Download Print this page

Chromalox PE429-1 Installation, Operation And Renewal Parts Identification

Circulation heaters for regular and fuel oil heating

Advertisement

Quick Links

RENEWAL PARTS IDENTIFICATION
2 x
Slot
A
The high capacity NWHO-45, 72 or 108 series are intended for
indoor use and are used primarily for oil heating.
The 45, 72 or 108 steel sheathed tubular elements are centered
in a 14", 16" or 18" diameter steel heating chamber, respectively,
and welded to a removable steel flange. The assembly is sur-
rounded by 2" of insulation and a sheet metal jacket.
Depending upon the order specifications, the NWHO-45, 72 or
108 may or may not be factory equipped with an MF2 or other
Chromalox thermostat. Such thermostats function to control outlet
1. Vertical mounting (axis of chamber
vertical) is preferred. Check factory
for constructions suitable for hori-
zontal mounting.
2. Mount heater with terminal enclo-
sure at top, and use lower nozzle as
inlet to the circulating fluid.
3. The NWHO-45, 72 and 108 series
of circulation heaters are provided
with mounting lugs to support the
heater chamber. Refer to Figure A
for one suggested mode of support.
4. Mount heaters to permit unre-
strained expansion of chamber due
to temperature. The large flange lug
© 2010 Chromalox, Inc.
Installation, Operation
and
E
3
/
"
1"
4
B
13
8
/
D
5 Conduit
Outlets
72° Apart
or
6" Outlet
6 Conduit
Outlets
60° Apart
Temperature
Control
6" Inlet
Type NWHO-45, 72, 108
Circulation Heaters for
Regular and Fuel Oil
Specifications – Table A
"
16
Model
NWHO-4590
NWHO-45125
NWHO-45150
NWHO-45175
NWHO-45200
C
NWHO-77220
Mounting
NWHO-77225
Lug Centers
NWHO-77250
NWHO-108300 240 or 480
NWHO-108325 240 or 480
NWHO-108350 240 or 480
These Dimensions are typical. Check factory for dimensions of a particular unit.
GENERAL
temperatures and to limit internal temperatures under abnormal
flow conditions. These controls do not fail-safe.
CAUTION: Users should install adequate back-up
controls and safety devices with their electric
heating equipment. Where the consequences of
failure may be severe, back-up controls are essen-
tial. Although the safety of the installation is the
responsibility of the user, Chromalox will be glad to
make equipment recommendations.
INSTALLATION
should be bolted solidly; however, the remaining lug should be
bolted loosely to allow freedom of movement with expansion.
5. DANGER: Hazard of Fire. Provide minimum of 6" spac-
ing from chamber and related piping to nearest combustible
material. Avoid operation of heater near combustible fluids or
in combustible vapor or gas laden atmosphere. Note: Contact
factory for heaters suitable for use in hazardous locations.
6. Provide adequate space at terminal end to permit withdrawal of
the heater from chamber should servicing be required.
7. If two or more heaters are needed to provide the needed heat-
ing capacity, arrange them for series flow.
8. DANGER: Possible Explosion. A pressure relief valve
should be provided by customer at outlet of vessel. There
should be no valving between vessel and relief valve.
Figure A
4
(Supersedes PE429)
FEBRUARY, 1986
Heating
No. 3Ø
Volts 3Ø
kW
Circuits
A
1
240 or 480
90
5
72
/
2
240 or 480
125
5
87
1
/
2
1
240 or 480
150
5
102
/
2
1
240 or 480
175
5
117
/
2
240 or 480
200
5
125
1
240 or 480
200
6
97
/
2
240 or 480
225
6
105
1
/
2
240 or 480
250
6
113
1
/
2
1
300
6
98
/
2
325
6
104
1
/
2
1
350
6
110
/
2
NWHO
PE429-1
161-058065-001
Dimensions (In.)
B
C
D
E
1
5
13
1
25
/
63
/
18
/
12
/
2
8
16
2
25
1
/
78
5
/
18
13
/
12
1
/
2
8
16
2
1
5
13
1
25
/
93
/
18
/
12
/
2
8
16
2
1
5
13
1
25
/
108
/
18
/
12
/
2
8
16
2
25
1
/
116
1
/
18
13
/
12
1
/
2
8
16
2
3
5
3
27
/
88
/
19
13
/
4
8
4
27
3
/
96
5
/
19
13
3
/
4
8
4
27
3
/
104
5
/
19
13
3
/
4
8
4
1
5
3
1
29
/
89
/
19
/
14
/
2
16
8
2
29
1
/
95
5
/
19
3
/
14
1
/
2
16
8
2
1
1
3
1
29
/
101
/
19
/
14
/
2
16
8
2

Advertisement

loading

Summary of Contents for Chromalox PE429-1

  • Page 1 Where the consequences of failure may be severe, back-up controls are essen- tial. Although the safety of the installation is the responsibility of the user, Chromalox will be glad to make equipment recommendations. INSTALLATION should be bolted solidly; however, the remaining lug should be bolted loosely to allow freedom of movement with expansion.
  • Page 2 RENEWAL PARTS IDENTIFICATION Order Renewal Parts on a Special Order Basis. Give the name of the part, part number, voltage, wattage and any special features Please refer to the Chromalox limited warranty applicable to this product at http://www.chromalox.com/customer-service/policies/termsofsale.aspx. WIRING Figure B...

This manual is also suitable for:

Nwho-45Nwho-72Nwho-108