Download Print this page

Carrier TB-NAC Installation Instructions Manual

Base series non-programmable thermostat

Advertisement

Quick Links

TB---NAC
TB---NHP
Base Series
Non ---Programmable Thermostat
Base Non ---Programmable Thermostat
NOTE: Read the entire instruction manual before starting the
installation.
TABLE OF CONTENTS
SAFETY CONSIDERATIONS
INTRODUCTION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSTALLATION CONSIDERATIONS
INSTALLATION
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Step 1 — Thermostat Location
Step 2— Install Thermostat
Step 3 — Set Thermostat Configuration
Step 4 — Thermostat Operation
Step 5 — Check Thermostat Operation
WIRING DIAGRAMS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SAFETY CONSIDERATIONS
Read and follow manufacturer instructions carefully. Follow all
local electrical codes during installation. All wiring must conform
to local and national electrical codes. Improper wiring or
installation may damage thermostat.
Recognize safety information. This is the safety- -alert symbol
When you see this symbol on the equipment and in the instruction
manual, be alert to the potential for personal injury. Understand the
signal words DANGER, WARNING, and CAUTION.
These words are used with the safety- -alert symbol. DANGER
identifies the most serious hazards which will result in severe
personal injury or death. WARNING signifies a hazard which
Installation Instructions
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
could result in personal injury or death. CAUTION is used to
identify unsafe practices which may result in minor personal injury
or product and property damage. NOTE is used to highlight
suggestions which will result in enhanced installation, reliability, or
operation.
The
Base
Series
non- -programmable, manual changeover wall mount thermostat.
This thermostat uses a single setpoint to maintain and control room
temperature in both the heating and air conditioning modes. The
thermostat is designed to maintain +/- - 2_F accuracy. No batteries
are required; temperature, fan, mode, and installer configuration
settings are preserved with power off.
INSTALLATION CONSIDERATIONS
Air Conditioner Model
TB- -NAC, Base Series Model air conditioner thermostat, may be
A07108
wired with or without connecting a common wire between the
indoor equipment and the thermostat. However, it is recommended
to use a common wire whenever possible. Without a common wire
this thermostat becomes "power stealing." This means it will need
to steal a small amount of power from the equipment to which it is
connected.
NOTE:
Not all HVAC equipment is compatible with power
PAGE
stealing type thermostats. All Carrier equipment is directly
1
compatible with this thermostat except the Thermostat Conversion
Kit, Part #TSTATXXCNV10. For all non- -Carrier equipment,
1
consult the system equipment Installation Instructions before
1
applying this thermostat in a power stealing manner.
1
Heat Pump Model
1
TB- -NHP, Base Series Model heat pump thermostat, is compatible
2
with all Carrier heat pump systems. It is NOT power stealing and
MUST have both the R and C terminals connected to operate
2
properly. This thermostat uses a green LED to indicate auxiliary
3
heat and emergency heat operation.
3
4
Step 1 — Thermostat Location
Thermostat should be mounted:
Approximately 5 ft (1.5m) from floor.
S
Close to or in a frequently used room, preferably on an
S
inside partitioning wall.
On a section of wall without pipes or duct work.
S
.
Thermostat should NOT be mounted:
Close to a window, on an outside wall, or next to a door
S
leading to the outside.
Exposed to direct light and heat from the sun, a lamp,
S
fireplace, or other heat- -radiating object which may cause
a false reading.
INTRODUCTION
thermostat
is
an
electronic
INSTALLATION
24VAC,

Advertisement

loading

Summary of Contents for Carrier TB-NAC

  • Page 1 Heat Pump Model TB- -NHP, Base Series Model heat pump thermostat, is compatible with all Carrier heat pump systems. It is NOT power stealing and MUST have both the R and C terminals connected to operate ....
  • Page 2 HP or PH controls 1 speed heat pump with 1 stage of aux heat. AC or PC controls 1 speed air conditioner with one stage of heat. Note that this option allows a HP thermostat to be converted to control an AC system.
  • Page 3: Equipment Configuration

    Staging Timer If the thermostat is a heat pump model, it has 2- -stage heat capability. With HP operation, there is a 15- -minute delay between the first and second stages of heat. The Y output will energize first, then 15 minutes later, W is allowed to come on if the thermostat determines it is not satisfying the demand.
  • Page 4: Wiring Diagrams

    Fig. 1 - - A/C Thermostat Typical Installation Fig. 2 - - HP Thermostat Typical Installation Catalog No: TB---NAC ---1SI Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 02/07 Replaces: NEW...
  • Page 5 TB---NHP Base Series Non ---Programmable Thermostat Homeowner’s Guide Base Non ---Programmable Thermostat 1. To Select the Mode: Use the H/C button to move between the choices. OFF, HEAT, COOL, or EMHT will appear on the display. EMHT will only appear on heat pump models.
  • Page 6: Warranty Conditions

    THERMOSTAT LIMITED WARRANTY FIVE- -YEAR LIMITED WARRANTY - - Carrier Corporation (hereinafter referred to as “Company”) warrants this product to be free from defects in material and workmanship. If a defect is found within five years from date of original installation of product (whether or not actual use begins on that date) Company will provide a new or remanufactured part, at Company’s sole option, to replace any defective part, without...

This manual is also suitable for:

Tb-nhp