DS3 MODULE
NOTE: The Total Access 4303 DS3 Module requires SCU firmware of C.02 or greater.
Insert the module into the desired slot (1 through 4 only) (hot insertion permissible).
The module connects to connectors on the backplane. Connecting the BNC Module
(P/N 1200323L1) to the connectors provides two dual BNC connectors (see the BNC
Module Job Aid, 61200323L1-22).
The Total Access
is no need to reboot.
Once installed, use the terminal menus to configure and control the module (see the
SCU Job Aid, 61200334L1-22).
Use the arrow keys on the VT100 terminal keyboard to move to the Modules menu;
press E
C A U T I O N
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
TOTAL ACCESS 4303 DS3 MODULE
Off
Blown fuse or no power supplied to the shelf
Green
Online
Flashing Green Offline
Amber
Self-test in progress
Red
Module failure
Flashing Red
Self-test failure
Green
Active DS3 Module
Flashing Green Standby DS3 - redundancy enabled
Flashing Red
Standby DS3 - cannot automatically become the active
DS3 while the current active DS3 is installed
Off
DS3/DS1 not configured for use
Green
DS3/DS1 signal present and synchronized; channel is
configured for use
Amber
DS3/DS1 test in progress (includes port self-test)
Red
DS3/DS1 alarm present
Flashing Red
DS3/DS1 error
4303 SCU automatically detects the presence of the module. There
®
in the Menu column of the appropriate module.
NTER
The Total Access 4303 DS3 module is NRTL listed to the applicable UL standards.
The Total Access DS3 is to be installed in a restricted access location and in a Type
"B" or "E" enclosure only.
This device complies with Part 15 of the FCC rules. Operation is subject to the fol-
lowing two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Changes or modifications not expressly approved by ADTRAN could void the user's
authority to operate this equipment.
ADTRAN will replace or repair this product within the warranty period if it does not
meet its published specifications or fails while in service. Warranty information can
be found at www.adtran.com/warranty. U.S. and Canada customer Faxback:
877-457-5007, Document 414.
JOB
A
ID

Advertisement

loading

Summary of Contents for ADTRAN DS3

  • Page 1 DS3/DS1 error The Total Access 4303 DS3 module is NRTL listed to the applicable UL standards. The Total Access DS3 is to be installed in a restricted access location and in a Type “B” or “E” enclosure only. This device complies with Part 15 of the FCC rules. Operation is subject to the fol-...