Download Print this page
Leviton Decora Mural MDI06-1 Installation Instructions

Leviton Decora Mural MDI06-1 Installation Instructions

Single pole (one location) or 3-way (multi-location) 120vac, 60hz

Advertisement

Quick Links

C O L L E C T I O N B Y L E V I T O N
• Leviton's Decora
• Soft fade ON/OFF
• Minimum Brightness Adjustment
• Brightness Level Display
Single Pole (One location) or
3-Way (Multi-location)
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device must not cause harmful interference, and (2) This
device must accept any interference received, including interference that may cause undesired operation.
120VAC, 60Hz
Incandescent
WARNING:
Cat. No. MDIØ6-1, 600W
(w/brightness level display)
WARNING:
Cat. No. MDI1Ø-1, 1000W
WARNING:
(w/brightness level display)
FLUORESCENT LIGHTING, OR A MOTOR - OR TRANSFORMER - OPERATED APPLIANCE OTHER THAN APPROPRIATE LOW-VOLTAGE LIGHTING.
Magnetic Low-Voltage
CAUTION (For Incandescent Only):
Cat. No. MDMØ6-1, 600VA
CAUTION (For Magnetic Low-Voltage Only):
(w/brightness level display)
1. USE WITH MAGNETIC LOW-VOLTAGE TRANSFORMERS, INCANDESCENT, OR 120V HALOGEN FIXTURES ONLY. USE A LEVITON ELECTRONIC LOW-VOLTAGE
Cat. No. MDM1Ø-1, 1000VA
(w/brightness level display)
2. WHEN A MAGNETIC LOW-VOLTAGE CIRCUIT IS OPERATED AT A DIM LEVEL,
Total minimum wattage must
exceed 40W and 40VA
For use w/ Cat. No. MSØØR-1 Multi-Remote™
INSTALLATION INSTRUCTIONS
OTHER CAUTIONS:
1. USE ONLY ONE (1) DIMMER PER LOAD. FOR REMOTE OPERATION, USE THE
LEVITON MULTI-REMOTE
2. DISCONNECT POWER WHEN SERVICING OR CHANGING BULBS.
PK-93079-10-00-0A
3. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY
MULTI-GANG INSTALLATION:
LIMITED 2 YEAR WARRANTY AND EXCLUSIONS
When ganging dimmers, the side sections of the mounting strap must be removed. Use pliers to carefully bend
Leviton warrants to the original consumer purchaser and
side sections back and forth until they break off (refer to Figure 1). The side sections dissipate heat, so removing
not for the benefit of anyone else that this product at the
time of its sale by Leviton is free of defects in materials and
them requires a derating of the dimmer's capacity (refer to chart).
workmanship under normal and proper use for two years
MAXIMUM BULB WATTAGE (For Magnetic Low-Voltage Only):
from the purchase date. Leviton's only obligation is to correct
such defects by repair or replacement, at its option, if within
Low-voltage dimmers are rated in Volt-Amps (VA). The maximum bulb wattage is determined by the efficiency of
such two year period the product is returned prepaid, with
the transformer in the low-voltage lighting system. Transformer efficiencies will vary from different manufacturers;
proof of purchase date, and a description of the problem to
Leviton Manufacturing Co., Inc., Att: Quality Assurance
consider 75% efficient as average. Use the chart to determine maximum bulb wattage for typical transformer
Department, 59-25 Little Neck Parkway, Little Neck, New
efficiency ratings.
York 11362-2591. This warranty excludes and there is
TO INSTALL:
disclaimed liability for labor for removal of this product or
reinstallation. This warranty is void if this product is installed
1.
improperly or in an improper environment, overloaded,
misused, opened, abused, or altered in any manner, or is
not used under normal operating conditions or not in
2. Remove existing wallplate and switch or dimmer, if applicable.
accordance with any labels or instructions. There are no
other or implied warranties of any kind, including
3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are straight.
merchantability and fitness for a particular purpose, but if
4. Connect lead wires per appropriate WIRING DIAGRAM as follows:
any implied warranty is required by the applicable
jurisdiction, the duration of any such implied warranty,
including merchantability and fitness for a particular purpose,
is limited to two years. Leviton is not liable for incidental,
indirect, special, or consequential damages, including
without limitation, damage to, or loss of use of, any
equipment, lost sales or profits or delay or failure to perform
this warranty obligation. The remedies provided herein are
the exclusive remedies under this warranty, whether based
on contract, tort or otherwise.
5. Carefully position all wires to provide room in outlet box for dimmer. Mount dimmer into box with mounting
For Technical Assistance Call:
1-800-824-3005 (U.S.A. Only)
6. Restore power at circuit breaker or fuse. Turn the dimmer ON by pressing the upper half of the rocker. The
www.leviton.com
NOTE: This model incorporates a trim adjustment which will allow the installer to precisely set the low end of the
dimming range to suit each installation. This adjustment is preset at the factory and should require no further
adjustments for most installations. If adjustment is required proceed as follows, otherwise continue with step 9:
PK-93079-10-00-0A
PK-93079-10-00-0A
1
®
Style design
• Double Tap functions
• Power interruption – load returns to existing state
• ON/OFF LED indicates status of load
• Color conversion available
FCC COMPLIANCE STATEMENT
INSTALLATION INSTRUCTIONS
TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS.
IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.
TO AVOID OVERHEATING AND POSSIBLE DAMAGE TO THIS DEVICE AND OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE,
USE WITH INCANDESCENT OR 120V HALOGEN FIXTURES ONLY.
DIMMER TO CONTROL ELECTRONIC (SOLID STATE) LOW-VOLTAGE TRANSFORMERS.
WITH ALL LAMPS INOPERATIVE, EXCESS CURRENT MAY FLOW THROUGH THE
TRANSFORMER. TO AVOID POSSIBLE TRANSFORMER FAILURE DUE TO
OVERCURRENT, USE A TRANSFORMER THAT INCORPORATES THERMAL
PROTECTION OR A FUSE AT THE PRIMARY WINDINGS.
TM
, CAT. NO. MSØØR-1. DO NOT USE A 3-WAY SWITCH.
DEVICES MARKED CO/ALR OR CU/AL.
WARNING:
TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE
AND TEST THAT POWER IS OFF BEFORE WIRING!
LOW-VOLTAGE DIMMER ONLY TO THE PRIMARY (HIGH-VOLTAGE) SIDE OF A MAGNETIC LOW-
VOLTAGE TRANSFORMER. Twist strands of each lead tightly and, with circuit conductors, push firmly into
appropriate wire connector (see chart for allowable wire connector and number of conductor
combinations). Screw connectors on clockwise making sure that no bare conductor shows below the wire
connectors. Secure each connector with electrical tape.
NOTE: For single pole applications, cap YELLOW lead with an appropriate size wire connector. Secure
connector with electrical tape.
screws supplied.
GREEN LED will turn OFF to indicate power to the dimmer (when the dimmer is OFF, the LED is ON).
FEATURES
WIRE CONNECTOR / # OF CONDUCTOR COMBINATION CHART
1- #12 w/ 1 to 3 #14, #16 or #18
2- #14 w/ 1 #16 w/ 1 or 2 #18 or #20
2- #12 w/ 1 #14 w/ 1 #16 or #18
3- #14 w/ 1 or 2 #18 or #20
2- #12 w/ 1 #16 w/ 1 or 2 #18
4- #14 w/ 1 #16 or #18
2- #14 w/ 1 to 3 #16, #18 or #20
2- #16 w/ 1 #18 w/ 1 or 2 #20 or #22
4- #16 w/ 1 or 2 #18, #20 or #22
1- #14 w/ 1 #18 w/ 1 to 3 #20
1- #14 w/ 1 to 4 #16, #18 or #20
3- #14 w/ 1 #16 w/ 1 #18, #20, #22
2- #14 w/ 1 to 3 #16, #18 or #20
3- #14 w/ 1 #18 w/ 1 #20 or #22
MAXIMUM LOAD PER DIMMER FOR MULTI-GANG
Cat. No.
MDIØ6-1
MDI1Ø-1
MDMØ6-1
MDM1Ø-1
MAXIMUM BULB WATTAGE AT 75% EFFICIENCY
Rating
600VA
1000VA
Figure 1 – Dimmer Functions
WARNING:
CONNECT A MAGNETIC
Mounting Strap
Side Sections
Upper
Rocker
Brightness Level
Display
Lower
Rocker
Air Gap
Switch
10/16/02, 4:45 PM
Two
More than
Single
Gang
2 Gang
600W
500W
400W
1000W
800W
700W
600VA
500VA
400VA
1000VA
800VA
700VA
Two
More than
Single
Gang
2 Gang
450W
375W
300W
750W
600W
525W
Minimum Brightness
Adjustment Switch
ON/OFF
LED

Advertisement

loading

Summary of Contents for Leviton Decora Mural MDI06-1

  • Page 1 Cat. No. MDMØ6-1, 600VA CAUTION (For Magnetic Low-Voltage Only): (w/brightness level display) 1. USE WITH MAGNETIC LOW-VOLTAGE TRANSFORMERS, INCANDESCENT, OR 120V HALOGEN FIXTURES ONLY. USE A LEVITON ELECTRONIC LOW-VOLTAGE DIMMER TO CONTROL ELECTRONIC (SOLID STATE) LOW-VOLTAGE TRANSFORMERS. Cat. No. MDM1Ø-1, 1000VA (w/brightness level display) 2.
  • Page 2 COLOR CONVERSION PROCEDURE The color of this device can be changed to suit your interior design requirements. Simply obtain a color conversion kit of the appropriate color from your Leviton distributor and proceed as follows (please note that wallplate must be removed).

This manual is also suitable for:

Decora mural mdi10-1Decora mural mdm06-1Decora mural mdm10-1