Download Print this page
Cateye Daylites II Solo HL-RC220 Instruction Manual
Cateye Daylites II Solo HL-RC220 Instruction Manual

Cateye Daylites II Solo HL-RC220 Instruction Manual

Cateye halogen rechargeable head lamp daylites ii [solo/twin] instruction manual hl-rc220(solo)/hl-rc230(twin)

Advertisement

Quick Links

®
E
Pb
6 v
READ ALL INSTRUCTIONS BEFORE FIRST USE
Thank you for purchasing the CAT EYE Daylits II rechargeable head lamp.
Before first use, thoroughly familiarize yourself with this manual so that you understand the lamp's safe and
correct operation. Please keep this manual for future reference.
NAMES
Please make sure that all the following parts are in the package.
* The package for Solo includes each 1 set of lamp unit(Spot Bulb), bracket, rubber pad; and the cord of the
remote switch is single (not furcated).
Lamp Unit
(spot-beam)
(wide-beam)
Battery Belt (2 sets)
Remote switch
FOR SAFE OPERATION (IMPORTANT)
• Never short-circuit the terminal of the battery and the plug of the battery charger. It may
cause the battery to overheat, resulting in fire or damage of the components.
• Securely connect the plug so that the light will not turn off while riding, or the cord will not hinder
riding.
• If the cord of the battery charger, the battery cord or battery unit is damaged, it must only be
replaced by the shop where this lamp kit was purchased, because special purpose tools are
required.
• The lamp unit becomes hot when turned on. Never touch the lamp unit or lens until thor-
oughly cooled. Injury may result.
• Use only the included battery charger for charging.
• Safely and properly dispose of the old battery accorfing to your local regulations when it
comes to the end of its useful life.
• This lamp kit is not intended for use by young children or infirm persons without supervi-
sion; young children should be supervised to ensure that they do not play with this appli-
ance.
• Take precautions against a sudden battery run-out. Carry a spare light or spare batteries
BEFORE FIRST USE:
Before first use, charge the battery fully following the instructions on [HOW TO CHARGE].
Before every use, charge the battery fully following the instructions on [HOW TO CHARGE].
When the battery kit is not in use for a long period, the lamp
to the self-discharge of the sealed-lead-acid battery.
bracket (H-30)
rubber pad
tighten
remote switch
screw
quick lever screw
lever
battery unit
fasten
bottle cage
battery belt
MOUNTING VARIATION
OF THE BATTERY UNIT
battery belt
battery belt
lamp unit
slide
lever
bracket
Halogen Rechargeable Head Lamp
Daylites II [Solo/Twin]
HL-RC220(Solo)/HL-RC230(Twin)
Instruction Manual
Design Pat. Pending
Copyright© 2000 CAT EYE Co., Ltd.
HLMRC22/23-011120 066640001
Battery Charger
(AD-1250)
Bracket (H-30)
Rubber Pad
Battery Unit (BA-220)
í
s operation time will be shortened due
HOW TO ATTACH THE BRACKET
[Use two brackets for Twin.]
1. Attach the bracket (H-30) to the handlebar using
the appropriate rubber pads provided.
2. Turn the quick lever (keeping it upright). Fix the
bracket securely by pulling up the lever. To loosen
the bracket, pull down the quick lever. Before use,
adjust the angle of the beam and the position of the
lamp unit, according to the instruction of "How to
Adjust Angle of Beam" in "HOW TO USE".
HOW TO ATTACH THE REMOTE SWITCH
Attach the remote switch onto the handlebar where it will
not hinder the braking and shifting operation. Attach the
remote switch using the appropriate rubber pads provided.
Note: To remove the remote switch, slide it to the left
while pushing the lever.
HOW TO MOUNT
Before connecting the cords, mount the battery unit
and lamp unit onto the right places.
Installing the Battery Unit
Insert the battery unit into your bottle cage. Secure it
with the battery belts.
Note: The battery unit might jump out of the bottle
cage during ride. Be sure that it is tightly
and firmly fixed.
Note: The battery unit may not fit all kinds of bottle
cages.
The battery unit also can be attached under the top
tube or along the seat post using the battery belt. (See
"MOUNTING VARIATION OF THE BATTERY UNIT")
Mounting the Lamp Unit
Warning!: Never touch the lamp body until it is
thoroughly cooled. You may get burnt.
• To mount the lamp body, slide it backward onto the
bracket until it clicks into position.
• To remove the lamp body, slide it forward while
pushing the lever.
cord reel
battery unit
lamp unit
4
1 2
from battery unit
remote switch
angle of the beam
the home power
battery charger
outlet
(AD-1250)
jack
plug
Standard charging time
8-10
Precautions on seald-lead-acid battery
• If the light is kept on until the power is completely
gone, the performance of the battery is lowered
due to the overdischarge of the sealed-lead-acid
battery. When the light gets dim, turn off the lamp
immediately and charge the battery.
• A long period of non-use will lower the voltage
of the battery due to natural self-discharge. If
the light is kept on until the power is completely
lamp body
bulb
waterproof
packing
lock ring
pull
rotate
8A fuse
fuse case
SPARE PARTS
LAMP BODY
H-30
#534-0560N
#533-8780
Lamp Body
Bracket (H-30)
6v-10W/WIDE
6v-10W/SPOT
#534-0580
#534-0581
6V-10W Wide Bulb 6V-10W Spot Bulb
SPECIFICATIONS
Bulb:
6V-10W Halogen Bulb
Battery:
BA-220
Sealed-Lead-Acid Battery 6V 4.2AH
Charger:
CAT EYE Battery Charger AD-1250
Operation Time: Solo
10W (HI):
5W(LOW): approx. 3 hours
Twin
10W+10W approx. 1 hour
10W
Charging Time: 8 to 10 hours
Temperature Range:
Charging:
0 C - 30 C
Operating:
–15 C - 45 C
Recharge/Discharge Number of Times:
at least 150 times (until rated capacity
drops to 50%)
* The specifications and design are subject to change
without notice.
Connecting Cord
Connect the jack of the remote switch and the plug of the battery
unit. Then connect the plug of the remote switch and lamp unit.
Wind the cord round the frame so that it will not hinder riding.
Note: In case of Twin, there are two kinds of beams – wide
and spot.
Note: Securely connect the jack to the plug.
remote
switch
HOW TO USE
ON/OFF
The remote switch controls the operation of the lamp unit.
•Twin (HL-RC230) ----- Button 1: on/off of lamp1
Button 2: on/off of lamp2
•Solo (HL-RC220) ----- Button 1: 10W(HI)/5W(LOW)
Button 2: on/off
Note: 5-watt beam is produced by adjusting the voltage of
10 watt output.
How to Adjust Angle of Beam
Adjust the angle of the beam downward (as shown in the
figure ). The light is also adjusted 10 horizontally.
(To adjust the angle, pull down the quick lever)
HOW TO CHARGE
Use only the provided battery charger. The charger is
only for indoor use.
1. Unplug the battery unit.
battery unit
2. Connect the plug of the battery unit with the battery
charger (AD-1250). Plug the battery charger with the
home power outlet.
* Standard charging time is 8 to 10 hours. (Depending on
the capacity of the battery, the charging time will vary.) Be
careful not to charge it for more than 10 hours. Over-
charge will damage the battery.
Note: The charging time and the operation time may vary
hours
depending on the use environment.
gone (which is called "overdischarge"), it may
shorten the battery life. Even when you do not use
the lamp kit, charge the battery every few months.
• Do not charge the battery for more than 10 hours.
• If the lamp set does not serve the proper running
time even though the battery is fully charged, the
battery may have reached the end of its useful
life. Replace it with a new battery unit (BA-220).
HOW TO REPLACE THE BULB
When replacing the bulb, be sure that the bulb and the lamp
body have cooled.
Use only the CAT EYE 6V-10W Halogen Bulb (product code
#534-0580/534-0581).
1. Remove the lock ring by turning it counterclockwise.
2. Remove the bulb and replace with a new one.
Note: Do not rotate the bulb but pull it straight out.
3. Tighten the lock ring securely while being careful of the waterproof
packing.
HOW TO REPLACE THE FUSE
A fuse will cut the circuit when malfunction occurs. Remove the malfunction.
Note: If the fuse continues to burn, call the appropriate service center
for assistance.
1. Loosen the screws of the battery unit and carefully open the battery case.
2. Open the fuse case inside. Replace the fuse (8A) with a new one.
Note: Do not pull the cord inside of the battery forcibly.
Note: Do not short-circuit the terminal of the battery.
REMOTE SWITCH-T
REMOTE SWITCH-S
#534-0571N
#534-0570N
Remote switch (Twin)
Remote switch (Solo)
AD-1250
#534-0593 for U.S.A & Canada
#534-0591 for Europe
#534-0590 for United Kingdom
#534-0592 for Australia
8A FUSE
BA-220
Battery Charger
#0534-0573
#534-0574N
8A Fuse
Battery Unit
LIMITED WARRANTY
2-Year Warranty:
Only Lamp/Remote switch and Battery Charger
(Excluding bulb and battery)
If trouble or damage occurs during normal use, the product will be
approx. 2 hours
repaired or replaced free of charge. Type your name, address, date of
purchase and the situation of trouble clearly, and send it to the
appropriate service center together with the product. Insurance, handling
approx. 2 hours
and transportation charges shall be borne by the customer. After being
repaired or replaced, the product will be shipped back to the customer.
Address for service:
2-8-25 Kuwazu, Higashi Sumiyoshi-ku Osaka 546-0041 JAPAN
Attention: CAT EYE CO., LTD. Customer Service Section
Phone: 81-6-6719-7781 Fax: 81-6-6719-2362
Service & Research Address for United States Consumers:
CAT EYE Service & Research Center
1705 14th St. #115 Boulder, CO 80302
Phone: 303-443-4595
Toll Free: 800-5CATEYE(800-522-8393)
Fax: 303-473-0006
e-mail: service@cateye.com
web site: http://www.cateye.com
BATTERY BELT
#534-0572
Battery belt

Advertisement

loading

This manual is also suitable for:

Daylites ii twin hl-rc230