Issues Corrected Since 1.5.2 - Nortel Remote Gateway 9110 Release Note

Remote gateway 9100 series and rlc 1.6.0
Hide thumbs Also See for Remote Gateway 9110:
Table of Contents

Advertisement

June 2005

Issues Corrected Since 1.5.2

The following issues have been corrected since product release 1.5.2:
M3902 digital telephone sets connected to Remote Gateway 9150
units audio level (Q00969221)
When making a telephone call using an M3902 digital telephone set, speech
became faint. An unexpected Handsfree On message was being sent to an
M3902 digital telephone set whose Handsfree Allowed (HFA) Class of Service
was not programmed on the host PBX. In this case, the audio level of the M3902
digital telephone set would be drastically lowered and remain in the state until
the M3902 digital telephone set was re-set. Pressing the hookswitch quickly
several times in a row would induce this problem. The Remote Gateway 9150
unit now blocks the transmission of handsfree microphone related messages for
digital telephone sets with handsfree disabled.
ACD agents not receiving the call force tone (Q01021293)
Agents were receiving the ACD force tone, but not until after the call was
actually connected and the agent had already heard the far end answer. The
Remote Gateway 9150 unit's firmware now prevents the call force tone to the
ACD agent in a more expedited manner to prevent this from occurring.
1.6.0 Release Notes for Remote Gateway 9100 Series and RLC
17