • Page 7: Remote Sensor Scanning

    Humidity Comfort-Level Comfortable TEMPERATURE AND HUMIDITY TREND INDICATOR ICONS The temperature-trend and humidity-trend indicator arrow icons show the trends based on collected readings. Arrow Indicator Temperature Rising Trend Arrow Indicator Humidity Rising Trend NOTE: If the temperature exceeds or fall below the temperature measuring range of the main unit or the remote sensor the main unit LCD screen display will show “HHH”...
  • Page 8: How To Use Channel-1 Temperature/Humidity Alarm

    HOW TO USE CHANNEL-1 TEMPERATURE/HUMIDITY ALARM Maximum and minimum temperature and humidity limits can be set for remote sensor channel-1 so that an alarm sounds when the user-selected limits are exceeded. The maximum and minimum temperatures and humidity are sequentially displayed by pressing [HIGH/LOW]. The High-Low displays are as follows: Sequence Respective Display...
  • Page 9: Calendar Clock Display Modes

    If the difficulty continues, reposition the remote sensor to a different location and/or closer to the main unit. CALENDAR CLOCK DISPLAY MODES The RMR136HG has two different time display modes:...
  • Page 10 MODE 1: Local Time Hour, Minute, Second, Month, Day MODE 2: Local Time Hour, Minute, Day-of-the-Week, Month, Day Press [SET/MODE] switch between the two time display modes. Note: When [24 hr OFF / ( )] is pressed the bottom line of the main unit LCD screen will display the alarm time.
  • Page 11: Selecting The Time Zone

    SELECTING THE TIME ZONE CAUTION: Do not press and hold [ZONE] for more than 3- seconds. Doing so will deactivate the automatic time signal reception capability. If the automatic signal reception is disabled, the signal strength icon will not be displayed. To reactivate the automatic signal reception, press [ ] for three seconds On the bottom line of the LCD screen there is a map outlining the...
  • Page 12: Manually Setting The Clock

    Please also visit our website at: www.oregonscientific.com WARRANTY Oregon Scientific warrants this product to be free of manufactur- ing defects for 90 days from date of retail purchase. Defective products should be returned to the place of retail purchase.
  • Page 13: Specifications

    1. Do not immerse the main unit or remote sensor in water. 2. Do not clean the product with abrasive or corrosive materials. They may scratch the plastic parts and corrode the electronic circuit. 3. Do not subject the product to excessive force, shock, dust, temperature or humidity which may result in malfunction, shorter electronic life span, damaged battery and distorted parts.
  • Page 14: Note On Compliance

    21(T) mm) the RMR-136HG. - Consult an experienced radio/television technican for assistance. Product Name Model Name Responsible Party : IDT (USA) Mr. David Childers 19861 SW : Remote Thermo-Hygro : RMR136HG 95 th Place Tualatin, Oregon 97062, U.S.A. Tel: 503-639-8883...
  • Page 15 CAUTION - The contents of this manual is subject to change without notice. - Due to printing limitations, the displays shown in this manual may differ from the actual product displays. - The manufacturer and its suppliers hold no responsibility to you or any other claim arising by using this product.