  • Page 1 Dual Memory Auto-Inflate Blood Pressure Monitor Instruction Guide – UA-774...
  • Page 2: Important Information

    Remove and replace batteries if monitor is not used for more than six months. PRECAUTIONS The UA-774 is designed to be used at home, by those who are eighteen (18) years and older, to monitor blood pressure (systolic and diastolic) and pulse rate. It is not designed for ambulatory use.
  • Page 3 Congratulations on purchasing a state-of-the-art LifeSource blood pressure monitor—one of the most technologically advanced monitors available today. Designed for ease of use and accuracy, this monitor will facilitate your daily blood pressure regimen. Physicians agree that daily self-monitoring of blood...
  • Page 4: Table Of Contents

    MONITOR COMPONENTS ......E-3 HOW UA-774 WORKS ......E-4 BEFORE YOU START .
  • Page 5: What Display Symbols Mean

    WHAT DISPLAY SYMBOLS MEAN Display Condition/Cause Symbol The indicator while measurement is in progress. It blinks while detecting the pulse. An irregular heartbeat or body movement may have occurred. Refer to page E-10 for more information on irregular heartbeats. Previous measurement stored in MEMORY.
  • Page 6: Monitor Components

    MONITOR COMPONENTS AC ADAPTER JACK PULSE DISPLAY SYSTOLIC DISPLAY DIASTOLIC DISPLAY START BUTTONS AIR CONNECTOR AIR SOCKET CUFF TUBE BATTERY COMPARTMENT In Canada (Toll-Free): 1-800-463-5414...
  • Page 7: How Ua-774 Works

    HOW UA-774 WORKS LifeSource™ Blood Pressure Monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillometric method” — a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. Our monitor examines the pulsatile pressure generated by the arterial wall as it expands and contracts against the cuff with each heartbeat.
  • Page 8: Selecting The Correct Cuff Size

    SELECTING THE CORRECT CUFF SIZE Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small will produce a reading that is higher than the correct blood pressure.
  • Page 9: Taking Your Blood Pressure

    TAKING YOUR BLOOD PRESSURE The UA-774 has several modes available to fit your blood pressure monitoring needs. Normal Measurement with Readings Stored in Memory Press the START 1 or START 2 button. Your blood pressure is measured and the reading is stored into memory. Each START button can store up to 30 readings in memory.
  • Page 10 TAKING YOUR BLOOD PRESSURE Now you are ready. Follow these simple steps: Sit comfortably with your left arm resting on a flat surface so that the center of your upper arm is at the same height as your heart. Lay left arm on the table, palm up and thread cuff end through metal loop, smooth side against arm.
  • Page 11 TAKING YOUR BLOOD PRESSURE NOTE: If you wish to stop inflation at any time, press either START button again. NOTE: The maximum cuff pressure is set at 280 mmHg. If it reaches 280 mmHg, the auto exhaust will be triggered and cuff pressure will deflate to 0.
  • Page 12: About Average Reading

    MEASUREMENTS STORED IN MEMORY ABOUT MEMORY The memory function on the UA-774 blood pressure monitor is designed for two people. For each START button, the monitor can store up to 30 readings in memory. To keep track of previous measurements accurately, we recommend that you use the same START button each time you take a blood pressure reading.
  • Page 13: What Is An Irregular Heartbeat

    WHAT IS AN IRREGULAR HEARTBEAT The UA-774 Blood Pressure Monitor provides a blood pressure and pulse rate measurement even when an irregular heartbeat occurs. An irregular heartbeat is defined as a heartbeat that varies by 25% from the average of all heartbeat intervals during the blood pressure measurement.
  • Page 14: Using The Monitor With Ac Adapter

    USING THE MONITOR WITH AC ADAPTER The UA-774 has an AC adapter jack to allow you to supply power from an outlet in your home. We recommend you use only the exclusive AC adapter (Model TB:181) to avoid potential damage to the monitor.
  • Page 15: About Blood Pressure

    ABOUT BLOOD PRESSURE ❤ What Is Blood Pressure? Blood pressure is the force exerted by blood against the walls of the arteries. Systolic pressure occurs when the heart contracts; diastolic pressure occurs when the heart expands. Blood pressure is measured in millimeters of mercury (mmHg).
  • Page 16: What Is Hypertension

    Assessing High Blood Pressure The following standards for assessing high blood pressure (without regard to age) have been established as a guideline. BP Classification Normal Prehypertension Stage 1 Hypertension Stage 2 Hypertension SOURCE: The Seventh Report of the Joint National Committee on Prevention, Evaluation and Treatment of High Blood Pressure.
  • Page 17: Blood Pressure Record

    ABOUT BLOOD PRESSURE ❤ Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pressure readings taken in a doctor’ s office or hospital setting might be elevated as a result of apprehension and anxiety. This response is commonly called “white coat hypertension.”...
  • Page 18 In Canada (Toll-Free): 1-800-463-5414 ❤ E-15...
  • Page 19: Troubleshooting

    ✓ TROUBLESHOOTING Problem Nothing appears in the display, even when the power is turned on. The cuff does not inflate. The unit does not measure. Readings are too high or too low. Other NOTE: If the actions described above do not solve the problem, contact A&D Medical or Auto Control Medical at the numbers listed at the bottom of these pages.
  • Page 20: Specifications

    Model ....UA-774 Type .....Oscillometric Display .
  • Page 21: Contact Information

    This LifeSource blood pressure product is covered by a Lifetime Warranty. See warranty card for details. Visit our web site at www.LifeSourceOnline.com For more information regarding use, care or servicing of your blood pressure monitor, contact: A&D Medical A division of A&D Engineering, Inc. 1555 McCandless Drive...
  • Page 22 CONTACT INFORMATION IMPORTANT! If You Need Assistance with the Set-Up or Operation We Can Help! Please call us FIRST before contacting your retailer at LifeSource Health Line 1-888-726-9966 - Toll Free 1-800-463-5414 - In Canada A specially trained representative will assist you A division of A&D Engineering, Inc.