Wiring and preparation
4. Make a hole of at least 20 millimeters in diameter through the deck or bulkhead to run the sig-
nal cable. (To prevent electrical interference, do not run the signal cable near other electrical
equipment. Do not run the cable in parallel to power cables.) Set the cable through the hole.
Close the hole with the sealing compound for waterproofing.
5. Remove three shield covers in the radome.
6. Loosen four screws and remove the cable clamping plate and the gasket.
Screws
7 pcs.
Shield cover
Screws
7 pcs.
7. Set the signal cable through the hole at the bottom of the radome base.
8. Fasten the signal cable with the cable clamping plate and gasket. Connect the shield and vinyl
wire to the ground by one of the screws of the cable clamping plate.
9. Connect the wire to the RF unit, referring to the illustration on the next page.
Effective
thread length
25 mm
Flat
washer
Spring
washer
Apply silicone sealant.
How to fasten the radome base to the platform
Shield cover
Screws
6 pcs.
Shield cover
Antenna unit, inside view
Antenna base plate
Gasket
Radome
5 - 10 mm
Platform
M10 x 25
Hex bolt
Screws
4 pcs.
Cable clamping plate
Gasket