ADTRAN DS3 NIU MTC Job Aid

Advertisement

Quick Links

DS3
GENERAL
DS3 NIU MTC
This job aid provides instructions for using the ADTRAN DS3 NIU Monitor
P/N 1212071L1
and Test Card (DS3 NIU MTC) to provide a quick, reliable means for craft
CLEI: NCC1SN0D
personnel to monitor and test both the network side and customer side data
loops. The DS3 MTC is compatible with any DS3 NIU3 chassis:
DS3 NIU Single Slot Housing
DS3 NIU 3-Slot Shelf
NIU3
DS3 NIU 12-Slot Shelf
1212071
ONLINE
Digital Network Loopback Test
The DS3 MTC inserts into any empty slot in the DS3 NIU chassis desig-
NTWK TO CUST
MON
nated for test. There are six front panel midsize connectors labeled as shown:
NTWK TO CUST MON
OUT FROM NTWK
OUT FROM
IN TO NTWK
NTWK
CUST TO NTWK MON
OUT FROM CUST
IN TO CUST
IN TO NTWK
The OUT FROM X test jacks receive network or customer data entering the
DS3 MTC and pass that data to the test device. The IN TO X test jacks inject
network or customer test signals from the test device into the DS3 MTC for
CUST TO NTWK
transmission into the respective loop. The MON jacks monitor the network-
MON
to-customer or customer-to-network loop.
A green ONLINE status LED verifies that the card has ±24 VDC or
OUT FROM
–48 VDC applied, and the cut-through relays are energized. If the LED is
CUST
off, the card does not have power, and the cut-through relays are de-ener-
gized. Cut-through relays are mounted separately on the housing, not on the
DS3 MTC.
IN TO CUST
The DS3 MTC is not intrusive during monitoring functions but is intrusive
and will disrupt data flow during testing functions.
INSTALLATION
After unpacking the unit, inspect it for damage. If damage is noted, file a
claim with the carrier, and then notify ADTRAN. See Warranty section.
Insert the card in the empty slot designated for test. Ensure the edge connec-
tor seats firmly into the backplane. Secure the card in place with the thumb-
screws.
C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
DS3 NIU Monitor and Test Card
ENVIRONMENTAL SPECIFICATIONS
Operating temperature: –40°C to +70°C
Storage temperature: –40°C to +85°C
Relative humidity: 95% noncondensing maximum
COMPLIANCE
NEBS Level 3
Meets FCC Part 15, Class A Requirements
Meets UL 60950 Requirements
The following table shows the compliance codes for the DS3 Monitor and
Test Card. The DS3 Monitor and Test Card is NRTL listed to the applicable
UL standards.
Compliance Code
Input
Power Code (PC)
F
Telecommunication Code (TC)
Installation Code (IC)
A
This device complies with Part 15 of the FCC rules. Operation is subject to
the following two conditions:
1.
This device may not cause harmful interference.
2.
This device must accept any interference received, including
interference that may cause undesired operation.
NOTE: Changes or modifications not expressly approved by ADTRAN could void
authority to operate this equipment.
61212071L1-22C
0406
Output

Advertisement

loading

Summary of Contents for ADTRAN DS3 NIU MTC

  • Page 1 This job aid provides instructions for using the ADTRAN DS3 NIU Monitor P/N 1212071L1 ♦ Storage temperature: –40°C to +85°C and Test Card (DS3 NIU MTC) to provide a quick, reliable means for craft CLEI: NCC1SN0D ♦ Relative humidity: 95% noncondensing maximum personnel to monitor and test both the network side and customer side data loops.