INSTRUCTION SHEET
B18 Series
Combination Box and/or Conduit/Cable Hangers from
Drop Wire/Rod and Beam
Fig. 1
Fig. 4
Fig. 6
Fig. 8
WARNING:
1.
Pentair products shall be installed and used only as indicated in Pentair product instruction sheets and training materials. Instruction sheets are available at
www.erico.pentair.com and from your Pentair customer service representative.
2.
PENTAIR products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings.
3.
All instructions must be completely followed to ensure proper and safe installation and performance.
4.
Improper installation, misuse, misapplication or other failure to completely follow Pentair's instructions and warnings may cause product malfunction, property
damage, serious bodily injury and/or death, and void your warranty.
5.
Products that are manufactured using spring steel components shall be used only in a non-corrosive indoor environment.
6.
All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any
other purpose.
NOTE: All load ratings are for static conditions and do not account for dynamic loading such as wind, water or seismic loads, unless otherwise noted.
The customer is responsible for:
a. Conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified
engineer.
c. Using appropriate industry standard hardware as noted above.
SAFETY INSTRUCTIONS:
All governing codes and regulations and those required by the job site must be observed.
Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the application.
Pentair, CADDY, ERICO CADWELD, ERICO CRITEC, ERICO, ERIFLEX, and LENTON are owned by Pentair or its global affiliates. All other trademarks
are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.
TECHNICAL SUPPORT:
www.erico.pentair.com
Fig. 2
Fig. 3
Fig. 5
Fig. 7
Note:
Fig. 9
1.
2.
3.
CFS223_J
1 OF 4
Global Part
Fig.
Number
6MB18
1
812MB18
1 1/2" [13] & 3/4" [19]
16MB18
1
MCS50B18
6
MCS100B18
6
6M3B18CO
8
6MB186
1
812MB186
1
16MB186
1
812MB188Z
1 1/2" [13] & 3/4" [19]
6MB1824
4
812MB1824
4 1/2" [13] & 3/4" [19]
16MB1824
4
6MB1858
4
812MB1858
4 1/2" [13] & 3/4" [19]
16MB1858
4
812MB18912
4 1/2" [13] & 3/4" [19]
6MB18A
2
812MB18A
2 1/2" [13] & 3/4" [19]
16MB18A
2
MCS50B18A
7
6M3B18ACO
9
812MB18S
3 1/2" [13] & 3/4" [19]
Factory riveted assembly for multiple conduit
*(XXX)CO
5
SMS8
-
Self tapping screws for mounting box to bar.
* To order with B18CO, add the suffix "CO" to the
above part number. Additional conduit clips with
thread impression use the 4I extension. (EX. 812M4I)
May require dedicated drop wire/rod - consult local authority.
Product intended for single and multiple runs of conduit.
For single runs, extra leg may be bent of removed if needed.
When mounting box to B18 Bar and using screws, such as
CADDY SMS8, two screws are required. When supporting the
CADDY B18 series with threaded rod going through both
the B18 and the box, this single support is appropriate.
Additional screws are not necessary.
© 1998-2017 Pentair All Rights Reserved
Sizing Chart
Conduit/Cable
Installation Attachment
MC/AC
Attaches to #12 wire
1" [25]
through 1/4" [6] rod or
1/8" [3] through
MC/AC
flange.
MC/AC
MC/AC
MC/AC
Attaches to 3/8" [10]
plain or threaded rod or
1/2" & 3/4"
1/4" [6] through 3/8" [10]
flange.
1" [25]
Attaches to 1/2" [13] &
5/8" [16] threaded rod
MC/AC
Attaches to 1/8" [3]
through 1/4" [6] flange.
1" [25]
MC/AC
Attaches to 5/16" [8]
though 1/2" [13] flange.
1" [25]
9/16" [14] though 3/4"
[19] flange
MC/AC
1/4" [6] center hole for
1" [25]
screw or threaded rod
mount.
MC/AC
MC/AC
1/4-20 x 5/8" [16] stud.
clips, mounting plate and oneclip, factory
riveted. Additional conduit clips ordered
seperately.
1/4" [6]

Advertisement

loading

Summary of Contents for Pentair CADDY B18 Series

  • Page 1 Pentair customer service representative. PENTAIR products must never be used for a purpose other than the purpose for which they were designed or in a manner that exceeds specified load ratings. All instructions must be completely followed to ensure proper and safe installation and performance.
  • Page 2 MCS100 holds approximately 8 cables. Pentair, CADDY, ERICO CADWELD, ERICO CRITEC, ERICO, ERIFLEX, and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.
  • Page 3 Pentair, CADDY, ERICO CADWELD, ERICO CRITEC, ERICO, ERIFLEX, and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.
  • Page 4 Pentair, CADDY, ERICO CADWELD, ERICO CRITEC, ERICO, ERIFLEX, and LENTON are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice.

This manual is also suitable for:

Caddy 6mb18Caddy 812mb18Caddy 16mb18Caddy mcs50b18Caddy mcs100b18Caddy 6m3b18co ... Show all