Before operating this unit please read this manual thoroughly. Retain this manual for future reference! The Battery module may only installed and put into operation by qualified personnel.
Description and intended Use:
The 12V 7Ah battery module consists of a battery receptacle suitable for DIN-Rail or panel/ wall mounting, one 12V maintenance-free valve regulated lead acid (VRLA) battery, a set of cables with a
heavy duty in-line fuse holder, two fuses (one as a spare) and a terminal to connect the battery module to the DC-UPS UB10.241 or the similar.
This device is intended for the general use such as in industrial control, office, communication, and instrumentation equipment. Do not use this device in aircrafts, trains and nuclear equipment
where malfunction of the power supply may cause severe personal injury or threaten human life.
Instructions for Use and Disposal of the Battery
(1) Place the battery module outside the cabinet or in the coolest area, when used inside the cabinet.
2
(2) Use wires not smaller than 2.5mm
(3) Disconnect battery fuse before working on the battery or on the DC-UPS.
(4) To replace battery, loosen screws with only one turn and slide the fixing bracket left to lift it up.
(5) For storage, installation and operation, the requirements of the EN 50272-2 as well as other national regulations must be observed.
(6) Ensure sufficient ventilation for the battery.
(7) Always dispose the batteries through a recycling organization. Batteries must be completely discharged before recycling.
The information presented in this document is believed to be accurate and reliable and may change without notice. The English text applies in cases of doubt.
Vor Inbetriebnahme lesen !
Bitte lesen Sie diese Warnungen und Hinweise sorgfältig durch, bevor Sie dieses Batteriemodul in Betrieb nehmen. Bewahren Sie die Anleitung zum Nachlesen auf. Das Batteriemodul darf nur
durch fachkundiges und qualifiziertes Personal installiert werden.
Dieses 12V 7,0Ah Batteriemodul besteht aus einem Gestell, welches entweder an eine DIN-Schiene geschnappt oder direkt auf eine flache Oberfläche geschraubt werden kann. In diesem Gestell
befindet sich eine wartungsfreie 12V VRLA Batterie mit einem Kabelsatz, einem Sicherungshalter für Flachsicherungen, zwei Sicherungen (eine als Ersatz) und einem Anschlussblock zum
Anschließen an die DC-USV UB10.241 oder der Gleichen.
Bestimmungsgemäßer Gebrauch:
Dieses Batteriemodul ist zur Verwendung für allgemeine elektronische Geräte, wie z.B. Industriesteuerungen, Bürogeräte, Kommunikationsgeräte oder Messgeräte geeignet. Benutzen Sie dieses
Gerät nicht in Steuerungsanlagen von Flugzeugen, Zügen oder atomaren Einrichtungen, in denen eine Funktionsstörung zu schweren Verletzungen führen oder Lebensgefahr bedeuten kann.
Anleitung zum Gebrauch und zur Entsorgung der Batterie!
(1) Verwenden Sie das Batteriemodul außerhalb des Schaltschrankes oder an der kühlsten Stelle innerhalb des Schaltschrankes.
(2) Verwenden Sie Anschlussdrähte nicht kleiner als 2.5mm
(3) Entfernen Sie die Batteriesicherung bevor Sie am Batteriemodul oder an der DC-USV arbeiten oder Veränderungen durchführen.
(4) Um die Batterie auszuwechseln, lockern Sie die beiden oberen Schrauben mit einer Umdrehung und schieben Sie den Haltebügel nach links, damit er nach vorne klappen kann.
(5) Bei Lagerung, Installation und Betrieb sind die Anforderungen aus der EN 50727-2 sowie eventuelle nationale Regeln zu befolgen.
(6) Stellen Sie eine gute Belüftung für die Batterie sicher.
(7) Verbrauchte Batterien sind über zugelassene Recycling Stellen zu entsorgen. Hierzu müssen die Batterien komplett entladen abgegeben werden.
Die angegebenen Daten dienen allein der Produktbeschreibung und sind nicht als zugesicherte Eigenschaften im Rechtssinne aufzufassen. Im Zweifelsfall gilt der englische Text.
Order Numbers:
Bestellnummern:
UZK12.071
Battery module
UZO12.07
Battery module without battery
UZB12.071
Battery replacement
Technical Data
Maintenance free valve regulated lead acid battery
Design life acc. to Eurobat [years]
Self discharge / month at 20°C ambient temperature
Dimensions (width x height x depth), without DIN-rail
Use DIN-rails according to EN 60715 or EN 50022 with a height of 7.5
or 15mm.
Weight
Operational ambient temperature
Non-operational ambient temperature
Relative humidity (
Do not energize while condensation is present
Class of protection
Terminals and Wiring:
Solid wires
Stranded wires
AWG sizes
Wire stripping length
Recommended tightening torque
Recommended screwdriver (slotted)
Fuse
The battery fuse protects the wires between the battery module and the DC-UPS. Furthermore, it
allows the disconnection of the battery from the DC-UPS, which is recommended, when working
on the battery or DC-UPS.
Use only blade-terminal-fuses rated with 30A type ATO
One spare fuse is included in the shipment.
Warranty
3 years except battery. Battery is considered as a service part. Special conditions are part of our
general terms and conditions.
Do not store the battery longer than 9 month, performance might change.
12V 7Ah Battery module
12V 7Ah Batterie Modul
12V 7Ah Pack batterie
12V 7Ah Kit batteria
12V 7Ah Módulo de bateria
(or 12 AWG) and not longer than 2x1.5m (cord length 1.5m).
2
(oder 12 AWG) und nicht länger als 2x1.5m (Kabellänge 1.5m).
Batterie Modul
Batterie Modul ohne Batterie
Ersatzbatterie
Technische Daten
Wartungsfreie Bleisäure Batterie
Lebensdauer nach Eurobat [Jahre]
Selbstentladung / Monat bei 20°C Umgebungstemperatur
Abmessungen (Breite x Höhe x Tiefe), ohne DIN-Schiene
DIN-Schienen gemäß EN 60715 oder EN 50022 mit einer Höhe
von 7,5 oder 15mm sind zu verwenden.
Gewicht
Arbeitstemperaturbereich
Lager- und Transporttemperaturbereich
)
Relative Luftfeuchtigkeit (
aufweist
Schutzklasse
Anschlussklemmen und Verdrahtung
Starrdrähte
Flexible Anschlussleitungen
AWG Größen
Abisolierlänge
Empfohlenes Anzugsmoment
Empfohlener Schlitz-Schraubendreher
®
257 030 from Littelfuse.
Nicht betreiben solange das Gerät Kondensation
)
Sicherung
Die Batteriesicherung schützt die Leitung zwischen Batteriemodul und der DC-USV.
Außerdem erlaubt sie die Trennung von Batteriemodul und DC-USV, welches bei Arbeiten an
dieser oder der Batterie empfohlen wird.
Verwenden Sie ausschließlich 30A Sicherungen vom Typ ATO
Eine Ersatzsicherung liegt bei.
Garantiebedingungen
3 Jahre, ausgenommen Batterie. Batterien sind Verschleißteile, für die spezielle Bedingungen
gelten. Diese entnehmen Sie bitte aus unseren AGB.
Die Batterie nicht länger als 9 Monate lagern, die Daten könnten sich ändern.
UZK12.071, UZB12.071, UZO12.07
nom.
12V, 7Ah
3-5
typ.
3%
nom.
155x124x112mm / 6.1''x 4.88''x4.41''
max.
3200g / 7.06lb
> 0°C, < +40°C,
> -20°C, < +50°C
> 5%, < 95% RH
III
nom.
2.5-4mm
nom.
2.5-4mm
nom.
12 AWG
nom.
7mm / 0.275"
nom.
0.8Nm / 7lb.in
nom.
3.5mm
®
English
Deutsch
2
2
257 030 der Firma Littelfuse.

Advertisement

loading

Summary of Contents for Pulse DIMENSION UZK12.071

  • Page 1 Instruction Manual 12V 7Ah Battery module Bedienungsanleitung 12V 7Ah Batterie Modul Manual d'instructions 12V 7Ah Pack batterie Manual de instrucciones 12V 7Ah Módulo de batería Manuale di Istruzione 12V 7Ah Kit batteria Manual de Instruções 12V 7Ah Módulo de bateria UZK12.071, UZB12.071, UZO12.07 Read first ! English...
  • Page 2 12V, 7Ah Battery Module Instruction Manual 12V, 7Ah Batterie Modul Bedienungsanleitung Dimensions Front view/ Frontansicht Side view/ Seitenansicht Panel/ wall mounting Wandbefestigung Panel/ wall mounting is possible by detaching the DIN-Rail Brackets: Wandbefestigung ist durch Entfernen der DIN-Schienen-Befestigung möglich: Detach the two aluminum brackets by removing the two Remove the plastic lock mechanism by using a flat-blade Panel/ wall mounting is possible by using either the four screws with a Torx screwdriver (Torx 10)