Download Print this page
Beckett MS601ULQ Quick Start Manual

Beckett MS601ULQ Quick Start Manual

Mini condensate pump

Advertisement

Available languages

Available languages

Quick Links

All Beckett pumps are warranted to the user against defective material and workmanship under normal use, for a period of 1 year from the date of purchase by the original purchaser. All other
Beckett products are warranted to the user against defective material and workmanship for 3 months from the date of purchase. Replacement liability in all events is limited to the replacing or
repairing at Beckett's sole discretion of any part or parts, which are defective in material or workmanship. Proof of purchase is required on all claims in the form of invoice copy, sales ticket, etc.
APPLICATION: Warranty covers only properly installed and maintained units. Warranty is limited to applications pumping fresh water at temperatures of 32°-104°F (0°-40°C), with a pH range of 5
to 9. Beckett Corporation must approve other liquid applications and extreme temperature uses in advance in writing.
ADMINISTRATION: Warranty claims must be made by calling Beckett Corporation, Customer Service Dept., telephone 888-232-5388. Proof of Purchase is required and a $ 5.00 shipping and
handling fee applies to all warranty replacements.
INSTALLATION and/or REMOVAL CHARGES: Warranty does not cover any costs associated with the installation or removal of products subject to warranty claims.
DISPOSITION: Beckett will make a good-faith effort for prompt disposition regarding any item in warranty, which proves to be defective. If products were damaged in transit, please file a claim
with the carrier.
DISCLAIMER: Any oral statements about the product made by the seller, the manufacturer, the representatives or any other parties, do not constitute warranties, should not be relied upon by the
user, and are not part of the contract for sale. Seller's and manufacturer's only obligation and buyer's and user's only remedy, shall be for the manufacturer to either replace and/or repair at the
manufacturer's sole discretion the Beckett product as described above. Neither seller nor the manufacturer shall be liable for any injury, loss or damage, direct, incidental or consequential
(including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss), arising from any cause
whatsoever, no matter whether based upon warranty, contract, negligence or other misuse, and the buyer and user agree that no other remedy shall be available to them. Before using, the buyer
and user shall determine the suitability of the product for the intended use, and assumes all risk and liability whatsoever in connection herewith. The warranty and remedy described in this limited
warranty is an EXCLUSIVE warranty and remedy. IN LIEU of any other warranty or remedy, expressed or implied, which other warranties and remedies are hereby expressly EXCLUDED,
including but not limited to any implied warranty of MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. This Warranty gives buyer and user specific legal rights, and buyer and
user may also have other rights that vary from state to state. Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitation or exclusion may
not apply to you.
Todas las bombas de Beckett están cubiertas por una garantía al usuario contra defectos de materiales y fabricación durante doce (12) meses a partir de la fecha de compra, siempre y cuando se
le haya dado uso normal. Todos los demás productos de Beckett están cubiertos por una garantía al usuario contra defectos de materiales y manufactura durante tres (3) meses a partir de la
fecha de compra. En estos casos, la responsabilidad de reemplazo se limita a la sustitución y / o reparación a discreción exclusiva de Beckett de la(s) pieza(s), que tengan defectos de materiales
o manufactura. Para efectuar reclamos se requiere una pruebe de la adquisición, tal como la factura o en su defecto la nota de entrega.
APLICACIÓN: la garantía sólo cubre las unidades instaladas y mantenidas correctamente. La garantía se limita al bombeo de agua fresca en temperaturas de 32° F a 104° F (0° C a 40° C) y
con una escala de pH de 5 a 9. La Corporación Beckett debe aprobar por escrito el uso de otros líquidos y la operación bajo temperaturas extremas.
ADMINISTRACIÓN: Para cualquier reclamo de garantías, es necesario marcar a Beckett Corporation, al Departamento de Servicio al Cliente, al 888-232-5388. Es necesaria una prueba de
compra y se cobrarán $5.00 US dlls por manejo y envío de piezas repuestas por garantía.
CARGOS POR INSTALACIÓN Y / O RETIRO: La garantía no cubre costos asociados con la instalación o el retiro de producto sujeto a reclamos de garantía.
DISPOSICIÓN: La Corporación Beckett hará esfuerzo en buena fe de solucionar prontamente su reclamo por los artículos bajo garantía que resulten defectuosos. Si los productos fueron
dañados en tránsito, debe presentar su reclamo a la compañía transportadora.
LIMITACIÓN DE RESPONSABILIDAD: El usuario no debe confiar en declaraciones verbales sobre el producto hechas por el vendedor, el fabricante o por cualquier otra persona, porque éstos
no constituyen garantías ni forman parte del contrato de venta. La única obligación del fabricante con respecto al comprador y / o usuario es reemplazar y / o reparar el producto Beckett, a su
exclusiva discreción, como se ha indicado anteriormente. Ni el vendedor ni el fabricante serán responsables de ninguna lesión, perdida o daño, directo, incidental o consecuente (incluyendo, pero
no limitado a daños incidentales o consecuentes por pérdidas de ganancias, ventas, daños personales o daños a propiedades o cualquier otra pérdida incidental o consecuente) que se deban a
cualquier causa, tanto si se basan en garantías como en contratos, negligencias u otras malas aplicaciones, y el comprador y / o usuario aceptan que no tendrán a su disposición ningún otro
recurso. Antes de utilizarlo, el comprador y / o usuario deberán determinar si el producto es adecuado para la aplicación a la que vaya a destinarse y asumen todos los riesgos y las
responsabilidades relacionadas con sus utilizaciones. La garantía y los recursos escritos en este parágrafo se consideran obligaciones exclusivas y en lugar de cualquier otra garantía expresa o
implícita. Se excluyen de modo expreso todas las otras garantías incluyendo sin limitación cualquier garantía implscita de COMERCIALIDAD O CONVENIENCIA PARA CUALQUIER
PARTICULAR. Esta garantía da al adquiriente y / o al usuario derechos legales específicos y ambos pueden tener también otros derechos que varían de un estado a otro. Algunos no permiten la
exclusión o limitación de los daños y perjuicios incidentales o consecuentes, por lo tanto puede ser que la anterior limitación de la responsabilidad no sea aplicable en su caso.
LIMITED WARRANTY
GARANTÍA LIMITADA
BECKETT CORPORATION
3321 E. Princess Ann Rd.
Norfolk, Va. 23502
www.beckettus.com
Toll Free:
888-232-5388
© 2021 BECKETT CORPORATION All Rights Reserved
Models: MS601ULQ & MS602ULCQ
This MS60 Mini Condensate Pump is designed to be installed within Wall, Ceiling Suspended and Floor Mounted
Mini-Split and Chilled Water Fan coil Air Conditioning Units with a maximum rating of 36,000 BTU (3 tons).
This unit is rated for 50% duty cycle. The Pump consists of two parts: Pump Unit and Sump/Detection Unit.
MS601ULQ
MS602ULCQ
Parts included are as shown:
Pump Unit
Mounting Pad
MAXIMUM SUCTION: 4.0 FEET
The Pump Unit must be installed, preferably in the vertical position, either within the air handling unit, in an adjacent gutter or in the false ceiling above the unit.
A space must be left around the Pump Unit in
order to provide adequate cooling during
prolonged operating periods. Do not insulate
the Pump Unit.
* If the mounting pad
Flow
will not completely
direction
seat into the pump
arrow on
slot use a small
pump label
amount of water.
Pump Power Supply
Connect Pump Live, Neutral and Earth terminals to the air handling unit's power supply or to the main's supply by means of
wiring which complies with local National Standards. We suggest use of an interconnecting power cable (HO5 WF 3G 0.75
mm2), which must be fastened securely, to avoid inadvertent disconnection during installation and later servicing. This
connection should be equipped with an electrical isolation device (2A Fused Spur – not included) to Live or Neutral.
Pump Safety Function
IMPORTANT: The Pump is equipped with a normally closed (NC) high
water safety contact with a maximum rating of 3A/250V.
The connecting cable must be chosen accordingly.
This contact may be used to switch off the refrigeration system where
there is a risk of condensate overflow (after thorough verification by the
installer of the customer's specific application and the resultant electric
wiring diagram). This contact may also be used to connect an alarm.
The Detection Unit can be connected in 3 ways:
(But unit must always be mounted level)
Directly inside the
Directly at the condensate
At the Output from the
condensate drain tray.
drain tray outlet.
condensate evacuation tube.
Please ensure that your installation is set up accordingly by the direction of flow (on pump label).
Initial Operational Test:
First clean the condensate tray of any debris leftover from manufacture of unpacking of the air handling unit.
Pour water into the condensate collection tray.
Check that the Pump unit starts and then stops as the water level decreases.
Check Safety function by continuing to pour water until the safety switch triggers (cutting off the compressor, generating an audible or visual alarm, etc.).
Cleaning and Servicing:
The Sump/Detection Unit (and the filter) must be cleaned and serviced at regular intervals in accordance with the level of pollution existing within the Pump operating environment.
Remove the Sump/Detection Unit cover.
Remove the filter.
Clean the Sump/Detection Unit body, magnetic float and filter with solution of 95% water and 5% bleach.
Reinstall filter and float making sure ring magnet is on top.
Replace the filter and Sump/Detection Unit cover.
Test Pump Operation as explained in "Initial Operational Test", above.
Ensure that the Vent Tube does not contain water. Do not use a longer tube than the one supplied.
Failure to follow these Instructions can lead to poor results, (tank overflow, high noise level, abnormal overheating, etc.) which are both inconvenient for the end user and costly for the installer!
MINI CONDENSATE PUMP
Pump Unit Supplied with:
A self-resetting thermal protector
An Earth Ground Connection
Do not pump any liquids other than water (Max temp 104
Do not use this pump in explosive areas.
Do not run dry.
Sump/Detection Unit
Do not handle unit with wet hands or while standing in water.
Do not connect to any voltage other than that shown on
nameplate.
Always disconnect this unit from its electrical supply before
servicing.
Connect safety switch for proper operation.
For Indoor use only.
1/5" (5mm) I.D. PVC Tubing
The Pump must have an electricity supply that is independent to that
5/8" I.D. Rubber Tube
of the air conditioner to ensure that it continues to operate if the
refrigerating appliance breaks down.
4mm Clear Plastic Tube
2pcs ties,2.5*100mm
NOTE: Before installation, thoroughly rinse the coil and the
condensate collection tray to get rid of any foreign bodies and
4pcs ties,3.5*290mm
metal particles.
INSTALLATION
Venting Installation
Connect the 4mm plastic Vent Tube to the upper outlet of the Sump/Detection Unit.
The free end of air Vent Tube must be secured as high as possible and must remain
free of kinks. The Vent Tube allows the air to be bled from the Detection Unit. You are
advised to use the 4mm tube supplied. Its length allows the upper level of the tube to
be slightly above the maximum level of the Condensate Drain Tray. In the event of an
alarm or defect, this avoids overspill.
MAINTENANCE
Ring magnet is on top.
A = SAFETY .83"±.08" (21mm±2mm)
B = START-UP .67"±.08" (17mm±2mm)
C = PUMP SHUTDOWN .43"±.08" (11mm±2mm)
92336_Rev 02
WARNING!
0
F)
IMPORTANT
* If the pump
discharge tube is
installed below the
drain pan with no air
gap the pump will
have to re-prime
itself each time
which causes loud
operation and
shorter pump life.
Condensate Discharge
Connect the Condensate Pump
discharge outlet to the drain (or other
as may suit the installation) via ¼"
I.D. plastic tubing (not included).
Condensate Detection
The suction side of the Pump (linking
the outlet of the Detection Unit to the
Pump Intake) must be connected to
the outlet port on the Detection Unit
with a ¼" I.D. plastic tubing.

Advertisement

loading

Summary of Contents for Beckett MS601ULQ

  • Page 1 Pump Unit Supplied with: repairing at Beckett’s sole discretion of any part or parts, which are defective in material or workmanship. Proof of purchase is required on all claims in the form of invoice copy, sales ticket, etc. Mini-Split and Chilled Water Fan coil Air Conditioning Units with a maximum rating of 36,000 BTU (3 tons).
  • Page 2 MINI BOMBA DE CONDENSADOS Modelos: MS601ULQ & MS602ULCQ ELECTRICAL CONNECTION Esta Bomba Condensada Mini MS60 es diseñada para ser instalado dentro de la Pared, Techo Suspendido y Suelo Minihendidura Montada La Unidad de la bomba esta equipada: y Abanico de Echar agua Enfriado enrollan Unidades de Aire Acondicionado con una posición máxima de 36,000 Unidad térmica británica (3 •...

This manual is also suitable for:

Ms602ulcq