Download Print this page

Carrier 48SS018 Performance Data Sheet page 2

Standard-efficiency combination gas heating/ electric cooling units

Advertisement

Date:
Supersedes:
JOB DATA:
BUYER:
UNIT NUMBER:
PERFORMANCE DATA CERTIFIED BY:
ARI 210
ARI 270
Standard one-year warranty.
Five-year Extended Protection Plan for the compressor.
Ten-year non-prorated warranty on heat exchanger.
Units are ''Rated in accordance with ARI Standard No. 270 and
210/240.''
Standard unit as factory assembled is design certified and listed by
UL and CSA.
Low temperature cooling operation standard to 40 F (4 C).
Hermetic compressor with internal linebreak and overload protec-
tion, self lubricating. Scroll compressors on 4 and 5 ton sizes.
Crankcase heater is standard on 024-042 3-phase units. (Not re-
quired on 018, 048 and 060 units.)
Indoor and outdoor coils constructed of aluminum fins mechan-
ically bonded to seamless copper tubes.
48SS units have single-stage cooling and heating.
Foil-faced cleanable insulation.
Sloped non-corrosive condensate drain pan.
Operating Weight
COOLING
Net Total Capacity
Net Sensible Capacity
Compressor Power Input
Outdoor-Air Temperature
Indoor Entering Air db
SEER/EER
FACTORY-INSTALLED OPTIONS
Commercial Grade Base Rail
Dedicated Downshot/Base Rail
FIELD-INSTALLED ACCESSORIES
30% Open Manual Fresh Air Damper
Roof Curb:
8 Height
11 Height
14 Height
One-in. Filter Rack
Crankcase Heater — Single Phase Only
(Required with 0° Low Ambient)
2
PERFORMANCE DATA
lb (unit);
lb (curb)
kW @
°F wb
ELECTRICAL DATA
Power Supply to Unit
Minimum Circuit Amps
ACCESSORIES AND OPTIONS
48SS018, 024, 030, 036, 042, 048 & 060
STANDARD-EFFICIENCY
COMBINATION GAS HEATING/
ELECTRIC COOLING UNITS
LOCATION:
BUYER P.O. #
MODEL NUMBER:
DESCRIPTION
48SS units are standard-efficiency, one-piece gas heating electric cooling units,
pre-wired and pre-charged at the factory.
48SS units are convertible discharge units that can be used for either horizon-
tal or down discharge installations.
FEATURES
Single-point gas connection.
Alternate electrical connections on opposite sides of unit.
Disconnect in accordance with NEC, must be field-supplied and
installed.
Multi-speed, direct drive indoor fan motor.
Weatherized cabinets. Heavy duty phosphated zinc-coated pre-
painted steel. Capable of withstanding 500-hour salt spray.
24-volt control circuit.
Heating controls include a direct spark ignition with flame
rectification. Fan switch, overtemperature switch, and flame roll-
out switch also included.
Induced-draft with hall effect sensor (to prove proper inducer draft
motor operation).
Alumaguard™ coated ''Super-S'' four-pass heat exchanger.
Integrated gas control board provides anti-cycle protection for gas
heat operation.
Base rail standard on all 3-phase units.
CFM
Indoor Fan Motor
Btuh
HEATING
Btuh
Input
°F
Output
°F
AFUE
Volts
Phase
Maximum Overcurrent Protection
FIELD-INSTALLED ACCESSORIES (cont)
Programmable Electronic Thermostat
Thermostat and Subbase
0° Low Ambient
Time Guard II
L.P. Conversion Kit
Controls Upgrade Kit (High and
Low-Pressure Switch)
External Condensate Trap
Natural Gas High-Altitude Kit (2000-5000 ft
Above Sea Level)
48SS
CARRIER #
DATE:
Ext. Static Pressure
Hp
Rpm
%
Hz.
Rev.:
-3SB
in. wg
Bhp
Btuh
Btuh

Advertisement

loading

This manual is also suitable for:

48ss03048ss03648ss02448ss04248ss04848ss060