Download Print this page

CANARMNA CEPD200 Manual

Ventilation fans

Advertisement

Quick Links

CANARMNA
www.canarmna.com
Model:CEPD140-4
CEPD150
WARNING
WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE
FOLLOWING:
a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
b). Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power
from being switching on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
c). Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and
standards, including fire-rated construction codes and standards.
d). Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by
the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE), and the local code authorities.
e). When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
f ). Ducted fans must always be vented to the outdoors.
g). Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit
(ceiling installation only).
h). This unit must be grounded.
i). Not for Use in Kitchens.
j). To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or
ceilings or into attics, crawl spaces, or garages.
k). WARNING: To Reduce The Risk Of Fire Or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.
l). The fan must not be installed in a ceiling thermally insulated to a value greater than R40.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
4. Please read specification label on product for further information and requirements.
*The manual in electronic format can be download in our company web, or obtained from our dealer.
CLEANING & MAINTENANCE
For quiet and efficient operation, long life, and attractive appearance - lower or remove grille and vacuum interior of unit with the
dusting brush attachment.The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive
or unusual noises, replace the motor with the exact service motor. The impeller should also be replaced.
OPERATION
S ee "CONNECT ELECTRICAL WIRING" for details.
The control box, located inside the fan housing:
(1) The low airflow knob adjusts the lower airflow from 40CFM up to the air flow
rate of the high fan speed (For CEPD140-4, the high fan speed is determined by
the toggle switch setting). The fan will not work when the knob turned between
OFF-40CFM.
(2) The time delay knob is adjustable from 3 to 30 minutes and will switch the fan
to the low speed setting after the switch is turned off for the set period of time.
(3) The toggle switch will adjust the upper fan speed setting from 80 to 140 CFM.
(Only for CEPD140-4)
Fan will run at the user-adjustable airflow rate continually;
turn on the switch, fan will turn to high speed;
turn off the switch, fan will continue to run at the certified airflow rate until the
user-adjustable time delay has passed, and then will automatically change to the
user-adjustable airflow rate.
Installer: Leave this manual with the homeowner.
CEPD200
READ AND SAVE THESE INSTRUCTIONS
VENTILATION FANS
Switch position
1 2 3
1 2 3
Airflow (CFM)
80
90
Switch position
1 2 3
1 2 3
1 2 3
Airflow (CFM)
80
90
110
30min
3min
Max.
OFF
Low airflow
knob
1 2 3
40CFM
70%
20min
10min
50%
time delay
S
T
knob
1 2 3
1 2 3
110
140
Control Box
1 2 3
140
Toggle switch
(only for CEPD140-4)
1 2 3
is the position of switch
Cod:0060302209

Advertisement

loading

Summary of Contents for CANARMNA CEPD200

  • Page 1 VENTILATION FANS CANARMNA www.canarmna.com CEPD200 Model:CEPD140-4 CEPD150 WARNING WARNING -TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a). Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer.
  • Page 2 PLAN THE INSTALLATION 1. Do not use in a cooking area. 2. Two ways to connect ductwork to a factory-shipped unit. INSULATION* ROOF CAP* (Place around and (with built-in over Fan Housing.) damper) POWER HOUSING CABLE* Keep duct runs short Seal gaps around Housing.
  • Page 3 CONNECT ELECTRICAL WIRING Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown. BLACK (BLK) WHITE (WHT) BROWN (BRN)
  • Page 4 WARRANTY This warranty covers all defects in workmanship or materials for: The mechanical and electrical parts contained in this product, for a period of 12 months, from the date of purchase. You must keep and be able to provide your original sales receipt as proof of the date of purchase. This warranty is covered the original retail purchaser of this product.

This manual is also suitable for:

Cepd150Cepd140-4