Acceptance Test Procedure; Introduction; Verifying The Installed Options - ADTRAN MX2800 M13 User Manual

Adtran network adapter user manual mx2800 m13
Table of Contents

Advertisement

1.

INTRODUCTION

This appendix describes the procedures to be used in performing acceptance testing of ADTRAN's Total
Access MX2800 M13 Multiplexer. It is assumed that the MX2800 has already been installed, powered-up,
equipped and cabled to the DSX-1 and DSX-3 or connecting equipment according to the specifications
described in
Section 2, Installation and Operation
The MX2800 is an M13 multiplexer used to consolidate 28 DS1 circuits on to a DS3. The unit can be
equipped in various ways. In general, this section addresses the following areas:
• Verifying the options installed on the unit
• Configuring the unit for test
• Testing all DS1 and DS3 circuits to make sure that each circuit passes error free data
• Verifying that alarms are generated and passed to external alarm systems
• Testing the system power supply and controller card redundancy
• Restoring the unit to the desired configuration
• Configuring the unit for customer traffic
• Completing the Acceptance Test Procedures (ATP) Checklist
2.

VERIFYING THE INSTALLED OPTIONS

The installed configuration determines the level of redundancy the unit supports. There may be one or two
Power Supply Units (PSUs) and Controller Card Units (CCUs) present. A single PSU and CCU are
required for operation without redundancy. Equipping the shelf with two of each provides full redundancy.
The PSUs are the smaller modules on the left side. The CCUs are the larger modules toward the center and
right of the shelf. Visually note which cards are installed in the chassis under test.
61200290L1-1G
A
A, A
PPENDIX
CCEPTANCE
Appendix A

Acceptance Test Procedure

and local operating company procedures.
T
P
EST
ROCEDURE
A-1