Download Print this page

Aiphone LDF-20C User Manual

Ldf loudspeaker master station with external control capability

Advertisement

Quick Links

LDF Loudspeaker Master Station with External Control Capability
- LDF SUPPLEMENT TO LAF-C/CA INSTRUCTIONS -
The LDF Loudspeaker Intercom and External Control System is designed for communication between a central master
station and remote intercom stations. The LDF is an expanded feature version of the LAF-C/CA system. All
information regarding installation other than the external control functions is included in the LAF-C/CA instructions. In
addition to communication to remote locations, external devices can be activated, such as activating a CCTV camera
when the associated sub station is selected, selectively controlling the corresponding door strike or maglock, or both.
WIRING DIAGRAM:
LDF-20CA
1
2
3
~
20
E
-
External
Terminal Block
PS-12C
+
+
-
-
Individual Components for System:
LDF-nC
Master station with selective contact output capability (20, 40)
LDF-nCA
Master station w/handset and selective contact output capability (20, 40)
LD-20AS
20-call Add-on Selector with selective output capability
LD-40AS
40-call Add-on Selector with selective output capability
RY-PA
Relay for selective output (1 per station requiring external contact)
PS-12C
12V DC, 1A Power Supply
LE-series
Any model sub station with LE-prefix
LS-NVP
Vandal proof sub station (add SBX-NVP for surface mount)
IMPORTANT:
1.
RY-PA must be used for each additional contact to
isolate AC voltage from the intercom circuit.
2.
Extra contact connections and L are on separate
terminal block. LDF-40C/CA has two terminal blocks.
Pg. 1
LDF-20C
LDF-20CA
SYSTEM USED FOR CCTV CAMERA CALL-UP
LS-NVP
Red
Blk
Grn
RY-PA
1
YEL
BLK
#1
2
BLK
3
~
20
L
Equipment for each station that requires
both a constant closure and momentary
closure when a channel is selected:
2 RY-PA relays
2 Diodes (1N4001)
LDF
LDF-40C
LDF-40CA
LS-NVP
Red
Blk
Grn
Constant Closure for Station #1
RY-PA
YEL
Constant Closure for Station #2
#2
RY-PA
YEL
BLK
#3
Terminal Block
LE-DA
NOTE:
1
Leave jumper between E & - on master
and subs when using 2 conductor
E
homerun wiring IN SINGLE MASTER
-
SYSTEM ONLY. Jumper BLK/GRN
wires at LS-NVP in 2-wire system.
CONSTANT CLOSURE:
Normally Open contacts remain closed as
long as master has sub station selected.
Constant Closure for Station #3
DUAL FUNCTIONS FROM EACH CHANNEL:
RY-PA
1
BLK
#1
RY-PA
BLK
#2
L
2
LDF Master
+
-
LDF TERMINAL DEFINITIONS:
+
Positive 12V DC input, and constant closure output
-
Negative
1~40
Station number
E
Common communication
R
Occupied LED control
L
Positive output for selective closure
(Located on terminal block)
Specia l
Ord e r
Prod u c t s
YEL
Momentary closure #1
YEL
Constant closure #1
RY-PA
Momentary
YEL
BLK
#1
closure #2
RY-PA
Constant
BLK
YEL
#2
closure #2

Advertisement

loading

Summary of Contents for Aiphone LDF-20C

  • Page 1 RY-PA must be used for each additional contact to isolate AC voltage from the intercom circuit. Extra contact connections and L are on separate terminal block. LDF-40C/CA has two terminal blocks. Pg. 1 LDF-20C LDF-40C LDF-20CA LDF-40CA SYSTEM USED FOR CCTV CAMERA CALL-UP...
  • Page 2: Wiring Diagram

    2 common + 1 individual wire per sub station on wire run. Separate 2 conductor from RY-PA to external device. Shielded cable is recommended. Use Aiphone #822202 (2 cond., 22AWG) or #822203 (3 cond., 22AWG) wire. Wiring Distance: 650' with 22AWG; 1,600' with 18AWG.