• it is possible to rotate the optic by ±90° on the horizontal axis and orientate the
beam by ±10° on vertical plan, as shown on pict. 6, by acting on the lens.
MAINTENANCE
• it is essential a frequent cleaning of the glass and of the outer surface of the fixture
to avoid build up of mud and dirtiness resulting in dangerous overheating due to
uncorrect light and heath dissipation.
• important: in the event of damage to the H07RN-F cable, breakage of the screen,
infiltration of water, the appliance cannot be used. Disconnect it from the mains
supply and contact our company or our sales organization for replacement/repair
LED CIRCUIT REPLACEMENT - MAINTENANCE
. N
. B
T :
h
e
e
e l
c
r t
c i
l a
i c
c r
i u
c t
o
m
p
e l
sales network. The replacement must be done by a skilled electrician
Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial
number that recognizes the fixture.
Concord
S2
YES
30 cm
pict. 6
e t
i w
h t
e l
d
s
h
a
s
o t
b
e
e r
q
i u
e r
d
o t
o
r u
IS500
R2
Features and meaning of the symbols shown on the label:
• lighting
appliance
Capable of withstanding the load of motor vehicles with inflatable tyres pumped with
air, maximum weight static or dynamic: 2000Kg.
Fixtures can be utilized in all accessible areas
Pedestrian and drive over, with max. glass temp. of 40°C
20kN static load resistance.
LED 1x2W 220-240V 50/60Hz.
• Do not install in areas where snowplows are used.
RISK GROUP 2
CAUTION:
Possibly
Do not stare at operating lamp. May be harmful to the eye.
fixture outer
casing
electric cables
EMBEDDED INSTALLATION WITHOUT PASSAGE OF VEHICLES
for correct assembly, proceed as follows:
sand and
1) avoid positioning the fixture in areas of subsidence (pict.1) where dirt and stagnant water
gravel draining
can accumulate.
foundation, hosed
Picture 2
until refusal, well
2) make a hole (boring) in the ground with appropriate diameter and deep.
set and tamped
3) square the upper part of the hole by inserting a prefabricated pit. The upper edge of the pit
must be about 2/3 cm higher than the surrounding ground to which it must be connected
with an outer slope for the run-off of water and to avoid the accumulation of dirt.
4) backfill the hole with a mixture of sand and gravel up to a distance of about 20 cm from
the upper edge of the pit. Hose with plenty of water until refusal and tamp the mixture in
fixture outer
such a way as to form a compact and homogenous draining layer.
casing
5) place four bricks with a trowel of mortar on the bottom of the pit in order to form a solid
support base for the outer casing of the fixture which must protrude about 2/3 cm with
electric cables
respect to the edge of the prefabricated pit.
6) backfill the pit around the casing with a mixture of well tamped and set sand
and gravel, arranging the cables for the electrical connection of the fixture.
connection
accessory
4068964
EMBEDDED INSTALLATION WITH PASSAGE OF VEHICLES
concrete block
proceed as in the above points 1-2-3-4.
5) refer to pict.3, prepare lean concrete cement on which to place the block of concrete,
lean concrete
taking care to leave a hole with a diameter of at least 6 cm for drainage. Provide for the
passage of electrical wires.
draining layer
6) insert the outer casing of the fixture into a concrete foundation block, batched at 200
kg of 325 type cement per cubic metre of mixture. The block must have a diameter (or
side) of not less than 30 cm. Line up carefully the upper edge of the outer casing with the
trampling level as per pict. 3.
ELECTRICAL CONNECTION
Important: the electrical connection must be carried out by a skilled electrical. Important: in
the case of damage of the appliance, there may be a reduction in the degree of protection
with consequent infiltration of water and loss of insulation. Therefore, additional protection
should be inserted into the electrical plant against direct contacts (for example a high
sensitivity differential switch). During installation, scrupulously respect the current rules on
electrical systems.
• For the electrical connection use a flexible <HAR> rubber cable cross-section 1x1.5mm
The fixtures are complete with a piece of H07RN-F cable which is pre-connected and sealed.
For a rapid and safe connection with the electric line use the connector 4068964 or an
equivalent system that guarantees at least the IP67 degree.
c
o
m
p
a
n
y
r o
s t i
Feilo Sylvania Europe LTD
Avis Way, Newhaven East Sussex BN9 0ED UK
www.feilosylvania.com
230-240V~ 50/60Hz
for
indoor
and
outdoor
hazardous
optical
radiation
IS13166A
IP
IP
66
67
ground-recessed
fitting.
emitted
from
this
product.
2
.
MI/1849-C - 2
a
ed
ISO
ISO
14001
9001
Environmental
Quality
Management
Management
EM 539002
FM 01687
© Concord Lighting Limited 05.17

Advertisement

loading

Summary of Contents for CONCORD PATHE G/R2-S2

  • Page 1 Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number that recognizes the fixture. MI/1849-C - 2 Feilo Sylvania Europe LTD 14001 9001 Concord Environmental Quality Management Management Avis Way, Newhaven East Sussex BN9 0ED UK www.feilosylvania.com EM 539002 FM 01687 © Concord Lighting Limited 05.17...
  • Page 2 Feilo Sylvania Europe LTD 1400 1 900 1 En vi ronmental Qual ity Ma na ge me nt Ma na ge me nt Avis Way, Newhaven East Sussex BN9 0ED UK EM 539002 FM 01687 © Concord Lighting Limited 05.17 www.feilosylvania.com...

This manual is also suitable for:

Pathe/ground/round2 medium 98lm led 4k4069271