Devices
PVS 204SA
External power supply ................. 100 VAC to 240 VAC, 50/60 Hz, external, autoswitchable; to 12 VDC, 3 A, regulated
Power input requirements ........... 12 VDC, 0.97 A (typical)
Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Enclosure type .............................. Metal
Enclosure dimensions .................. 1.7" H x 8.7" W x 3.0" D (1U high, half rack wide) (4.3 cm H x 22.1 cm W x 7.6 cm D)
Product weight .............................. 2.5 lbs (1.1 kg), plus power supply 0.8 lbs (0.4 kg)
Vibration ........................................ ISTA 1A in carton (International Safe Transit Association)
Listings............................................ UL, CUL, (UL rated for use in plenum airspaces: meets UL 2043 for heat and smoke release,
Compliances ................................... CE, FCC Class A, VCCI, AS/NZS, ICES
MTBF ............................................... 30,000 hours
MLC 104 IP Plus
Power .............................................. Supplied by the PVS 204SA twisted pair receiver/switcher
Power input requirements ........... 12 VDC, 0.19 A (0.305 A if used with an optional IRCM-DV+)
Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Rack mount .................................... Wall and furniture mountable
Enclosure type ............................... Metal
Enclosure dimensions ................... MLC 104 IP Plus faceplate 4.5" H x 4.6" W x 0.1" D (11.4 cm H x 11.7 cm W x 0.3 cm D)
Product weight .............................. 1.9 lbs (0.9 kg)
Vibration ......................................... ISTA 1A in carton (International Safe Transit Association)
Listings............................................ UL, CUL
Compliances ................................... CE, FCC Class A, VCCI, AS/NZS, ICES, Section 508 of the Rehabilitation Act
MTBF ............................................... 30,000 hours
PVT CV D and PVT RGB D
Power .............................................. Supplied by the PVS 204SA twisted pair receiver/switcher
Power input requirements ........... 5 VDC, 0.10 A for PVT CV D; 5 VDC, 0.15 A for PVT RGB D
Temperature/humidity ................ Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing
Mount..............................................
Enclosure type ............................... Metal
Enclosure dimensions ...................
Product weight
............................ 0.2 lbs (0.1 kg)
Vibration ......................................... ISTA 1A in carton (International Safe Transit Association)
Listings............................................ UL, CUL
Compliances ................................... CE, FCC Class A, VCCI, AS/NZS, ICES
MTBF ............................................... 30,000 hours
N All nominal levels are at ± 10%
N Specifications are subject to change without notice.
2-32
PoleVault Systems Installation • Reference Information
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
excluding the power supply; meets UL 60065 for safety)
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
MLC 104 IP Plus device 2.7" H x 3.4" W x 1.8" D (6.9 cm H x 8.6 cm W x 4.6 cm D)
(Depth excludes knob and buttons. Fits some 2 gang boxes. Allow at least 1.9" [4.8 cm] depth
in the wall or furniture.)
(29 U.S.C. 794d)
Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing
Wall or furniture mountable with included Decora wall plate.
Faceplate 2.6
H x 1.3
W x 0.3
"
"
(fits the opening in a 1 gang Decora plate)
Device 2.6
"
H x 1.6
"
W x 0.7
(Depth excludes connectors, height excludes mounting tabs.)
D (6.6 cm H x 3.3 cm W x 0.7 cm D)
"
"
D (6.6 cm H x 4.1 cm W x 1.8 cm D)