Combination Ports And Failover - Extreme Networks Summit X450a-24tDC Hardware Installation Manual

Extremexos summit family switches summit x150 series summit x250e series summit x350 series summit x450 series summit x450a series summit x450e series
Hide thumbs Also See for Summit X450a-24tDC:
Table of Contents

Advertisement

Summit Family Switches
Table 4
shows the models in each Summit series in the Summit family of switches.
Table 4: Summit Switches
Summit X150
Series Switches
Summit
X150-24t
Summit
X150-24p
Summit
X150-48t
Refer to the following sections for specific hardware details about each series:
Summit X150 Series Switches on page 17
Summit X250e Series Switches on page 22
Summit X350 Series Switches on page 34
Summit X450 Series, X450a Series, and X450e Series Switches on page 38
NOTE
See the ExtremeXOS 12.0 Concepts Guide and the ExtremeXOS 12.0 Command Reference Guide for feature-specific
information about the Summit switches and for information regarding switch configuration.

Combination Ports and Failover

Summit family switches provide two or four uplink ports implemented as combination ports that pair a
copper port using RJ-45 connectors with an optical port using LC connectors. The copper port operates
as an autonegotiating 10/100/1000BASE-T port. The optical port allows Gigabit Ethernet uplink
connections through Extreme Networks small form factor pluggable (SFP) interface modules. See the
individual switch descriptions for the port numbers of the combination ports on each switch model.
Summit family switches support an automatic failover from an active fiber port to a copper backup or
from an active copper port to a fiber port. If one of the uplink connections fails, the Summit uplink
connection automatically fails over to the second connection. To set up a redundant link on one of the
combination ports, connect the active 1000BASE-T and fiber links to both the RJ-45 and SFP interfaces of
that port.
Gigabit Ethernet uplink redundancy on the Summit family switches follows these rules:
With both the SFP and 1000BASE-T interfaces connected on a combination port, only one interface
can be activated. The other is inactive.
If only one interface is connected, the switch activates the connected interface.
16
Summit X250e
Summit X350
Series Switches
Series Switches
Summit
Summit
X250e-24t
X350-24t
Summit
Summit
X250e-24tDC
X350-48t
Summit
X250e-24p
Summit
X250e-24x
Summit
X250e-24xDC
Summit
X250e-48t
Summit
X250e-48p
Summit X450
Summit X450a
Series Switches
Series Switches
Summit
Summit
X450-24t
X450a-24t
Summit
Summit
X450-24x
X450a-24tDC
Summit
X450a-24x
Summit
X450a-24xDC
Summit
X450a-48t
Summit
X450a-48tDC
Summit Family Switches Hardware Installation Guide
Summit X450e
Series Switches
Summit
X450e-24p
Summit
X450e-48p

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents