Models: M90AUL, M160AUL, M160AS, M290AUL, M430AUL, M290AS & M430AS
Beckett pumps are carefully inspected and tested to ensure both safety and operating performance for pond and fountain applications. However, failure to follow
the instructions and warnings in this manual may result in pump damage and/or serious injury. Be sure to read and save this manual for future reference.
M90AUL & M160AUL
-WARNING-
The National Electric Code requires that a ground fault circuit interrupter (GFCI) be used in the branch circuit supplying fountain pumps and other
pond equipment. See your electrical supplies dealer for this device.
Do not remove the grounding pin from the plug.
Do not connect to any voltage other than shown on the pump.
Do not pump flammable liquids.
Do not use with water above 87º Fahrenheit (30ºC).
To reduce the risk of electric shock, use only on portable self-contained fountains no larger than 5 feet in any dimension.
Risk of electrical shock. This pump is supplied with a grounding conductor and ground attachment plug. To reduce the risk of electric shock, be
certain that it is connected only to a properly grounded, grounding-type receptacle.
Ensure that the electrical cord loops below the electrical outlet to form a "Drip Loop".
This will prevent water from running down the cord into the electrical outlet.
-CAUTION-
Always disconnect from electrical outlet before handling the pump.
Do not let the pump run dry.
Do not lift the pump by the power cord.
Do not pump heated liquids.
Operate in freshwater only.
Operate pump completely submerged for proper cooling.
-ATTENTION-
In order to get best results, operate pump completely submerged.
Keep the water level above the minimum water level at ALL TIMES.
Sensor
Flow Control
Discharge
Impeller
Pump turns off when
water is below this sensor
M160AS
-MAINTENANCE-
M160AS For best results, take out the back cover, wipe the Sensor clean periodically (3-6 months).
M290AS &M430AS: For best results, take out the Sensor Screen, wipe the Sensor eye clean periodically (3-6 months).
Pump must be submerged in water below sensor to operate.
A clogged or dirty intake screen will greatly reduce performance. If the pump is used on a dirty surface, raise it slightly to reduce the amount of debris contacting the
intake.
If less flow is desired, adjust it with the flow control. Never restrict the pump's intake.
To clean the pump, remove the front plate and the impeller. Use a small brush or stream of water to remove any debris.
CAUTION: The pump shaft cannot be removed except M160AS.
IF THE PUMP FAILS TO OPERATE, CHECK THE FOLLOWING:
Check the circuit breaker and try another outlet to ensure the pump is getting electrical power.
NOTE: always disconnect from electrical outlet before handling the pump.
Check the pump discharge and tubing for kinks and obstructions. Algae build up can be flushed out with a garden hose.
Check the intake screen to ensure it is not clogged with debris.
Remove the pump inlet to access the impeller area. Turn the impeller to ensure it is not broken or jammed.
If the impeller area is encrusted with minerals or corrosion, gently scrape the area clean.
If your pump has been idle for an extended period, it may be necessary to apply a drop of light oil to the shaft and spin the impeller by hand until it turns freely.
Monthly maintenance will add to your pump's life.
SUBMERSIBLE PUMP OWNERS MANUAL
M160AS
Intake
Screen
Intake Screen
M290AUL & M430AUL
M290AUL & M430AUL
Intake Screen
M90AUL & M160AUL
Discharge
Impeller
Flow Control
M290AS & M430AS
Flow Control
Discharge
Impeller
Sensor
Sensor Screen
Discharge
Impeller
Flow
Control
Pump turns off when
water is below this
sensor
Intake
M290AS & M430AS
Screen

Advertisement

loading

Summary of Contents for Beckett M90AUL

  • Page 1 Models: M90AUL, M160AUL, M160AS, M290AUL, M430AUL, M290AS & M430AS Beckett pumps are carefully inspected and tested to ensure both safety and operating performance for pond and fountain applications. However, failure to follow the instructions and warnings in this manual may result in pump damage and/or serious injury. Be sure to read and save this manual for future reference.
  • Page 2 Modelos: M90AUL, M160AUL, M160AS, M290AUL, M430AUL, M290AS y M430AS Las bombas Beckett son inspeccionadas y probadas con cuidado para garantizar tanto la seguridad como el buen redimiendo operacional para su aplicación en estanques y fuentes. Sin embargo, el no seguir las instrucciones y advertencias de este manual puede dar como resultado que la bomba sufra daños y/o que se produzcan lesiones graves.
  • Page 3 APPLICATION: The warranty covers only properly installed and maintained Beckett products and is limited to application at normal temperature 32º F to 86º F, (0º C to 30º C) pumping fluids with a specific gravity up to 1.1 and with a pH range of 5 to 9 (fresh water). Other liquid applications and extreme temperature uses must be approved in advance by Beckett. The warranty does not apply to or cover damages or defects caused by external causes, including, but not limited to, improper or faulty installation or unauthorized modification, lightning, electrical surges, abuse, misuse or abnormal use or misapplication, including use in a manner inconsistent with the product’s intended function.

This manual is also suitable for:

M160aulM160asM290aulM430aulM290asM430as