T
ROUBLESHOOTING

Trouble-Shooting Index

If you are experience problems while operating the Wedge, please use the following
table to locate possible causes and solutions before contacting Alesis customer
service for assistance.
Symptom
The display does not light
when the ON/OFF switch
is turned on.
Does not respond to MIDI
program changes or
modulation control.
No audio is heard.
Using the Wedge on a
mixer send and return,
thin, phasing sound on all
programs.
Cannot adjust an effect's
MIX parameter (displays
"- - -" instead of a number
from 0-100%).
Unit does not respond to
front panel controls.

Re-initializing

To re-initialize the Wedge, hold down both [PROG] and [BYPASS] while turning
on the power. This will reset all Utility parameters to their default settings, restore
all factory User Programs and will recall Preset
Wedge Reference Manual
C
7
HAPTER
Cause
No power.
MIDI channel is set to a
different number than
the controlling device.
Program Change receive
is disabled.
Bypass function is on
with Dry Defeat on.
Bypass function is on
with effect's MIX
parameter set to 0%.
Dry Defeat is turned off
Dry Defeat is turned on.
Unknown software
conflict, military
satellites, or static
electricity.
.
00
Troubleshooting – Chapter 7
Solution
Check that the power cable
is plugged in properly.
Go to UTILity page 2 and
move the [B] slider to
adjust the MIDI channel.
Go to UTILity page 2 and
move the [D] slider to turn
On MIDI PChg.
Press [UTIL] until Page 1 is
selected, then press [D] to
turn off Dry Defeat.
Use [EDIT] to locate the
effect's MIX parameter
and set it to 100% (if more
than one effect is used in
Configuration, adjust each
effects' MIX.)
Press [UTIL] until Page 1 is
selected, then press [D] to
turn on Dry Defeat.
Press [UTIL] until Page 1 is
selected, then press [D] to
turn off Dry Defeat.
Disconnect MIDI input.
Power down and power
up again. If this doesn't
work, try reinitialization.