Basic System Diagram - Samsung SSC-2000 User Manual

System keyboard
Table of Contents

Advertisement

7) Connecting PC based DVR
(Applicable to the SPR Smart View V2.3 over)
- Connect SSC-2000 through the RS-485 port in the back of PC BASED
DVR.
- Connect SIGNAL (+) in the RS-485 port of PC BASED DVR with Tx (+)
of SSC-2000.
- Connect SIGNAL (-) in the RS-485 port of PC BASED DVR with Tx (-)
of SSC-2000.
Connect a PC in which a terminal emulation program is installed to
update the S/W of this equipment. Here, you may use the RS-232C
for connection.
RS-232C 9PIN(Connector Arrangement)
PIN NUMBER
2
3
5
1, 4, 6~9
• Please refer to "RS-232 Communication Setup (GB-13)" of "Chapter 5.
Menu Setup" for RS-232 communication setup.
• It is possible to connect and use max. 32 keyboards simultaneously.
• Refer to the "ADDRESS SET" part in "RS-232 Communication Setup
(GB-13)" of "Chapter 5. Menu Setup" for the setting of keyboard
communication.
• Do not use together with the SSC-1000 because it is different with the
SSC-1000 in communication method.
MENU
DVR
MON
CAN
MUX
MODESEQUENCE
M E N U M O N C A N M U X M O D E
PIN SPECIFICATIONS
TXD (TRANSMITTED DATA)
RXD (RECEIVED DATA)
SG (SIGNAL GROUND)
NO CONNECTION
- Connect the Tx (+) of SSC-2000 port with the Tx (+) of another SSC-2000.
- Connect the Tx (-) of SSC-2000 RS-485 port with the Tx (-) of another
SSC-2000.
- Connect the Tx (+) of SSC-2000 with the Rx (+) of another SSC-2000.
- Connect the Tx (-) of SSC-2000 with the Rx (-) of another SSC-2000.
- Connect the Rx (+) of SSC-2000 with the Tx (+) of another SSC-2000.
- Connect the Rx (-) of SSC-2000 with the Tx (-) of another SSC-2000.
• Do not use together with the SSC-1000 because it is different with the
SSC-1000 in communication method.
When using the system by connecting with SCC-931T Version 1.4, make the
address of devices connected to the system different.