Configuring Cable
Diagnostics
The Cable Diagnostics Summary Page contains the following fields:
Ports — Specifies the port to which the cable is connected.
Test Result — Displays the cable test results. Possible values are:
No Cable — Indicates a cable is not connected, or the cable is
connected on only one side, or the cable is shorter than 1 meter.
Short Cable — Indicates that a short has occurred in the cable.
OK — Indicates that the cable passed the test.
Cable Fault Distance — Indicates the distance from the port where
the cable error occurred, in meters.
Last Update — Indicates the last time the port was tested.
2 Click Apply. The test results are displayed.
The Diagnostics Page contains fields for performing tests on copper
cables. Cable testing provides information about where errors occurred in
the cable, the last time a cable test was performed, and the type of cable
error, which occurred. The tests use Time Domain Reflectometry (TDR)
technology to test the quality and characteristics of a copper cable
attached to a port.
When performing cable tests consider the following:
During the tests, ports are in the down state.
The minimum cable length resolution is one meter, so if the cable is
shorter than 1 meter the test will display "no cable".
An open cable or a 2-pair copper cable will display a cable fault
distance of 0.
The maximum cable length is 120 meters.