Download Print this page

Advertisement

Quick Links

This guide is intended to provide basic information required in order to set-up a drive to run a motor.
Please refer to the Unidrive M300 User Guide which is available to download from
www.controltechniques.com/userguides.
1
Safety information
This guide does not include safety information. Incorrect installation or operation of the
drive, could cause personnel injury or equipment damage. For essential safety
information, please refer to the Unidrive M300 User Guide or the safety booklet supplied
with the drive.
WARNING
2
Product information
2.1
Ratings
Input
phases
Model
current
ph
01100017
1
01100024
1
01200017
1
01200024
1
01200033
1
01200042
1
02100042
1
02100056
1
02200024
1 / 3
5.3/4.1
02200033
1 / 3
8.3/6.7
02200042
1 / 3
10.4/7.5
02200056
1 / 3
14.9/11.3
02200075
1 / 3
18.1/13.5
02400013
3
02400018
3
02400023
3
02400032
3
02400041
3
03200100
1 / 3
23.9/17.7
03400056
3
03400073
3
03400094
3
04200133
1 / 3
04200176
3
04400135
3
04400170
3
The nominal cable sizes shown in the table above, are provided as a guide only. Ensure
NOTE
that the cables used conform to the local wiring regulations.
Unidrive M300 Quick Start Guide
Issue Number: 1
Unidrive M300
Quick Start Guide
Max input
fuse rating
Max.
cont
input
1 Ph
3 Ph
A
A
A
10
16
6
6
10
16
18.8
20
24
25
6
6
10
10
16
10
20
15
20
15
2.4
6
2.9
6
3.5
6
5.1
6
6.2
10
25
20
8.7
10
12.2
16
14.8
16
25
20
25
20
25
Nominal cable size
European
USA
Input
Output
Input
2
2
AWG
mm
mm
1
1
16
1
1
14
1
1
16
1
1
16
1
1
16
1
1
16
2.5
1
12
4
1
10
1
1
16
1
1
16
1
1
16
2.5/1.5
1
12/14
2.5
1
12
1
1
16
1
1
16
1
1
16
1
1
16
1
1
16
4
1.5
10/12
1
1
14
1.5
1
12
2.5
1.5
12
4/2.5
2.5
10
4
2.5
10
2.5
2.5
10
4
2.5
10
Output current
Max.
cont
Nominal
Output
output
power
current
AWG
A
kW
16
1.7
0.25
16
2.4
0.37
16
1.7
0.25
16
2.4
0.37
16
3.3
0.55
16
4.2
0.75
16
4.2
0.75
16
5.6
1.1
16
2.4
0.37
16
3.3
0.55
16
4.2
0.75
16
5.6
1.1
16
7.5
1.5
16
1.3
0.37
16
1.8
0.55
16
2.3
0.75
16
3.2
1.1
16
4.1
1.5
14
10
2.2
16
5.6
2.2
16
7.3
3
14
9.4
4
12
13.3
3
12
17.6
4
12
13.5
5.5
12
17
7.5
Motor
power
hp
0.33
0.5
0.33
0.5
0.75
1
1
1.5
0.5
0.75
1
1.5
2
0.5
0.75
1
1.5
2
3
3
3
5
3
5
7.5
10
1

Advertisement

loading

Summary of Contents for Control Techniques 01100017

  • Page 1 Max. phases input cont Nominal Motor Model 1 Ph 3 Ph Input Output Input Output current output power power current 01100017 0.25 0.33 01100024 0.37 01200017 0.25 0.33 01200024 0.37 01200033 0.55 0.75 01200042 0.75 02100042 18.8 0.75 02100056...
  • Page 2 Figure 2-1 Rating label and product identification Derivative Electrical Specifications M300 - 00073 Product line: Drive Format : A – AC in AC out Frame size: Voltage rating Current Rating : 1 - 100 V (100 - 120 ± 10 %) Heavy Duty current rating x10 2 - 200 V (200 - 240 ±...
  • Page 3 Electrical installation Figure 4-1 below shows an overlay of the electrical connections / terminals available on the drive. For further information regarding terminal specification, cable sizes etc., refer to the Unidrive M300 User Guide. Figure 4-1 M300 Overlay of electrical connections Digital I/O Analog I/O 24 V user...
  • Page 4 Running the motor This section takes a new user through all the essential steps to running a motor for the first time. Section 4 provides the minimum connections required to connect and run a motor. The most commonly used parameters are shown on the terminal cover of the drive. Action Detail Ensure:...

This manual is also suitable for:

Unidrive m3000110002401200017012000240120003301200042 ... Show all