Extension Cords - Chicago Electric HVLP-ELECTRIC 97750 Set Up And Operating Instructions Manual

Paint sprayer hvlp-electric
Table of Contents

Advertisement

2.
Double insulated tools may be used
in either of the 120 volt outlets shown
in the preceding illustration. (See
Outlets for 2-Prong Plug.)

Extension Cords

1.
Grounded
tools require a three wire
extension cord. Double Insulated
tools can use either a two or three
wire extension cord.
2.
As the distance from the supply outlet
increases, you must use a heavier
gauge extension cord. Using exten-
sion cords with inadequately sized
wire causes a serious drop in voltage,
resulting in loss of power and pos-
sible tool damage.
(See Table A.) The smaller the
gauge number of the wire, the greater
the capacity of the cord. For ex-
ample, a 14 gauge cord can carry a
higher current than a 16 gauge cord.
(See Table A.)
3.
When using more than one exten-
sion cord to make up the total length,
make sure each cord contains at
least the minimum wire size required.
(See Table A.)
4.
If you are using one extension cord
for more than one tool, add the
nameplate amperes and use the sum
to determine the required minimum
cord size. (See Table A.)
5.
If you are using an extension cord
outdoors, make sure it is marked with
the suffix "W-A" ("W" in Canada) to
indicate it is acceptable for outdoor
use.
6.
Make sure the extension cord is prop-
erly wired and in good electrical con-
dition. Always replace a damaged
SKU 97750
For technical questions, please call 1-800-444-3353.
extension cord or have it repaired by
a qualified electrician before using it.
7.
Protect the extension cords from
sharp objects, excessive heat, and
damp or wet areas.
RECOMMENdEd MINIMuM WIRE
gAugE FOR EXTENSION CORdS*
(120/240 VOLT)
NAMEPLATE
AMPERES
(at full load)
0 – 2.0
2.1 – 3.4
3.5 – 5.0
5.1 – 7.0
7.1 – 12.0
12.1 – 16.0
16.1 – 20.0
TABLE A
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V~
Volts Alternating Current
A
Amperes
No Load Revolutions per Minute
n 0 xxxx/min.
(RPM)
EXTENSION CORd
LENgTH
18
18
18
18
18
18
18
16
18
18
16
14
18
16
14
12
18
14
12
10
14
12
10
-
12
10
-
-
* Based on limiting the line
voltage drop to five volts at
150% of the rated amperes.
Page 7