Introduction
The base stations should be installed at least
1.8 meters above the ground.
To the ceiling a minimum distance of 10
centimeters should be kept.
The optimal installation height for a base is
between 1.8 and 3m depending on the room
height.
We recommend installing all base stations at
the same height.
The minimum distance between stations
depends on the environment and if the base
stations are synchronised.
Bases are slot synchronised (For
example: 2 bases of the same N870
system that are synchronised)
Then a minimum distance of 30
cm
should be maintained
Base are not synchronised
If 2 DECT base stations are not
synchronized their slot-frames will
drift over time. So, depending on
their crystal frequency difference,
one base will transmit in the
receive frame of the other base
station (and vice versa) after some
time. This will block at least one or
more slots on all frequencies and
disturb the signal of the handsets.
This effect is depending on the
distance of the 2 bases. If there is
direct visual contact, a distance of
5 to 10 m should be maintained. If
walls or furniture affect the
signal, a distance of 1 to 2m may
be sufficient.
To supply a hotspot, several base stations
can be mounted side by side.
The distance to supply lines, cable ducts or
metal cabinets should also be at least 10
centimeters.
The approved operating temperature of the
base stations is between + 5 ° and + 45 °
Celsius.
Observer the safety distances and safety
regulations. Observe the regulations
specified in rooms where there is danger of
explosions.
Bases are synchronised,
min 30 cm
Base are not synchronised
distance

Advertisement

loading

Summary of Contents for Gigaset N 70 Series

  • Page 1 FAQ Nx70 - Base stations mounting instructions Introduction The base stations should be installed at least 1.8 meters above the ground. To the ceiling a minimum distance of 10 centimeters should be kept. The optimal installation height for a base is between 1.8 and 3m depending on the room height.
  • Page 2 Do not install the base stations in Suspended ceilings, cup boards or other closed furnishings. The wireless coverage can be significantly reduced, depending on the materials used. The location and alignment of the base stations installed should be identical to the position deemed optimum during the measurement stage.