Controls, Indicators & Connectors; Front Panel Controls & Indicators - Crown Macro-Tech MA-1200 Reference Manual

Crown macro-tech ma-1200: reference guide
Hide thumbs Also See for Macro-Tech MA-1200:
Table of Contents

Advertisement

2 Controls, Indicators &
Connectors
A. Dust Filters
The dust filters remove large particles from the air
drawn in by the cooling fan. Check the filters regularly
to prevent clogging. The filter elements can be easily
removed for cleaning by gently pulling them away from
the front panel (see Sections 3.2 and 4.5).
B. Level Controls
The output level for each channel is set with these con-
venient level controls mounted on the front panel. Each
level control has 31 detents for precise adjustment (see
Section 4.4). A security option is available to prevent
tampering (see Section 8.3).
C. Signal/IOC Indicators
These green multifunction indicators show signal pres-
ence and distortion for each channel. As signal pres-
ence indicators, they flash synchronously with the
output audio signals to show their presence. As IOC
(Input/Output Comparator) indicators, they flash
brightly with a 0.1 second hold delay if there is a differ-
ence of 0.05% or more between the input and output
signal waveforms. This provides proof of distortion-free
performance . Another IOC function is to indicate input
overload. If an input signal is too large, the indicator for
the affected channel flashes brightly with a 0.5 second
hold delay to show clipping distortion. Note: The Chan-
nel 2 IOC indicator stays on in Parallel-Mono mode (see
Section 4.2).
D. ODEP Indicators
During normal operation of the ODEP (Output Device
Page 8
Fig. 2.1 Front Panel Controls & Indicators
Emulation Protection) circuitry, these amber indicators
glow brightly to show the presence of reserve thermal-
dynamic energy. They dim proportionally as energy re-
serves decrease. In the rare event that energy reserves
are depleted, the indicators turn off and ODEP propor-
tionally limits output drive so the amplifier can safely
continue operating even under severe conditions.
These indicators can also help identify more unusual
operating conditions (see Section 4.2).
E. Enable Indicator
This indicator lights when the amplifier has been "en-
abled" or turned on, and AC power is available (see
Section 4.2).
F. Enable Switch
This push button is used to turn the amplifier on and off.
When turned on, the output is muted for approximately
four seconds to protect your system from start-up tran-
sients. (This delay can be changed. Contact Crown's
Technical Support Group for details.)
G. Power Cord
The power cord has an appropriate plug for the re-
quired voltage. 120 VAC, 60 Hz North American Macro-
Tech 600s and 1200s have 14 AWG line cords and
NEMA 5-15P plugs. Macro-Tech 2400s have 12 AWG
line cords and NEMA 5-20P plugs. International units
are shipped with an appropriate line cord and plug. See
Section 7 for AC power usage.
H. Stereo/Mono Switch
The three operating modes of a Macro-Tech amplifier
Macro-Tech 600/1200/2400 Power Amplifiers
Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents