Installation Step 6
Install the Multi-Function
Door Control Panel
• Locate the door control within sight of the door at a
minimum height of 5 feet where small children
cannot reach, and away from all moving parts of the
door and door hardware.
The multi-function door control panel is typically attached
directly to the wall (Figure 1). For pre-wired installtions (as
in new home construction) it can be mounted to a
standard single gang box (Figure 2).
• Strip 1/4" of insulation from one end of the bell wire;
connect the wire to the two screw terminals on the back
of the door control panel as follows: white to 2 and
white/red to 1. (NOTE: If "Lock" and "Light" buttons
do not function after completing installation, reverse
the connections.)
• For standard wall mount, fasten the door control panel
securely with 6ABx1-1/4" self-tapping screws. Run the
bell wire up the wall and across the ceiling to the opener.
Use insulated staples to secure the wire in several
places. Be careful not to pierce the wire with a staple,
thereby resulting in a short.
• For pre-wired installations, mount the door control to the
gang box with the 6-32x1" machine screws provided.
• Connect the bell wire to the opener terminal screws as
follows: white to 2 and white/red to 1.
• Remember to affix the User Safety Instruction label
to the wall near the door control, and the
Maintenance Instruction Label in a prominent
location on the inside of the garage door.
If the label adhesive will not adhere to your garage wall
surface (or becomes loose with time) use tacks to secure
the label alongside the door control.
Page 32 explains how to operate the opener using the
door controls and the Lock and Light features available on
the Multi-Function Door Control Panel.
Hardware Shown Actual Size
6ABx1-1/2" Screw
Lighted Door Control Button
6ABx1" Screw
Multi-Function Door Control Panel
1
2
RED
WHITE
Multi-Function
Door Control Panel
Terminal Screws
Insulated Staples
Dry Wall Anchors
2-Conductor
Bell Wire
Light Button
Lock
Button
Door Control
Push Bar
Figure 1
Standard Installation
18
WARNING
DO NOT CONNECT TO LIVE ELECTRICAL WIRING.
CONNECT ONLY TO 24 VOLT LOW VOLTAGE
WIRES. CONNECTION TO LIVE WIRES OR HIGHER
VOLTAGE MAY CAUSE SERIOUS INJURY FROM
SHOCK, BURN OR ELECTROCUTION.
Children operating or playing with a garage
door opener can injure themselves or others.
CAUTION
The garage door could close and cause
serious injury or death.
Install the Door Control (or any additional push
buttons) out of the reach of children and away
from all moving parts of the door and door
hardware, but where the garage door is visible.
Do not allow children to operate the push
button(s) or the remote control transmitter(s).
A moving garage door could injure someone
under it. Activate the opener only when the
door is properly adjusted, you can see it
clearly, and there are no obstructions to door
travel.
Do NOT connect the power and operate the
opener at this time. The trolley will travel to the
full open position but will not return to the
close position until the sensor beam is
connected and properly aligned. See Safety
Reversing Sensor Instructions beginning on
page 21.
Figure 2
Alternate Installation
Terminal Screws
Right Panel
of Opener
24 Volt
2-Conductor
Bell Wire
Opener
1
2
3
9
1
9
1
7
7
3
3
5
5
KG
KG
Antenna
W