Download Print this page
A.O. Smith ADMP - 115 Technical Specifications
A.O. Smith ADMP - 115 Technical Specifications

A.O. Smith ADMP - 115 Technical Specifications

Atmospheric commercial water heater

Advertisement

Quick Links

ADMP / ADM / ADMR
Atmospheric commercial
water heater
ADMP / ADM / ADMR - 40/50/60/80/90/115/135
An extensive range of atmospheric water heaters to suit most
larger hot water systems • Efficient, automatic hot surface igniter
• Removable control column for convenient servicing • Frost-
protection thermostat • Stainless steel burner for natural or LP gas
• Two access covers for comprehensive waterside tank maintenance
• External control connection • Voltage-free contact for general
fault indication • Optional ancillaries: Unvented kits • Destratification
pump kit • Powered anode • Flue fan kit • ADMP Permanent pilot
ignition • Pilot proving kit available • ADM Electronic ignition
• Control, high limit and energy cut-off thermostats provide triple
protection and ensure safe operation • ADMR Electronic ignition
• Flue damper to minimise standing losses • ThermoControl for
easy and flexible control / fault diagnosis • Programmable for
legionella purge cycle
Innovation has a name.

Advertisement

loading

Summary of Contents for A.O. Smith ADMP - 115

  • Page 1 ADMP / ADM / ADMR Atmospheric commercial water heater ADMP / ADM / ADMR - 40/50/60/80/90/115/135 An extensive range of atmospheric water heaters to suit most larger hot water systems • Efficient, automatic hot surface igniter • Removable control column for convenient servicing • Frost- protection thermostat •...
  • Page 2: Technical Specifications

    ADMP / ADM / ADMR Technical specifications Gas data natural gas 2H (G20) Input* Output Inlet pressure mbar Burner pressure mbar Gas consumption** Diameter main orifice Max. flue gas temperature °C Flue gas discharge kg/h Gas data butane 3+ (G30) Input* Output Inlet pressure...
  • Page 3 ADMP / ADM / ADMR Dimensions ADM / ADMR 1900 2100 1900 2100 2000 2085 1760 1960 1760 1960 1795 1870 1100 1100 1100 1100 1105 1105 1840 2040 1840 2040 1935 2010 M 565 1605 1810 1605 1810 1640 1715 1550 1760...
  • Page 4 Return circulation Gas supply Overfl ow pipe Expansion vent pipe A.O. Smith unvented system kits utilise combination valves. An ADM/ADMP or ADMR water heater should be installed in accordance with local standards and ventilation require- ments (category B11BS). Further installation and connection details can be found in...
  • Page 5: Terminal Strip Connections

    ADMP / ADM / ADMR Electrical diagram ADM TERMINAL STRIP CONNECTIONS Earth Neutral Phase input of controller Phase input of flue gas thermostat Phase output of flue gas thermostat COMPONENTS Two-terminal main switch Flue gas thermostat Indicator LED “Error” Indicator LED “Running” “RESET”...
  • Page 6 ADMP / ADM / ADMR Electrical diagram ADMR www.aosmithinternational.com TERMINAL STRIP CONNECTIONS Earth Neutral Phase input of controller Phase input of program- controlled pump Phase input of continuous pump Phase input of extra error signal Phase input of flue damper motor Phase output of flue damper motor (feedback)

This manual is also suitable for:

Admp 135Admp 40Admp 50Admp 60Admp 80Admp 90 ... Show all