Figure 3-15. Alarm Relay Configuration Menu; Table 3-5. Types Of Alarms In Alarm Relay Configuration - ADTRAN MX2800 M13 User Manual

Adtran network adapter user manual mx2800 m13
Table of Contents

Advertisement

Section 3, Configuration
Table 3-5
describes the alarm conditions found in the

Table 3-5. Types of Alarms in Alarm Relay Configuration

Alarm
DS3 Alarms
RAI
AIS
LOS
LOF
XCV
TLOS
DS2 Alarms
RAI
AIS
3-34

Figure 3-15. Alarm Relay Configuration Menu

Level
Description
Critical
The unit is receiving an RAI (yellow) alarm from the network. This
alarm is a signal sent back toward the source of a failed transmit circuit.
The X-bits (X1 and X2) are set to zero.
Critical
The unit is receiving an AIS (blue) alarm from the network. This alarm
occurs when consecutive 1010s are received in the information bits,
indicating the fault lies at or upstream from the transmitting source.
Critical
The unit has lost the network Rx signal.
Critical
The unit detects a framing loss from the network.
Noncritical
The controller card is receiving code violations in excess of the user
specified threshold. Refer to
Critical
The controller card transmitter has failed.
Noncritical
The unit is receiving an RAI (yellow) alarm from the network across a
DS2. This alarm is a signal sent back toward the source of a failed trans-
mit circuit. The X-bits (X1 and X2) are set to zero.
Noncritical
The unit is receiving unframed all ones across a DS2.
MX2800 M13 Multiplexer User Manual
Alarm Relay Configuration
XCV Threshold
menu.
on page 3-15.
61200290L1-1G