Load Washer & Compression Load Cells
M1131/0509
INSTRUCTION
SHEET
Shop online at: omega.com e-mail: info@omega.com
For latest product manuals: omegamanual.info
Cautionary Notes for Safe Product Use.
DESCRIPTION
The OMEGA
®
LCWD Series Load Cell is a compact design with a full Wheatstone Bridge. Typical applications
include Clamping Forces, Die Loads, Bolt Stresses, Weighing Systems, and Structural Loads.
The load washer can be used as a washer, sensing compression force, or a compression load cell. When utilized
as a compression load cell, the load buttons supplied should be used. If the height of the buttons provided is too
restrictive, you can use one or none of the buttons. When you are using less than 2 buttons, be sure that the
active ridge (inside) of the washer is seated on a flat surface that transmits the load. Whenever possible, the
buttons provided should be used because they insure correct loading.
When used as a washer load cell, the set of spherical washers should be used as a washer cell, the set of
spherical washers should be used on one side of the load cell and a flat washer (not provided) on the other side of
the washer. When choosing a flat washer, make sure that the inner diameter of the flat washer is less than the
diameter of the inner ring of the load washer to insure that the active ridge is seated on the flat washer.
The following load cell types are available from OMEGA Engineering:
Dimensions in Inches (mm)
Part
Rated
Number
Capacity
LCWD-200
200 lb
LCWD-500
500 lb
LCWD-1K
1,000 lb
LCWD-2K
2,000 lb
LCWD-5K
5,000 lb
LCWD-10K
10,000 lb
LCWD-20K
20,000 lb
LCWD-50K
50,000 lb
LCWD-100K
100,000 lb
LCWD-200K
200.000 lb
UNPACKING
Remove the Packing list and verify that all equipment has been received. If there are any questions about the
shipment, please call OMEGA Customer Service Department.
Upon receipt of shipment, inspect the container and equipment for any signs of damage. Take particular note of
any evidence of rough handling in transit. Immediately report any damage to the shipping agent.
The carrier will not honor any claims unless all shipping material is saved for examination. After examining and removing
contents, save packing material and carton in the event reshipment is necessary.
WARNING! This symbol in this manual indicates a potential danger or hazard capable of
resulting in a serious injury or loss of life.
LOAD CELL
Weight
Bore
1.0 lb
0.40 (10)
1.0 lb
0.40 (10)
1.0 lb
0.40 (10)
1.0 lb
0.40 (10)
1.0 lb
0.40 (10)
1.0 lb
0.40 (10)
1.5 lb
0.50 (13)
2.0 lb
0.76 (19)
3.0 lb
1.01 (26)
6.0 lb
1.51 (39)
O. D.
H
Number
1.00 (25)
0.35 (9.0)
SPW-2
1.00 (25)
0.35 (9.0)
SPW-2
1.00 (25)
0.35 (9.0)
SPW-2
1.00 (25)
0.35 (9.0)
SPW-2
1.00 (25)
0.35 (9.0)
SPW-2
1.00 (25)
0.35 (9.0)
SPW-2
1.20 (30)
0.40 (10)
SPW-3
1.75 (44)
0.50 (13)
SPW-5
2.25 (57)
0.70 (18)
SPW-7
3.00 (77)
1.25 (32)
SPW-7
NOTE:
SPHERICAL WASHERS
Part
Bore
Size
Button
0.35 (8.9)
0.37 (9.4)
0.35 (8.9)
0.42 (10.7)
0.35 (8.9)
0.55 (14.0)
0.35 (8.9)
0.55 (14.0)
0.35 (8.9)
0.55 (14.0)
0.35 (8.9)
0.55 (14.0)
0.41 (10.3)
0.76 (19.3)
0.66 (16.7)
1.0 (25.4)
0.94 (23.8)
1.5 (38.0)
0.94 (23.8)
2.0 (50.8)
H of
Bolt
Size
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
5/16 (7.9)
3/8 (9.5)
5/8 (15.9)
7/8 (22.2)
7/8 (22.2)

Advertisement

loading

Summary of Contents for Omega LCWD Series

  • Page 1 The OMEGA ® LCWD Series Load Cell is a compact design with a full Wheatstone Bridge. Typical applications include Clamping Forces, Die Loads, Bolt Stresses, Weighing Systems, and Structural Loads. The load washer can be used as a washer, sensing compression force, or a compression load cell. When utilized as a compression load cell, the load buttons supplied should be used.
  • Page 2 DIMENSIONS TYPICAL EXAMPLE BLACK -EXC BOLT GREEN +OUT WHITE -OUT SPHERICAL WASHER LOAD CELL O.D. I.D. FLAT WASHER STRUCTURE CABLE INSTALLATION SCHEMATIC BOLT BUTTON SPHERICAL WASHER SET LOAD CELL RADIUS LOAD CELL BUTTON FLAT WASHER (NOT INCLUDED) STRUCTURE HOW LOAD CELLS WORK Load cells have an output or sensitivity in mV/V.
  • Page 3 SPECIFICATIONS Excitation: 10 Vdc (15 V Max) Output: 2 mV/V ± 20% Accuracy: Linearity, Hysteresis and Repeatability Combined: ≤ 10 K = ±0.5% BFSL > 10 K = ±0.75% BFSL Zero Balance: ±4.0% FSO Operating Temp Range: 40 to 127°C (-40 to 260°F) Compensated Temp Range: 16 to 71°C (60 to 160°F) Thermal Effects:...
  • Page 4 European New Approach Directives. OMEGA will add the CE mark to every appropriate device upon certification. The information contained in this document is believed to be correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.

This manual is also suitable for: