Maxent MX-42XM11 Owner's Manual page 23

42” plasma monitor
Hide thumbs Also See for MX-42XM11:
Table of Contents

Advertisement

The following is an example of the communication process between the PC and the monitor using a program
such as HyperTerminal.
Example: Read Power Status followed by Power On command and input select to AV1 with disruption
Command and Data Tables
Description
Command
Read Data
REA
Volume
VOL
Power On/Off
PWR
Brightness
BRT
Contrast
CON
Color
CLR
Tint
TNT
Sharpness
SHP
Input Select
INP
V-Size
VSZ
V-Position
VPS
H-Size
HSZ
H-Position
HPS
Recall
RCL
Save
SAV
Mute
MUT
Language
LNG
Color Temp
TMP
Bass
BAS
Treble
TRB
Balance
BAL
Surround Sound
SRS
PC Status
Send command to read power status
Rcv acknowledgment of command received
Rcv OFF status from monitor
Rcv confirmation of command complete
Send command to POWER ON the monitor
Rcv acknowledgment of command
Rcv confirmation of command complete
Send command to switch to AV1 input
Rcv acknowledge of command not accepted
Send command to void previous command
Rcv acknowledgment of command received
Rcv confirmation of command complete
Send command to switch to AV1 input again
Rcv acknowledgment of command received
Rcv confirmation of command complete
Ready to send another command
Data Options
VOL, PWR, BRT, CON, CLR, TNT, SHP, INP, VSZ, VPS, HSZ, HPS, RCL, SAV, MUT, LNG,
TMP, BAS, TRB, BAL, BBE, SRS, TS1, TS2, CSR, CCD, ZOM, PIP, POP PIS,
POF, SIN, SWP, RGN, GGN, BGN, RBS, GBS, BBS, FPL, ILO, IUL, STS, BI1, BI2, BI3
001...100
PON=Power On, OFF=Power off
001...100
001...100
001...100
001...100
001...100
AV1=AV Input 1, AV2=AV Input 2, CP1=Component Input 1,
CP2=Component Input 2, RG1=RGB1, DV1=DVI1
001...100
001...100
001...100
001...100
000
000
MON=On, OFF=Off
ENG=English, SPA=Spanish, FFR=French
LOW=Low, MID=Middle, HIG=High, 65D=6500D
001...100
001...100
001...100
OFF=Off, STR=Stereo, MON=Mono
Display Connections
Monitor Status
Monitor rcv's command
Sends confirmation of command rcv'd to PC
Sends actual status of power to PC (OFF)
Sends confirmation of command completion
Monitor is not busy and waiting for command
Sends confirmation of command rcv'd to PC
Monitor powers on and sends confirmation
Monitor is busy doing another task
Sends busy status because it can't rcv data
Rcv's command to clear previous command
Sends confirmation of command rcv'd to PC
Clears command buffer and sends confirm
Monitor is not busy and rcv's command
Sends confirmation of command rcv'd to PC
Monitor switches to AV1 and sends confirm
Monitor is ready to accept another command
23

Advertisement

Table of Contents
loading

Table of Contents