7½- to 12½-ton self-contained packaged heat pump

Advertisement

C
/ H
ooling
eating
90,000 - 118,000 Btu/
Standard Features
• R-410A chlorine-free refrigerant
• High-efficiency scroll compressors
• Two-stage cooling
• Copper tube / aluminum fin coils
• Contactor with lugs
• High-capacity, steel-cased filter drier
• Single-point entry
• 24-volt terminal strip
• Convertible
• Easy to service
• Built-in filter rack with standard 2" filters
• Bottom utility entry
• AHRI Certified; ETL Listed
Cabinet Features
• Heavy-gauge, galvanized-steel cabinet with
UV-resistant powder-paint finish
• Full Perimeter Rail
• Curb Fit
* Complete warranty details available from your local dealer or at www.goodmanmfg.com.
SS-CPH90-150
C
:
aPaCitieS
H
www.goodmanmfg.com
CPH C
7½-
12½-t
to
P
aCkaged
uP to
uP to
Contents
Nomenclature .................................................................... 2
Product Specifications ....................................................... 3
Expanded Heating Data . ................................................... 7
Expanded Cooling Data ..................................................... 8
Airflow Data .....................................................................16
Heat Kit Electrical Data . .................................................. 20
Dimensions ......................................................................24
Wiring Diagrams ............................................................. 28
Accessories ......................................................................34
ommerCial
S
-C
on
elf
ontained
H
P
eat
umP
11.5 eer
3.5 CoP
12/11
Supersedes 10/11

Advertisement

loading

Summary of Contents for Goodman CPH COMMERCIAL SS-CPH90-150

  • Page 1: Table Of Contents

    ooling eating aPaCitieS 90,000 — 118,000 Btu/ Standard Features • R-410A chlorine-free refrigerant • High-efficiency scroll compressors • Two-stage cooling • Copper tube / aluminum fin coils • Contactor with lugs • High-capacity, steel-cased filter drier • Single-point entry • 24-volt terminal strip • Convertible • Easy to service • Built-in filter rack with standard 2” filters • Bottom utility entry • AHRI Certified; ETL Listed Cabinet Features • Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish • Full Perimeter Rail • Curb Fit * Complete warranty details available from your local dealer or at www.goodmanmfg.com.
  • Page 2: Nomenclature

    roduCt PeCifiCationS omenClature   Brand Commercial Configura<on Packaged   U nit Applica<on Cooling Gas   H eat Heat   P ump Nominal   G ross   C ooling   C apacity   3   T ons 8½   T ons 4  ...
  • Page 3 — 7½ t roduCt PeCifiCationS Cooling Capacity Total BTU/h Sensible BTU/h EER / IEER IPLV Decibels AHRI Reference #s Heating Capacity BTU/h / COP (47° F) BTU/h / COP (17° F) Evaporator Motor / Coil Motor Type Indoor Nominal CFM Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling)
  • Page 4 roduCt PeCifiCationS — 8½ t roduCt PeCifiCationS Cooling Capacity Total, BTU/h Sensible BTU/h EER / IEER Decibels ARI Reference #s Heating Capacity BTU/h (47°F) COP (47°F) BTU/h (17°F) COP (17°F) Evapoartor Motor / Coil Motor Type Indoor Nominal CFM Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size (Qty)
  • Page 5 — 10 t roduCt PeCifiCationS Cooling Capacity Total BTU/h Sensible BTU/h EER / IEER Decibels Heating Capacity BTU/h (47° F) COP (47°F) BTU/h (17° F) COP (17°F) Evaporator Motor / Coil Motor Type Indoor Nominal CFM Indoor motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Expansion Device...
  • Page 6 roduCt PeCifiCationS — 12½ t roduCt PeCifiCationS Cooling Capacity Total, BTU/h Sensible BTU/h EER / IPLV Decibels ARI Reference #s Heating Capacity BTU/hr (47°F) COP (47°F) BTU/hr (17°F) COP (17°F) Evapoartor Motor / Coil Motor Type (Belt Drive) Indoor Nominal CFM Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling)
  • Page 7: Expanded Heating Data

    xPanded eating CPH090 114.4 108.3 101.9 95.3 91.0 35.3 33.4 31.5 29.4 28.1 8.22 8.06 7.91 7.75 7.66 Amps 30.2 28.4 26.9 25.6 24.9 4.07 3.93 3.77 3.60 3.48 HI PR LO PR CPH102 128.2 121.4 114.2 106.8 102.0 34.9 33.1 31.1 29.1...
  • Page 8 roduCt PeCifiCationS — 7½ t xPanded ooling www.goodmanmfg.com SS-CPH90-150...
  • Page 9 roduCt PeCifiCationS — 7½ t xPanded ooling Cont SS-CPH90-150 www.goodmanmfg.com...
  • Page 10 roduCt PeCifiCationS — 8½ t xPanded ooling www.goodmanmfg.com SS-CPH90-150...
  • Page 11 roduCt PeCifiCationS — 8½ t xPanded ooling Cont SS-CPH90-150 www.goodmanmfg.com...
  • Page 12: Expanded Cooling Data

    roduCt PeCifiCationS — 10 t xPanded ooling www.goodmanmfg.com SS-CPH90-150...
  • Page 13 roduCt PeCifiCationS — 10 t xPanded ooling Cont SS-CPH90-150 www.goodmanmfg.com...
  • Page 14 roduCt PeCifiCationS — 12½ t xPanded ooling www.goodmanmfg.com SS-CPH90-150...
  • Page 15 roduCt PeCifiCationS — 12½ t xPanded ooling Cont SS-CPH90-150 www.goodmanmfg.com...
  • Page 16 roduCt PeCifiCationS — 7½ t irflow ESP, In CFM RPM BHP CFM RPM BHP 3400 3303 1.41 2871 2838 1.23 High-Static Belt Drive — Down Shot (A Models only) ESP, In CFM RPM BHP CFM RPM BHP 3381 1119 2.22 2890 1080 1.78 3089 1129 2.04 ESP, In CFM RPM BHP...
  • Page 17 — 8½ t irflow ESP, In CFM RPM BHP CFM RPM BHP 3250 3153 1.38 2721 2688 1.20 ESP, In CFM RPM BHP CFM RPM BHP 3231 1116 2.19 2740 1077 1.75 3256 1156 2.31 2939 1126 2.01 ESP, In CFM RPM BHP CFM RPM BHP 3630...
  • Page 18 roduCt PeCifiCationS — 10 t irflow ESP, In CFM RPM BHP CFM RPM BHP 4445 4418 4073 4064 2.09 3518 3555 1.77 ESP, In CFM RPM BHP CFM RPM BHP 4550 1064 2.83 4290 1042 2.56 3913 1006 2.13 4327 1087 2.73 3990 1057 2.37 4652 1148 3.33 4023 1105 2.58 4306 1162 3.05 ESP, In...
  • Page 19: Airflow Data

    — 12½ t irflow ESP (in W.C.) 5514 2.92 5349 5204 2.69 4919 4830 2.42 4649 4497 2.19 4264 ESP (in W.C.) 5776 4.64 5510 5465 4.30 5199 5145 3.97 4871 4805 3.63 4565 4429 3.27 4233 ESP (in W.C.) 5871 3.20 5639...
  • Page 20 roduCt PeCifiCationS — 7½ t leCtriCal Model and MCA¹ Heat Kit Usage at 208 / 240V CPH090***3B*** EHK3-16 74 / 85 EHK3-30 113 / 130 EHK3-45 147 / 169 Model and MCA¹ Heat Kit Usage at 208 / 240V CPH090***4B*** EHK4-16 EHK4-30 EHK4-45...
  • Page 21 — 8½ t leCtriCal Model and MCA¹ Heat Kit Usage at 240V CPH102***3B*** EHK3-16 EHK3-30 EHK3-45 Model and MCA¹ Heat Kit Usage at 480V CPH102***4B*** EHK4-16 EHK4-30 EHK4-45 Model and MCA¹ Heat Kit Usage at 575V CPH102***7B*** EHK7-16 EHK7-30 EHK7-45 ¹...
  • Page 22 roduCt PeCifiCationS — 10 t leCtriCal Model and MCA¹ at Heat Kit Usage 208 / 240V CPH120***3B*** EHK3-16 81 / 94 EHK3-30 122 / 139 EHK3-45 154 / 178 Model and MCA¹ at Heat Kit Usage 208 / 240V CPH120***3H*** EHK3-16 82 / 95 EHK3-30...
  • Page 23: Heat Kit Electrical Data

    — 12½ t leCtriCal Model and MCA¹ at Heat Kit Usage 208 / 240V CPH150***3B*** EHK3-16 EHK3-30 EHK3-45 Model and MCA¹ at Heat Kit Usage 208 / 240V CPH150***4B*** EHK4-16 EHK4-30 EHK4-45 Model and MCA¹ at Heat Kit Usage 208 / 240V CPH150***7B*** EHK7-16 EHK7-30...
  • Page 24: Dimensions

    roduCt PeCifiCationS APPENDIX C UNIT DIMENSIONS imenSionS 12.5 52 7/8" 52 7/8" 52 7/8" 58 7/8" 28⅜” 7⅜” 28 3/8” 7 3/8” 13⅞” 13 7/8” SUPPLY 6 1/4” 6¼” Horizontal Discharge NOTE For horizontal discharge, remove the supply and return duct covers and place them over the vertical discharge return and supply openings.
  • Page 25 learanCeS Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48” on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake. leCtriCal ntranCe oCationS 11⅝” High-Voltage Entrance ” Low-Voltage Entrance 3” SS-CPH90-150 48” 36” Min. 75” Dimples Mark Drill Locations www.goodmanmfg.com roduCt PeCifiCationS 48” 48”...
  • Page 26 roduCt PeCifiCationS — r nStallation igging Provisions for forks have been included in the unit base frame. No other fork locations are approved. • Unit must be lifted by the four lifting holes located at the base frame corners. • Lifting cables should be attached to the unit with shackles. • The distance between the crane hook and the top of the unit must not be less than 60”. • Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rig- ging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual. Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual.
  • Page 27 nStallation Cont 3-d V 92¼ 15⅜ x 31⅛ Supply Opening 14⅝ x 38⅜ Return Opening SS-CPH90-150 Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package.
  • Page 28 roduCt PeCifiCationS — CPH090-120***3B/ 4B iring iagram for modelS witH Serial numBerS 0907 and Below Wiring is subject to change. Always ⚠ refer to the wiring diagram or the unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power arning sources may be present.
  • Page 29 — CPH090-120***3B/ 4B ( iring iagram for modelS witH Serial numBerS 0907 and Below Wiring is subject to change. Always ⚠ refer to the wiring diagram or the unit for the most up-to-date wiring. SS-CPH90-150 Cont High Voltage: Disconnect all power before servicing or installing this unit. Multiple power arning sources may be present.
  • Page 30 roduCt PeCifiCationS — CPH090-120***3B/ 4B/ 7B*** iring iagram EBTDR XFMR-R XFMR-C SPEED LVDR HVDR DFT2 DFT1 RVC1 Wiring is subject to change. Always ⚠ refer to the wiring diagram or the unit for the most up-to-date wiring. REPLACE JUMPER WITH SMOKE/FIRE DETECTOR SSHR PLF 1...
  • Page 31 — CPH090-120***3B/ 4B/ 7B*** ( iring iagram SUPPLY VOLTAGE 208-240/460/575/3/60 COMP1 RCCF2 RCCF COMP2 208-240V OR APPROPRIATE INPUT VOLTAGE EBTDR EBTDR HVDR DFT1 EBTDR DFT2 RVC1 LVDR LPS1 HPS1 SSHR SEE NOTE 4 THERMOSTAT SS-CPH90-150 Cont COMPONENT LEGEND BLOWER CONTACTOR COMPRESSOR CONTACTOR CONDENSER MOTOR CONDENSER MOTOR CONTACTOR...
  • Page 32 roduCt PeCifiCationS — CPH150***3B/ 4B/ 7B*** iring iagram EBTDR XFMR-R XFMR-C SPEED LVDR L2 L3 HVDR DFT2 DFT1 RVC1 3 BL REPLACE JUMPER WITH SMOKE/FIRE DETECTOR NOTE 3 SSHR PLF 1 RCCF2 T3 T2 COMP2 LPS2 RVC2 RCCF1 LPS1 COMP1 www.goodmanmfg.com NOTE #2 WH YL...
  • Page 33 — CPH150***3B/ 4B/ 7B*** ( iring iagram SUPPLY VOLTAGE 208-240/460/575/3/60 COMP1 RCCF2 RCCF COMP2 208-240V OR APPROPRIATE INPUT VOLTAGE EBTDR EBTDR HVDR DFT1 EBTDR DFT2 RVC1 LVDR LPS1 HPS1 SSHR SEE NOTE 4 THERMOSTAT Wiring is subject to change. Always ⚠...
  • Page 34 roduCt PeCifiCationS CCeSSorieS Item # 14CURB90150 14" Roof Curb 25FD90150 25% Manual Fresh Air Damper 25MFD90150 25% Motorized Fresh Air Damper DNBBS90150 Burglar Bar Sleeves: includes Supply & Return CDK120 Concentric Duct Kit CDK150 Concentric Duct Kit CDK90102 Concentric Duct Kit HailGD02 Condenser Coil Hail Guard HailGD05...
  • Page 35 roduCt PeCifiCationS oteS SS-CPH90-150 www.goodmanmfg.com...
  • Page 36 roduCt PeCifiCationS oteS Goodman Manufacturing Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2010 • Goodman Manufacturing Company, L.P. • Houston, Texas • Printed in the USA. www.goodmanmfg.com SS-CPH90-150...

This manual is also suitable for:

Cph090 seriesCph120 seriesCph150 series