Dimplex fxl fan storage heater range operating instructions fxl18n - 2.6kw / 18kwh storage & 1.5kw boost fxl24n - 3.4kw / 24kwh

Advertisement

FXL(N)
MODELS: FXL18N - 2.6kW / 18kWh STORAGE & 1.5kW BOOST
INSTALLATION
PLEASE READ THIS LEAFLET CAREFULLY AND
RETAIN FOR FURTHER USE. NOTE ALSO THE
INFORMATION GIVEN ON THE HEATER
The Installation must be carried out by trained personnel.
A means for disconnection must be incorporated in the fixed wiring by a double pole switch with a
contact separation of a minimum of 3mm and in accordance with the current IEE Wiring Regulations.
The heater must not be installed immediately below a fixed socket outlet.
The heater is not suitable for connection to a 30A ring circuit.
Do not position the heater under windows where curtains can contact the heater casing.
WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.
This heater meets EN60335 safety requirements. However, any heater type becomes hot in normal
operation. Care must be taken to ensure that prolonged skin contact with the heater does not occur.
WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE
MUST BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.
This appliance is very heavy and must be securely fixed to a wall. DO NOT UNDER ANY
CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING
EXPERT ADVICE.
To maintain stability, it is essential that the heater is placed on a level surface.
This heater must be installed where it is impossible for switches and other controls to be touched by a
person using a bath or shower.
IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the first few
days of operation. ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS,
OR PERSONS WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY
TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.
IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION
SHOWS DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED
BY AN IDENTICAL PART.
FAN STORAGE HEATER RANGE
FXL24N - 3.4kW / 24kWh STORAGE & 1.5kW BOOST
INSTRUCTIONS
IMPORTANT
OPERATING
AND

Advertisement

loading

Summary of Contents for Dimplex FXL18N

  • Page 1 FXL(N) FAN STORAGE HEATER RANGE MODELS: FXL18N - 2.6kW / 18kWh STORAGE & 1.5kW BOOST FXL24N - 3.4kW / 24kWh STORAGE & 1.5kW BOOST INSTALLATION INSTRUCTIONS PLEASE READ THIS LEAFLET CAREFULLY AND RETAIN FOR FURTHER USE. NOTE ALSO THE INFORMATION GIVEN ON THE HEATER The Installation must be carried out by trained personnel.
  • Page 2: Installation Instructions

    The panel can now be lifted clear and set to one side. Remove the packing pieces from the slots on the inner front (3 on the FXL18N and 4 on the FXL24N). Remove the inner front panel by unscrewing the screws along its top and sides.
  • Page 3 Four fixing positions must be chosen for the FXL24N and three for the FXL18N. Mark the positions for the fixing holes - two at the extreme ends and others spaced evenly between them. Remove the bracket from...
  • Page 4: Operating Instructions

    Issue 1 : June 2006 © Glen Dimplex UK Limited. All rights reserved. Material contained in this publication may not be reproduced in whole or part, without prior permission in writing from Glen Dimplex UK Limited. Control Functions Setting the Controls...

This manual is also suitable for:

Fxl24n