Water Connection: APT Brewers are supplied with 1/4” flared water inlet fittings and flare nuts. Use a 1/4” diameter copper tubing to connect brewer to a cold water supply line with a minimum water pressure of 20 p.s.i. HIGHLY RECOMMENDED: An external water supply shut-off valve near the brewer and a water purifier filter for better tasting fresh brewed tea and coffee beverage.
Thermostat Adjustments Thermostat is factory set for proper operating temperature of 197°F to 203°F with the adjustment Knob set to the maximum clockwise position. If field adjustments are needed proceed as follows: To DECREASE temperature, turn the control shaft slightly to the left COUNTERCLOCKWISE. To INCREASE temperature, proceed as follows: With the control knob ALREADY TURNED TO ITS MAXIMUM CLOCKWISE POSITION, locate the small, slotted ADJUSTMENT SCREW inside the hollow shaft.
SCREW 1/4-20 x 5/8 S.S. TANK TOP ASSEMBLY WATER TANK SUB-ASSEMBLY HEATER ELEMENT 1750W (120V) HEATER ELEMENT 3500W (240V) HEATER ELEMENT 2400W (220V) EXPORT Ni53a.doc CECILWARE PART NO HI-LIMIT K642Q ELBOW 90° SILICONE TUBING 1/2" I.D. x 14" LONG L592A L593A TUBING 1/4"...
Page 7
DISPENSE VALVE HI-LIMIT TERMINAL BLOCK WATER INLET VALVE WATER LEVEL PROBES CECILWARE CORPORATION ELECTRICAL DIAGRAM, APT100G, APT100G/WT THERMOSTAT LEVEL CONTROL DISPENSE VALVE HEATER SW...