American Dynamics IP SpeedDome Ultra 8 Installation Manual

American dynamics speeddome ultra 8: installation guide
Hide thumbs Also See for IP SpeedDome Ultra 8:

Advertisement

Installation Guide

IP SpeedDome Ultra 8
Version 1.0
Part Number 8200-0885-01 A0

Advertisement

Table of Contents
loading

Summary of Contents for American Dynamics IP SpeedDome Ultra 8

  • Page 1: Installation Guide

    Installation Guide IP SpeedDome Ultra 8 Version 1.0 Part Number 8200-0885-01 A0...
  • Page 2 Boca Raton, FL 33487 U.S.A. Customer Service Thank you for using American Dynamics products. We support our products through an extensive worldwide network of dealers. The dealer through whom you originally purchased this product is your point of contact if you need service or support.
  • Page 3 Warnings To reduce risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Do not expose this appliance to rain or moisture. Do not install this product in hazardous areas where highly combustible or explosive products are stored or used.
  • Page 4 Installation Guide...
  • Page 5: Table Of Contents

    Tools Required ..........4-5 Attaching the Bubble to the IP SpeedDome Ultra 8 Unit ....4-8 Installing IP SDU8 with a ROENDC End Cap Preparing and installing the SDU8 Camera in an End Cap Assembly.
  • Page 6 Pin Outs for the IP SpeedDome Ultra 8 ....... 7-2...
  • Page 7: About This Guide

    This guide explains how to: • Prepare and assemble the IP SpeedDome Ultra 8 for installation. • Install the IP SpeedDome Ultra 8 into the supported housing structures. • Install the supported housing structures. This guide supersedes any existing SpeedDome Ultra 8 Install documentation.
  • Page 8: General Requirements

    General Requirements Have electrical work comply with all applicable local codes and ordinances. Verify existing site conditions and coordinate with the owner's representative and appropriate utilities as required. Obtain copies of all related plans, specifications, shop drawings and addenda to schedule and coordinate related work.
  • Page 9: Introduction

    Installation The IPSDU8 can be installed in the following ways: Indoor Hardmount, using a RHOPN pendant mount, and using a ROENDC End Cap assembly. Up to 16 IPSDU8s, supplying a maximum of 16 video inputs, can be connected to one Intellex IP unit, or up to 128 IPSDU8 units can be connected to one VideoEdge™...
  • Page 10: Installation Process

    Installation process Ensure the required power, network and alarm cables are installed and the network cable is labelled and disconnected at the network patch panel or access point. Remove the IPSDU8, dome camera and corresponding mount from their packaging. Referring to the IPSDU8 Installation Guide (8200-0885-01) install the following: •...
  • Page 11: Installing Ip Sdu8 With An Indoor Hardmount

    3 Installing IP SDU8 with an Indoor Hardmount Preparing and installing the Indoor Hardmount Housing Parts Required • RJ-45 connector • RJ-45 inline coupler adapter • 3 way power connector, 2109-0651-03 • 6 way alarm connector, 2109-0648-06 • 5 way alarm connector, 2109-0650-05 Note For installation to a tile ceiling, also order the UL-approved RH2x2 Metal Plate Mounting Kit.
  • Page 12 Hardmount. 5 Remove 2.5-3.8cm (1-1.5in) of jacket from the cable end(s) and install power and data connectors supplied. See Pin Outs for the IP SpeedDome Ultra 8 on page 7-2 for more details. Figure 3-2 Cabling the Hardmount cover 6 Pass the cable through the knockout hole in the hardmount cover as shown in Figure 3-2.
  • Page 13 Installing IP SDU8 with an Indoor Hardmount At this stage you should prepare the SDU8 Camera for connection to the housing. Note The SDU8 Camera’s default physical address is set to 001 and should not need to be changed. If this address is changed then you should ensure that a record of the new address is kept.
  • Page 14 Installing IP SDU8 with an Indoor Hardmount Base Tab Cap Tab Figure 3-4 Aligning the Cap and Base tabs 14 Turn the eyeball assembly clockwise until you hear a click. Figure 3-5 Locking the eyeball assembly 15 For ease of installation, adjust the two "swing out" mounting clips for ceiling thickness. Figure 3-6 Adjusting the mounting clips Using safety wire, attach the dome to a strong structural ceiling member as follows: Installation Guide...
  • Page 15 16 Find a strong structural member capable of supporting the dome. Warning Do not secure to any component of a fire control system. 17 Wrap one end of the wire around this member and twist the wire around itself four times to secure.
  • Page 16 21 Turn each of the two locking screws clockwise to fully extend the "swing out" mounting clips and to seat them tightly against the top surface of the ceiling. Figure 3-9 Securing the IP SDU8 with the Mounting clips 22 Apply power to dome. When power is applied, the dome checks its functionality by performing a homing routine during which the camera pans and then either goes to the start point of the "apple peel"...
  • Page 17 2 Place the large hole at the end of the lanyard over the screw head of the bubble and pull its end to snap it in place. Loop the lanyard to the inside of the housing. Figure 3-11 Attaching the bubble assembly 3 Center the bubble over the dome housing and align its tabs with the mating tabs in the housing.
  • Page 18 Installing IP SDU8 with an Indoor Hardmount Installation Guide...
  • Page 19: Installing Ip Speeddome Ultra 8 With A Rhopn Pendant Mounting

    4 Installing IP SpeedDome Ultra 8 with a RHOPN Assembly of the RHOPN Pendant Mount Parts Supplied • Support,10500-9641-01 • Cover, 10500-9588-01 • O-Ring, 12500-0022-07 • Screw, 20500-3494-01 • Retainer, 22852-0001-02 • Gasket, 10500-9801-01 • Install Kit, 0351-2119-01 • Anchor, M6, Wedge with hardware, 42880-0108-01 •...
  • Page 20 Procedure 4-1 Describes how to assemble the IP SpeedDome Ultra Camera RHOPN pendant mount. Procedure 4-1 Assembly of IP SpeedDome Ultra Camera 8 RHOPN Pendant Mount If mounting to a steel I-Beam, purchase I-Beam Mount RHIUIB. 1 To install the I-Beam Mount RHIUIB refer to instructions in the packaging then proceed to step 6.
  • Page 21 (F) other end. Insert straight pipe (F) into pipe tee (G). Figure 4-4 Attaching the housing 18 Slip cover (A) over the straight pipe (F), then thread the support (B) onto the pipe (F). Installing IP SpeedDome Ultra 8 with a RHOPN Pendant Mounting...
  • Page 22 21 Pass the cable through the top of the support and fold the incoming cables back on themselves. 22 Remove 2.5-3.8cm (1-1.5in) of jacket from the cable end(s) and install power and data connectors supplied. See Pin Outs for the IP SpeedDome Ultra 8 on page 7-2 for more details. Installation Guide...
  • Page 23: Preparing The Pendant Housing

    Tools Required • Screwdriver • Pliers • RJ-45 crimping tool Procedure 4-2 describes how to prepare the Pendant housing and attach the SpeedDome Ultra 8 camera. Procedure 4-2 Preparing the Pendant Housing and attaching the SpeedDome Ultra 8 Camera 1 Remove the pendant housing from the packaging.
  • Page 24 At this stage you should prepare the SpeedDome Ultra 8 Camera for connection to the pendant housing. 8 Gently swivel eyeball to totally expose one of two slot covers. Caution Swiveling the eyeball fast can damage gears. 9 Insert small, thin-bladed screwdriver into space between cover and eyeball.
  • Page 25 13 Connect the housing and eyeball assembly to the base by aligning the Cap and Base tabs. Figure 4-10 Aligning the Cap and Base tabs 14 Turn the eyeball assembly clockwise until you hear a click. Installing IP SpeedDome Ultra 8 with a RHOPN Pendant Mounting Figure 4-11 Locking the eyeball assembly Base tab...
  • Page 26: Attaching The Bubble To The Ip Speeddome Ultra 8 Unit

    Once the homing routine completes, affix the bubble to the dome as described in Procedure 4-3. Attaching the Bubble to the IP SpeedDome Ultra 8 Unit Procedure 4-3 describes how to attach the bubble assembly to the installed IP SpeedDome Ultra 8 unit.
  • Page 27 7 Refer to the User Guide (8200-0885-02) for instructions on configuring the IP SpeedDome Ultra 8 configuration settings. Installing IP SpeedDome Ultra 8 with a RHOPN Pendant Mounting Once the bubble is attached to the housing, surface A must meet surface B on all sides. Ensure lanyard is not caught between flange and trim ring gasket, or trim ring and sunshield.
  • Page 28 Installing IP SpeedDome Ultra 8 with a RHOPN Pendant Mounting 4-10 Installation Guide...
  • Page 29: Installing Ip Sdu8 With A Roendc End Cap

    5 Installing IP SDU8 with a ROENDC End Cap Preparing and installing the SDU8 Camera in an End Cap Assembly The ROENDC End Cap retrofits any existing outdoor SpeedDome® wall, pole, corner, or over-the- roof mount to accommodate the IP SDU8 housing. Figure 5-1 ROENDC End Cap Parts Supplied •...
  • Page 30: Preparing And Installing The Sdu8 Camera In An End Cap Assembly

    Preparing and installing the SDU8 Camera in an End Cap Assembly The ROENDC End Cap is designed to be used with the RHSOW short wall, RHOLW long wall, and the RHOTR over the rooof mounting kits. For information on installing these mounting kits see the relevant instructions provided in the packaging.
  • Page 31 Gasket (seat in groove at bottom of opening) Figure 5-4 Weatherproofing the End Cap assembly 4 Run cables from the existing pipe through the end cap and out its front. 5 Install the end cap as follows: a Align arrow on the adapter pipe with the mark at the top of the pipe assembly. Figure 5-5 Aligning the End Cap assembly b Maintaining arrow/line alignment, insert the End Cap assembly over the pipe until the rubber sleeve on the adapter pipe meets the circumference mark.
  • Page 32 Installing IP SDU8 with a ROENDC End Cap Check the level of the pipe assembly. If re-leveling is necessary, loosen the two set screws and repeat steps a-c above. Figure 5-8 Checking the pipe assembly’s levels 6 Remove the housing from the packaging. 7 Cut a 30cm (12in) length of Teflon tape.
  • Page 33 At this stage you should prepare the SDU8 Camera for connection to the pendant housing. Note The SDU8 Camera’s default physical address is set to 001 and should not need to be changed. If this address is changed then you should ensure that a record of the new address is kept. During the software installation ensure the dome configuration address is updated to match the domes physical address via the Live Video page on the Web GUI in order for camera control to be maintained.
  • Page 34 Figure 5-12 Inserting the desiccant bag into the housing Caution If the bubble is attached for up to 30 minutes or more and then detached, the bag must be replaced before the bubble is attached again. An extra bag is supplied. If more are needed, order kit 0352-0207- 21 Connect the housing and eyeball assembly to the base by aligning the Cap and Base tabs.
  • Page 35: Attaching The Bubble To The Ip Sdu8 Unit

    When power is applied, the dome checks its functionality by performing a homing routine during which the camera pans and then either goes to the start point of the "apple peel" pattern or if powered up once before, to the last position in memory. Once the camera stops, the camera is online and is ready to be controlled.
  • Page 36 Check for bent flange. Discard housing if found. Check for cracks in bubble. Discard bubble if found. 5 Use the drive (taped inside bubble) to tighten the four tamper-proof screws on the bubble assembly. 6 To compress the gasket evenly, tighten each screw in clockwise formation until slight resistance is felt, then retighten each screw again in clockwise formation until all screws are evenly tight.
  • Page 37: Restoring Factory Defaults

    The IPSDU8 has two physical recessed buttons, a Reset button and a Restore button. Refer to Figure 6-1 and Figure 7-1 for the location of the buttons. These buttons are only used during installation and commissioning of the unit and during fault finding; they are not intended to be used during normal operation when the camera is installed.
  • Page 38: Restoring Factory Defaults On The Ipsdu8

    Restoring factory defaults on the IPSDU8 The Restore button must be used in conjunction with the Reset button to restore the IPSDU8 to the factory defaults. Note The restore procedure only resets the web configuration pages to default. To reset the SDU8 to factory defaults follow the instructions in the SpeedDome Guide, 8200-0600-01.
  • Page 39: Technical Specifications

    Diagnostic LEDs LEDs on the underside of the mounting base enable you to check for power and data. Video LED (yellow) Power LED (green) Client LED (orange) Diagnostic LED Status Descriptions Power LED (green) On with repeating slow short flashes off – normal operation. Rapidly flashing –...
  • Page 40: Pin Outs For The Ip Speeddome Ultra 8

    Power On Self Test (POST) error. The number of rapid flashes indicates the actual error code. Pin Outs for the IP SpeedDome Ultra 8 The following tables give the pin out information for connecting the supplied connectors to the cabling.
  • Page 41: Alarm Connector Pin-Out For Indoor I/O Base

    Alarm connector pin-out for Indoor I/O base Alarm Out Connector is Black and Alarm in is White Figure 7-2 Indoor I/O base alarm connector pin-outs Alarm connector pin-out for Outdoor I/O base Alarm Out Connector is Black and Alarm in is White Figure 7-3 Outdoor I/O base alarm connector pin-out Technical Specifications...
  • Page 42 Technical Specifications Installation Guide...

Table of Contents