roduCt PeCifiCationS omenClature Brand Commercial Configura<on Packaged
U nit Applica<on Cooling Gas
H eat Heat
P ump Nominal
G ross
C ooling
C apacity
3
T ons 8½
T ons 4
...
Page 3
— 7½ t roduCt PeCifiCationS Cooling Capacity Total BTU/h Sensible BTU/h EER / IEER IPLV Decibels AHRI Reference #s Heating Capacity BTU/h / COP (47° F) BTU/h / COP (17° F) Evaporator Motor / Coil Motor Type Indoor Nominal CFM Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling)
Page 4
roduCt PeCifiCationS — 8½ t roduCt PeCifiCationS Cooling Capacity Total, BTU/h Sensible BTU/h EER / IEER Decibels ARI Reference #s Heating Capacity BTU/h (47°F) COP (47°F) BTU/h (17°F) COP (17°F) Evapoartor Motor / Coil Motor Type Indoor Nominal CFM Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Filter Size (Qty)
Page 5
— 10 t roduCt PeCifiCationS Cooling Capacity Total BTU/h Sensible BTU/h EER / IEER Decibels Heating Capacity BTU/h (47° F) COP (47°F) BTU/h (17° F) COP (17°F) Evaporator Motor / Coil Motor Type Indoor Nominal CFM Indoor motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling) Expansion Device...
Page 6
roduCt PeCifiCationS — 12½ t roduCt PeCifiCationS Cooling Capacity Total, BTU/h Sensible BTU/h EER / IPLV Decibels ARI Reference #s Heating Capacity BTU/hr (47°F) COP (47°F) BTU/hr (17°F) COP (17°F) Evapoartor Motor / Coil Motor Type (Belt Drive) Indoor Nominal CFM Indoor Motor FLA (Cooling) Horsepower - RPM Piston Size (Cooling)
Page 20
roduCt PeCifiCationS — 7½ t leCtriCal Model and MCA¹ Heat Kit Usage at 208 / 240V CPH090***3B*** EHK3-16 74 / 85 EHK3-30 113 / 130 EHK3-45 147 / 169 Model and MCA¹ Heat Kit Usage at 208 / 240V CPH090***4B*** EHK4-16 EHK4-30 EHK4-45...
Page 21
— 8½ t leCtriCal Model and MCA¹ Heat Kit Usage at 240V CPH102***3B*** EHK3-16 EHK3-30 EHK3-45 Model and MCA¹ Heat Kit Usage at 480V CPH102***4B*** EHK4-16 EHK4-30 EHK4-45 Model and MCA¹ Heat Kit Usage at 575V CPH102***7B*** EHK7-16 EHK7-30 EHK7-45 ¹...
Page 22
roduCt PeCifiCationS — 10 t leCtriCal Model and MCA¹ at Heat Kit Usage 208 / 240V CPH120***3B*** EHK3-16 81 / 94 EHK3-30 122 / 139 EHK3-45 154 / 178 Model and MCA¹ at Heat Kit Usage 208 / 240V CPH120***3H*** EHK3-16 82 / 95 EHK3-30...
— 12½ t leCtriCal Model and MCA¹ at Heat Kit Usage 208 / 240V CPH150***3B*** EHK3-16 EHK3-30 EHK3-45 Model and MCA¹ at Heat Kit Usage 208 / 240V CPH150***4B*** EHK4-16 EHK4-30 EHK4-45 Model and MCA¹ at Heat Kit Usage 208 / 240V CPH150***7B*** EHK7-16 EHK7-30...
roduCt PeCifiCationS APPENDIX C UNIT DIMENSIONS imenSionS 12.5 52 7/8" 52 7/8" 52 7/8" 58 7/8" 28⅜” 7⅜” 28 3/8” 7 3/8” 13⅞” 13 7/8” SUPPLY 6 1/4” 6¼” Horizontal Discharge NOTE For horizontal discharge, remove the supply and return duct covers and place them over the vertical discharge return and supply openings.
Page 25
learanCeS Maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible removal of fan shaft, coil, electric heat, and gas furnace. Leave a clearance of 48” on all other sides of the unit for possible compressor removal or service access, and to ensure proper ventilation and condenser airflow. Do not install the unit beneath any obstruction. Install the unit away from all building exhausts to inhibit ingestion of exhaust air into the unit’s fresh-air intake. leCtriCal ntranCe oCationS 11⅝” High-Voltage Entrance ” Low-Voltage Entrance 3” SS-CPH90-150 48” 36” Min. 75” Dimples Mark Drill Locations www.goodmanmfg.com roduCt PeCifiCationS 48” 48”...
Page 26
roduCt PeCifiCationS — r nStallation igging Provisions for forks have been included in the unit base frame. No other fork locations are approved. • Unit must be lifted by the four lifting holes located at the base frame corners. • Lifting cables should be attached to the unit with shackles. • The distance between the crane hook and the top of the unit must not be less than 60”. • Two spreader bars must span over the unit to prevent damage to the cabinet by the lift cables. Spreader bars must be of sufficient length so that cables do not come in contact with the unit during transport. Remove wood struts mounted beneath unit base frame before setting unit on roof curb. These struts are intended to protect unit base frame from fork lift damage. To remove the struts, extract the sheet metal retainers and pull the struts through the base of the unit. Refer to rig- ging label on the unit. Important: If using bottom discharge with roof curb, duct-work should be attached to the curb prior to installing the unit. Duct-work dimensions are shown in Roof Curb Installation Instructions Manual. Refer to the Roof Curb Installation Instructions for proper curb installation. Curbing must be installed in compliance with the National Roofing Contractors Association Manual.
Page 27
nStallation Cont 3-d V 92¼ 15⅜ x 31⅛ Supply Opening 14⅝ x 38⅜ Return Opening SS-CPH90-150 Curb installations must comply with local codes and should follow the established guidelines of the National Roofing Contractors Association. Proper unit installation requires that the roof curb be firmly and permanently attached to the roof structure. Check for adequate fastening method prior to setting the unit on the curb. Full perimeter roof curbs are available from the factory and are shipped unassembled. The installing contractor is responsible for field assembly, squaring, leveling, and mounting on the roof structure. All required hardware necessary for the assembly of the sheet metal curb is included in the curb accessory package.
Page 28
roduCt PeCifiCationS — CPH090-120***3B/ 4B iring iagram for modelS witH Serial numBerS 0907 and Below Wiring is subject to change. Always ⚠ refer to the wiring diagram or the unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power arning sources may be present.
Page 29
— CPH090-120***3B/ 4B ( iring iagram for modelS witH Serial numBerS 0907 and Below Wiring is subject to change. Always ⚠ refer to the wiring diagram or the unit for the most up-to-date wiring. SS-CPH90-150 Cont High Voltage: Disconnect all power before servicing or installing this unit. Multiple power arning sources may be present.
Page 30
roduCt PeCifiCationS — CPH090-120***3B/ 4B/ 7B*** iring iagram EBTDR XFMR-R XFMR-C SPEED LVDR HVDR DFT2 DFT1 RVC1 Wiring is subject to change. Always ⚠ refer to the wiring diagram or the unit for the most up-to-date wiring. REPLACE JUMPER WITH SMOKE/FIRE DETECTOR SSHR PLF 1...
Page 31
— CPH090-120***3B/ 4B/ 7B*** ( iring iagram SUPPLY VOLTAGE 208-240/460/575/3/60 COMP1 RCCF2 RCCF COMP2 208-240V OR APPROPRIATE INPUT VOLTAGE EBTDR EBTDR HVDR DFT1 EBTDR DFT2 RVC1 LVDR LPS1 HPS1 SSHR SEE NOTE 4 THERMOSTAT SS-CPH90-150 Cont COMPONENT LEGEND BLOWER CONTACTOR COMPRESSOR CONTACTOR CONDENSER MOTOR CONDENSER MOTOR CONTACTOR...