NO
pict. 1
well-settled sand
and gravel filling
prefabricated pit
25x25x25cm approx (G/D1)
G/D2
30x30x30cm approx (
)
G/D3
40x40x40cm approx (
)
connection
accessory 4068964
support bricks
secured in place
with cement
pict. 2
2.5 mm (G/DM1)
8 mm (G/DM3)
frame
upper casing
level flushing
pict. 3
to roadside
. 4
TOP VIEW pict
G/DD
ORIENTING THE LIGHT BEAM
Caution: During the installation stage (drive-over or not), check that the fixture is
orientated
so that the light beam is directed in the desired way (pict. 4).
Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number that
recognizes the fixture.
Concord
Pathe G/DD2
Pathe G/DD3
Ø145
Ø 215
Ø 170
Ø 145
Ø270
Pathe G/DQ2
Pathe G/DQ3
Ø145
Ø 215
Ø 170
Ø 145
Ø270
YES
30 cm
(G/DM1)
35 cm
(G/DM3)
G/DQ
Dark zone
Lighted
zone
IS500
230-240V~ 50/60Hz
Features and meaning of the symbols shown on the label:
• lighting appliance for indoor and outdoor ground-recessed installation.
Capable of withstanding the load of motor vehicles with inflatable tyres pumped with
air, maximum weight static or dynamic: 2000Kg
Fixtures that can be utilized in all accessible areas, according to EN60598-2-13
Pedestrian
Ø215
20kN static load resistance.
version Class I
Pathe G/DD1
Pathe G/DD2
Pathe G/DD3
Pathe G/DQ1
Pathe G/DQ2
Ø215
Pathe G/DQ3
• Do not install in areas where snowplows are used.
recess box
EMBEDDED INSTALLATION WITHOUT PASSAGE OF VEHICLES
electric cables
for correct assembly, proceed as follows:
1) avoid positioning the fixture in areas of subsidence (pict.1) where dirt and stagnant
water can accumulate.
drainage foundations
made of sand and
Picture 2
gravel soaked to
2) make a suitably-sized hole (core) in the ground.
saturation, well
3) square the upper part of the hole by inserting a prefabricated pit of approximately
settled
25x25x25cm (G/D1), 30x30x30cm (G/D2) or 40x40x40cm (G/D3).
The upper edge of the pit must be about 2/3 cm (G/D1-2) or 3/4 cm (G/D3) higher
than
the surrounding ground to which it must be connected with an outer slope for the
run-off of water and to avoid the accumulation of dirt.
4) fill the core with a mixture of sand and gravel up to approximately 20cm (G/D1),
recess box
25cm (G/D2) or 35cm (G/D3) from the upper edge of the pit. Hose with plenty of
water until refusal and tamp the mixture in such a way as to form a compact and
homogenous draining layer.
connection
5) place four bricks with cement into the pit thus created in order to create a solid
accessory 4068964
foundation
electric cables
for the recess box, which should jut out with respect to the level of prefabricated
pit by approximately 2/3 cm.
6) backfill the pit around the casing with a mixture of well tamped and set sand and
concrete block
gravel, arranging the cables for the electrical connection of the fixture.
lean concrete
EMBEDDED INSTALLATION WITH PASSAGE OF VEHICLES
proceed as in the above points 1-2-3-4.
draining layer
5) refer to pict.3, Make a lean concrete mix onto which the foundation block can be
laid, taking care to leave a hole in the centre of at least 6cm (G/D1), 12cm (G/D2)
or 20cm (G/D3) in diameter for drainage. Provide for the passage of electrical wires.
6) insert the outer casing of the fixture into a concrete foundation block, batched at 200
kg of 325 type cement per cubic metre of mixture. The block must have a diameter
(or side) of not less than 30 cm. Line up carefully the upper edge of the outer casing
with the trampling level as per pict. 3.
Dark zone
ELECTRICAL CONNECTION
Important: the electrical connection must be carried out by a skilled electrician.
Important: in the case of damage of the appliance, there may be a reduction in the
degree of protection with consequent infiltration of water and loss of insulation.
Therefore, additional protection should be inserted into the electrical plant against
direct contacts (for example a high sensitivity differential switch). During installation,
fully respect the current rules on electrical systems.
Lighted
• For the electrical connection use a flexible <HAR> rubber cable cross-section
zone
1x1,5mm
2
.
The fixtures are complete with a piece of H05RN-F (G/D1) or H07RN-F (G/D2-3)
cable which is pre-connected and sealed. For a rapid and safe connection with the
electric line use the connector 4068964 or an equivalent system that guarantees at
least the IP67 degree.
• it is essential a frequent cleaning of the glass and of the outer surface of the fixture
to avoid build up of mud and dirtiness resulting in dangerous overheating due to
uncorrect light and heath dissipation.
• important: in the event of damage to the H07RN-F cable, breakage of the screen,
infiltration of water, the appliance cannot be used. Disconnect it from the mains
supply and contact our company or our sales organization for replacement/repair.
Feilo Sylvania Europe LTD
Avis Way, Newhaven East Sussex BN9 0ED UK
www.feilosylvania.com
over, with max. glass temp. of 75°C
IS13209A
IP
IP
66
67
tmax. glas Temp. ta 25°C
40° C
40° C
50° C
40° C
40° C
50° C
MI/1881-C - 1
a
ed
ISO
ISO
14001
9001
Environmental
Quality
Management
Management
EM 539002
FM 01687
© Concord Lighting Limited 09.17

Advertisement

loading

Summary of Contents for CONCORD Pathe G/DD Series

  • Page 1 Quality control: Should you have any complaint please get in touch with our company or its sales organization. Please give the number of your order as well as the serial number that recognizes the fixture. MI/1881-C - 1 Feilo Sylvania Europe LTD 14001 9001 Concord Environmental Quality Management Management Avis Way, Newhaven East Sussex BN9 0ED UK www.feilosylvania.com EM 539002 FM 01687 © Concord Lighting Limited 09.17...
  • Page 2 Feilo Sylvania Europe LTD 1400 1 900 1 En vi ronmental Qual ity Ma na ge me nt Ma na ge me nt Avis Way, Newhaven East Sussex BN9 0ED UK EM 539002 FM 01687 © Concord Lighting Limited 09.17 www.feilosylvania.com...

This manual is also suitable for:

Pathe g/dq seriesPathe g/dd1Pathe g/dd2Pathe g/dd3Pathe g/dq1Pathe g/dq2 ... Show all