GENERAL
4-Pair LPU
This job aid provides information for the installation, function, and operational use of
the ADTRAN
to provide power for the Total Access
P/N: 1181501L2
Line Access Multiplexer (DSLAM).
CLEI: SIPQ0CVF_ _
DESCRIPTION
LPU
Each ADTRAN LPU provides up to 100 watts of power to an associated DSLAM on
1181501L2
POWER
a one-to-one basis. The LPU can reside either in a Central Office (CO) or be installed
in a remote facility in close proximity to the associated DSLAM. The LPU provides
UNDER VOLTAGE
±145 VDC power and can span distances up to 60 kft (approximately 11 miles).
GROUND FAULT
OVERLOAD
Each LPU occupies any two adjacent slots in a 3192 shelf. Slots not occupied by an
LPU can house standard channel cards. Total slot population is limited by the
UNDER CURRENT
maximum input current of the 3192 shelf.
The LPU receives –48 VDC at a maximum of 2.6 amps from the chassis backplane
and outputs to four Tip and Ring power pairs. Voltage potential per pair is Tip +145
VDC and Ring –145 VDC (290 VDC combined).
The total power wiring pair requirement is based on transmission distance to the
remote location.
FUSES
Power input to the LPU is fused at 4.0 amps; Tip and Ring power output is fused at
1.5 amps each. Fuses are not replaceable.
LED INDICATION
Five front panel LEDs provide status for the LPU. The
normal condition is on. All other LEDs are red; their normal condition is off. LEDs
are as follows:
LED
POWER
UNDER VOLTAGE
GROUND FAULT
OVERLOAD
UNDER CURRENT
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
3192 4-Pair Line Power Unit
®
3192 Line Power Unit (LPU). The LPU (P/N 1181501L2) is designed
1124/1148 Line Powered Digital Subscriber
®
Status Description
On
LPU receiving –48 VDC
Off
LPU not receiving power or supply fuse failed
On
< 115 VDC per T or R (< 230 VDC per T/R pair)
Off
Voltage normal: ±145 V per T/R (± 5%)
On
Ground fault detected
Off
No ground fault
On
> 0.4 amps at 290 VDC
Off
No overload
On
< 0.04 amps
Off
Current normal
INSTALLATION
After unpacking the unit, inspect it for damage. If damage is noted, file a claim with
the carrier, and then contact ADTRAN. For more information, refer to the warranty.
The LPU installs in any two adjacent slots in a 3192 shelf.
WARNING: Adhere to static discharge precautions when handling circuit cards.
To insert the LPU, perform the following steps:
1. If present, remove the blank panel from the appropriate module slot of the
2. Pull the ejector latch, located on the lower right-hand side of the LPU front panel,
3. Hold the LPU by the front panel while supporting the bottom edge of the module
4. Align the LPU card edges to fit in the lower and upper guide grooves for the
5. Slide the LPU into the module slot. Simultaneous thumb pressure at the top
6. Secure the LPU in place by pushing in on the ejector latch.
Upon installation, the LPU initiates a self-test. Once the power up self-test is
completed, the front panel LEDs reflect the true state of the hardware.
LED is green; its
POWER
chassis.
from its closed position.
with the ejector latch opened to engage the chassis edge.
access module slot.
(above the
LED) and at the bottom (below the electrostatic caution
POWER
symbol) of the front panel ensures that the LPU is firmly positioned against the
backplane of the chassis.
61181501L2-22C
0510

Advertisement

loading

Summary of Contents for ADTRAN 3192

  • Page 1 ±145 VDC power and can span distances up to 60 kft (approximately 11 miles). GROUND FAULT OVERLOAD Each LPU occupies any two adjacent slots in a 3192 shelf. Slots not occupied by an LPU can house standard channel cards. Total slot population is limited by the UNDER CURRENT maximum input current of the 3192 shelf.
  • Page 2 NOTE: Connect only those output pairs required to meet power requirements of the Total Access 1124 DSLAM based on the transmission distance. Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found online at www.adtran.com/warranty.