TROUBLESHOOTING

Check the following points before calling your local authorised Service Centre.
PROBLEMS
The appliance is operating in
dehumidifying mode, but the
humidity does not decrease.
The appliance does not
work for 3 minutes after
start-up.
is displayed
is displayed
"E2"/"E3" is displayed
Symbol "PUMP" is
displayed
CAUSE
The filter is blocked.
The temperature or humidity
in the room are too low.
The room is too big for the
dehumidifying power of the
appliance.
Too many sources of humidity
in the room (pots of boiling
water, etc.).
The humidy set point is too
high.
The safety device has tripped.
The tank is missing.
The tank is full.
The tank is incorrectly
positioned.
The temperature in the room is
very low.
One of the sensors on the
appliance is faulty.
The condensation discharge
pump is missing.
9
SOLUTION
Clean the filter.
In certain conditions, it is nor-
mal for the appliance not to
dehumidify (in certain cases,
it is recommended to heat the
environment).
Decrease the humidity set
point.
Wait for 3 minutes to pass.
Replace the tank.
Empty the tank.
Position the tank correctly.
Increase room temperature.
Call the Service Centre.
Check the hose is correctly
positioned.
Disconnect and reconnect the
plug.